916 research outputs found

    Continuous heating of a giant X-ray flare on Algol

    Get PDF
    Giant flares can release large amounts of energy within a few days: X-ray emission alone can be up to ten percent of the star's bolometric luminosity. These flares exceed the luminosities of the largest solar flares by many orders of magnitude, which suggests that the underlying physical mechanisms supplying the energy are different from those on the Sun. Magnetic coupling between the components in a binary system or between a young star and an accretion disk has been proposed as a prerequisite for giant flares. Here we report X-ray observations of a giant flare on Algol B, a giant star in an eclipsing binary system. We observed a total X-ray eclipse of the flare, which demonstrates that the plasma was confined to Algol B, and reached a maximum height of 0.6 stellar radii above its surface. The flare occurred around the south pole of Algol B, and energy must have been released continously throughout its life. We conclude that a specific extrastellar environment is not required for the presence of a flare, and that the processes at work are therefore similar to those on the Sun.Comment: Nature, Sept. 2 199

    Insights into the role of 3-O-sulfotransferase in heparan sulfate biosynthesis

    Get PDF
    3-O-Sulfotransferase enzyme (sHS) from Litopenaeus vannamei was cloned and its substrate specificity was investigated against a number of GAG structures, including modified heparin polysaccharides and model oligosaccharides. For the heparin polysaccharides, derived from porcine intestinal mucosa heparin, sulfate groups were incorporated into glucosamine residues containing both N-sulfated and N-acetylated substitution within the regions of the predominant repeating disaccharide, either I–ANS or I–ANAc. However, the resulting polysaccharides did not stabilize antithrombin, which is correlated with anticoagulant activity. It was also shown that the enzyme was able to sulfate disaccharides, I2S–ANS and G–ANAc. The results further illustrate that 3-O-sulfation can be induced outside of the classical heparin-binding pentasaccharide sequence, show that 3-O-sulfation of glucosamine is not a sufficient condition for antithrombin stabilization and suggest that the use of this enzyme during HS biosynthesis may not occur as the final enzymatic step

    Relationship between nano-architectured Ti1−xCux thin film and electrical resistivity for resistance temperature detectors

    Get PDF
    Ti1−xCux thin films were produced by the glancing angle deposition technique (GLAD) for resistance temperature measurements. The deposition angle was fixed at α = 0° to growth columnar structures and α = 45° to growth zigzag structures. The Ti-to-Cu atomic concentration was tuned from 0 to 100 at.% of Cu in order to optimize the temperature coefficient of resistance (TCR) value. Increasing the amount of Cu in the Ti1−xCux thin films, the electrical conductivity was gradually changed from 4.35 to 7.87 × 105 Ω−1 m−1. After thermal “stabilization,” the zigzag structures of Ti1−xCux films induce strong variation of the thermosensitive response of the materials and exhibited a reversible resistivity versus temperature between 35 and 200 °C. The results reveal that the microstructure has an evident influence on the overall response of the films, leading to values of TCR of 8.73 × 10−3 °C−1 for pure copper films and of 4.38 × 10−3 °C−1 for a films of composition Ti0.49Cu0.51. These values are very close to the ones reported for the bulk platinum (3.93 × 10−3 °C−1), which is known to be one of the best material available for these kind of temperature-related applications. The non-existence of hysteresis in the electrical response of consecutive heating and cooling steps indicates the viability of these nanostructured zigzag materials to be used as thermosensitive sensors.Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Funding UID/FIS/04650/2013 and Project PTDC/EEI-SII/5582/2014. A. Ferreira and C. Lopes thanks the FCT for Grant SFRH/BPD/102402/2014 and SFRH/BD/103373/2014. The authors thank financial support from the Basque Government Industry Department under the ELKARTEK Programinfo:eu-repo/semantics/publishedVersio

    Underlying Factors Associated with Anemia in Amazonian Children: A Population-Based, Cross-Sectional Study

    Get PDF
    Background: Although iron deficiency is considered to be the main cause of anemia in children worldwide, other contributors to childhood anemia remain little studied in developing countries. We estimated the relative contributions of different factors to anemia in a population-based, cross-sectional survey. Methodology: We obtained venous blood samples from 1111 children aged 6 months to 10 years living in the frontier town of Acrelandia, northwest Brazil, to estimate the prevalence of anemia and iron deficiency by measuring hemoglobin, erythrocyte indices, ferritin, soluble transferrin receptor, and C-reactive protein concentrations. Children were simultaneously screened for vitamin A, vitamin B-12, and folate deficiencies; intestinal parasite infections; glucose-6-phosphate dehydrogenase deficiency; and sickle cell trait carriage. Multiple Poisson regression and adjusted prevalence ratios (aPR) were used to describe associations between anemia and the independent variables. Principal Findings: The prevalence of anemia, iron deficiency, and iron-deficiency anemia were 13.6%, 45.4%, and 10.3%, respectively. Children whose families were in the highest income quartile, compared with the lowest, had a lower risk of anemia (aPR, 0.60; 95% CI, 0.37-0.98). Child age (<24 months, 2.90; 2.01-4.20) and maternal parity (>2 pregnancies, 2.01; 1.40-2.87) were positively associated with anemia. Other associated correlates were iron deficiency (2.1; 1.4-3.0), vitamin B-12 (1.4; 1.0-2.2), and folate (2.0; 1.3-3.1) deficiencies, and C-reactive protein concentrations (>5 mg/L, 1.5; 1.1-2.2). Conclusions: Addressing morbidities and multiple nutritional deficiencies in children and mothers and improving the purchasing power of poorer families are potentially important interventions to reduce the burden of anemia.Sao Paulo State Research Agency [FAPESP 07/53042-1]Sao Paulo State Research AgencyNational Research Agency of BrazilNational Research Agency of Brazil [CNPq 470573/2007-4

    Is Ankyrin a genetic risk factor for psychiatric phenotypes?

    Get PDF
    Background Genome wide association studies reported two single nucleotide polymorphisms in ANK3 (rs9804190 and rs10994336) as independent genetic risk factors for bipolar disorder. Another SNP in ANK3 (rs10761482) was associated with schizophrenia in a large European sample. Within the debate on common susceptibility genes for schizophrenia and bipolar disorder, we tried to investigate common findings by analyzing association of ANK3 with schizophrenia, bipolar disorder and unipolar depression. Methods We genotyped three single nucleotide polymorphisms (SNPs) in ANK3 (rs9804190, rs10994336, and rs10761482) in a case-control sample of German descent including 920 patients with schizophrenia, 400 with bipolar affective disorder, 220 patients with unipolar depression according to ICD 10 and 480 healthy controls. Sample was further differentiated according to Leonhard's classification featuring disease entities with specific combination of bipolar and psychotic syndromes. Results We found no association of rs9804190 and rs10994336 with bipolar disorder, unipolar depression or schizophrenia. In contrast to previous findings rs10761482 was associated with bipolar disorder (p = 0.015) but not with schizophrenia or unipolar depression. We observed no association with disease entities according to Leonhard's classification. Conclusion Our results support a specific genetic contribution of ANK3 to bipolar disorder though we failed to replicate findings for schizophrenia. We cannot confirm ANK3 as a common risk factor for different diseases

    Heterogeneity of fractional anisotropy and mean diffusivity measurements by in vivo diffusion tensor imaging in normal human hearts

    Get PDF
    Background: Cardiac diffusion tensor imaging (cDTI) by cardiovascular magnetic resonance has the potential to assess microstructural changes through measures of fractional anisotropy (FA) and mean diffusivity (MD). However, normal variation in regional and transmural FA and MD is not well described. Methods: Twenty normal subjects were scanned using an optimised cDTI sequence at 3T in systole. FA and MD were quantified in 3 transmural layers and 4 regional myocardial walls. Results: FA was higher in the mesocardium (0.46 ±0.04) than the endocardium (0.40 ±0.04, p≤0.001) and epicardium (0.39 ±0.04, p≤0.001). On regional analysis, the FA in the septum was greater than the lateral wall (0.44 ±0.03 vs 0.40 ±0.05 p = 0.04). There was a transmural gradient in MD increasing towards the endocardium (epicardium 0.87 ±0.07 vs endocardium 0.91 ±0.08×10-3 mm2/s, p = 0.04). With the lateral wall (0.87 ± 0.08×10-3 mm2/s) as the reference, the MD was higher in the anterior wall (0.92 ±0.08×10-3 mm2/s, p = 0.016) and septum (0.92 ±0.07×10-3 mm2/s, p = 0.028). Transmurally the signal to noise ratio (SNR) was greatest in the mesocardium (14.5 ±2.5 vs endocardium 13.1 ±2.2, p<0.001; vs epicardium 12.0 ± 2.4, p<0.001) and regionally in the septum (16.0 ±3.4 vs lateral wall 11.5 ± 1.5, p<0.001). Transmural analysis suggested a relative reduction in the rate of change in helical angle (HA) within the mesocardium. Conclusions: In vivo FA and MD measurements in normal human heart are heterogeneous, varying significantly transmurally and regionally. Contributors to this heterogeneity are many, complex and interactive, but include SNR, variations in cardiac microstructure, partial volume effects and strain. These data indicate that the potential clinical use of FA and MD would require measurement standardisation by myocardial region and layer, unless pathological changes substantially exceed the normal variation identified

    Quantitative image analysis of polyhydroxyalkanoates inclusions from microbial mixed cultures under different SBR operation strategies

    Get PDF
    Polyhydroxyalkanoates (PHAs) produced from mixed microbial cultures (MMC), regarded as potential substitutes of petrochemical plastics, can be found as intracellular granules in various microorganisms under limited nutrient conditions and excess of carbon source. PHA is traditionally quantified by laborious and time-consuming chromatography analysis, and a simpler and faster method to assess PHA contents from MMC, such as quantitative image analysis (QIA), is of great interest. The main purpose of the present work was to upgrade a previously developed QIA methodology (Mesquita et al., 2013a, 2015) for MMC intracellular PHA contents quantification, increase the studied intracellular PHA concentration range and extend to different sequencing batch reactor (SBR) operation strategies. Therefore, the operation of a new aerobic dynamic feeding (ADF) SBR allowed further extending the studied operating conditions, dataset, and range of the MMC intracellular PHA contents from the previously reported anaerobic/aerobic cycle SBR. Nile Blue A (NBA) staining was employed for epifluorescence microscope visualization and image acquisition, further fed to a custom developed QIA. Data from each of the feast and famine cycles of both SBR were individually processed using chemometrics analysis, obtaining the correspondent partial least squares (PLS) models. The PHA concentrations determined from PLS models were further plotted against the results obtained in the standard chromatographic method. For both SBR the predicted ability was higher at the end of the feast stage than for the famine stage. Indeed, an independent feast and famine QIA data treatment was found to be fundamental to obtain the best prediction abilities. Furthermore, a promising overall correlation (R2 of 0.83) could be found combining the overall QIA data regarding the PHA prediction up to a concentration of 1785.1 mgL-1 (37.3 wt%). Thus, the results confirm that the presented QIA methodology can be seen as promising for estimating higher intracellular PHA concentrations for a larger reactors operation systems and further extending the prediction range of previous studies.This study was supported by the Portuguese Foundation for Science and Technology (FCT) under the scope of the strategic funding of UID/BIO/04469/2013 unit and COMPETE 2020 (POCI-01-0145-FEDER-006684) and BioTecNorte operation (NORTE01-0145-FEDER-000004) funded by European Regional Development Fundunder the scope ofNorte2020 - ProgramaOperacional Regional do Norte.The authors also acknowledge the financial support to Cristiano S. Leal (PTDC/EBB-EBI/103147/2008, FCOMP-01-0124-FEDER009704) and Daniela P. Mesquita through the FCT postdoctoral grant (SFRH/BPD/82558/2011).info:eu-repo/semantics/publishedVersio

    Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization

    Get PDF
    The original Riva-Rocci method to measure blood pressure (BP) using a cuff at the upper arm assumed the pressure obtained by this technique was a good proxy for central aortic BP.1,2 The clinical (prognostic) importance of brachial cuff BP is undeniable for both the assessment of cardiovascular risk associated with elevated BP and the benefits of treatment-induced BP reduction.3 However, it is also generally appreciated that peripheral artery systolic BP (SBP; brachial or radial artery) may be an inaccurate substitute for central SBP.4 This has been reported in human studies using intra-arterial catheterization of peripheral and central arteries.5–8 There may also be a discrepancy between peripheral and central BP responses to vasoactive drugs.9 These findings are corroborated in larger studies using non-invasive central aortic BP methods,10–13 and, while yet to be fully adopted in clinical practice, an independent prognostic value of central BP has been demonstrated.14–16 Altogether, there is a growing interest among clinicians towards improving risk estimates by using devices that provide more accurate measures of central aortic BP than those provided by current brachial cuff BP methods. Many non-invasive devices have been developed that purport to estimate central BP from different peripheral artery sites (e.g. radial, brachial, carotid arteries) using different principles of recording the pressure or surrogate signals (e.g. applanation tonometry, oscillometry, ultrasound, or magnetic resonance imaging) and different calibration methods to derive central BP. Since upper arm cuff-based devices to estimate central BP are more clinically appealing, in recent years several companies have developed such devices using a variety of techniques (e.g. oscillometric sub-diastolic or supra-systolic waveform analysis with generalized transfer functions), which employ a variety of signal processing steps to estimate central BP from peripheral signals.17,18 Yet, with no standardized guidelines,17 the accuracy testing of these new devices (as well as the preceding devices) has not been undertaken in a uniform fashion with comparable protocols, emphasizing the need for guidance in this field.19–22 An international task force was convened to address this situation
    corecore