124 research outputs found
Maxillary Sinus Augmentation With Recombinant Human Bone Morphogenetic Proteinâ 2 and Particulate Allograft Without an Absorbable Sponge: A Case Report
Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/141930/1/cap0175.pd
Planning and treatment in oral rehabilitation with implant-supported prostheses using cephalometric analysis
Comparison of different methods involved in the planning of clinical crown lengthening surgery
There is little material in the literature that compares biological width measurements in periapical and bite-wings radiographs with clinical measurements. The purpose of this study was to compare measurements of biological width taken by three different methods which are frequently used for planning periodontal surgery - periapical radiograph, bite-wing radiograph and transperiodontal probing - with the trans-surgical measurements. Thirty-four sites from twenty-one subjects were analyzed. The intra-class correlation coefficients between measurements obtained trans-surgically (gold standard) and those obtained by transperiodontal probing, periapical radiography and bite-wing radiography were determined. Average measurements were compared using the Wilcoxon test at a significance level of 0.05. Also, the frequency distribution of differences between test measurements and the gold standard was calculated. The results showed that transperiodontal probing (mean 2.05 mm) was the most accurate measurement, as compared to the gold standard (mean 1.97 mm), with no statistically significant difference observed. On the other hand, periapical and bite-wing radiographic mean values (1.56 mm and 1.72 mm, respectively) were smaller than the gold standard, with statistically significant differences (p < 0.05). It was concluded that transperiodontal probing was the most accurate measurement, as compared to the gold standard, followed by that obtained with the bite-wing radiograph. The clinical relevance of these results could be that planning for crown lengthening surgery should, preferably, include transperiodontal probing
Missense and nonsense mutations in melanocortin 1 receptor (MC1R) gene of different goat breeds: association with red and black coat colour phenotypes but with unexpected evidences
<p>Abstract</p> <p>Background</p> <p><it>Agouti </it>and <it>Extension </it>loci control the relative amount of eumelanin and pheomelanin production in melanocytes that, in turn, affects pigmentation of skin and hair. The <it>Extension </it>locus encodes the melanocortin 1 receptor (MC1R) whose permanent activation, caused by functional mutations, results in black coat colour, whereas other inactivating mutations cause red coat colour in different mammals.</p> <p>Results</p> <p>The whole coding region of the <it>MC1R </it>gene was sequenced in goats of six different breeds showing different coat colours (Girgentana, white cream with usually small red spots in the face; Maltese, white with black cheeks and ears; Derivata di Siria, solid red; Murciano-Granadina, solid black or solid brown; Camosciata delle Alpi, brown with black stripes; Saanen, white; F<sub>1 </sub>goats and the parental animals). Five single nucleotide polymorphisms (SNPs) were identified: one nonsense mutation (p.Q225X), three missense mutations (p.A81V, p.F250V, and p.C267W), and one silent mutation. The stop codon at position 225 should cause the production of a shorter MC1R protein whose functionality may be altered. These SNPs were investigated in a larger sample of animals belonging to the six breeds. The Girgentana breed was almost fixed for the p.225X allele. However, there was not complete association between the presence of red spots in the face and the presence of this allele in homozygous condition. The same allele was identified in the Derivata di Siria breed. However, its frequency was only 33%, despite the fact that these animals are completely red. The p.267W allele was present in all Murciano-Granadina black goats, whereas it was never identified in the brown ones. Moreover, the same substitution was present in almost all Maltese goats providing evidence of association between this mutation and black coat colour.</p> <p>Conclusion</p> <p>According to the results obtained in the investigated goat breeds, <it>MC1R </it>mutations may determine eumelanic and pheomelanic phenotypes. However, they are probably not the only factors. In particular, the surprising not complete association of the nonsense mutation (p.Q225X) with red coat colour raises a few hypotheses on the determination of pheomelanic phenotypes in goats that should be further investigated.</p
Assessment of Marginal Bone Loss around Platform-Matched and Platform-Switched Implants - A Prospective Study
Abstract The aim of the present study was to perform a software-assisted radiographic assessment of the effect of platform-switching on marginal bone loss (MBL) around dental implants. Forty patients requiring a dental implant in non-grafted partially edentulous mandibles were enrolled and categorized into implants receiving a platform-matched abutment (control group) or implants with a platform-switched abutment (test group). Standardized digital periapical radiographs were taken at the time of implant placement (T0), at implant loading (T1) and 1-year after functional loading (T2). Software-assisted radiographic assessment of the MBL horizontal, vertical and area changes was performed and compared between time intervals (T1-T0, T2-T1 and T2-T0). Mean radiographic horizontal MBL (hMBL) and vertical MBL (vMBL) from implant placement to 1-year after implant loading (T2-T0) were significantly increased around platform-matched when compared to platform-switched abutments (1.04 mm vs 0.84 mm, p<0.05) and (0.99 mm vs 0.82 mm, p<0.05), respectively. Additionally, bone loss area (BLa) was greater (0.77 mm2 vs 0.63 mm2; p<0.05) for platform-matched compared to platform-switched abutments. Platform-switching has a positive impact upon the amount of bone modeling after loading implants with internal hexagon connection
Does the number of implants have any relation with peri-implant disease?
Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1) ≤5 implants and G2) >5 implants. Data collection included modified plaque index (MPi), bleeding on probing (BOP), probing depth (PD), width of keratinized mucosa (KM) and radiographic bone loss (BL). Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL) and Mann-Whitney test for categorical variables (MPi and BOP). KM and BL showed statistically significant differences between both groups (p<0.001). Implants from G1 – 19 (20.43%) – compared with G2 – 26 (38.24%) – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210). Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis
Soft tissue behavior around dental implants placed in fresh extraction sockets and immediately restored in esthetic area: a preliminary short-term evaluation
- …
