13 research outputs found

    Rayonnement acoustique de structures de type ossature bois : comparaison entre méthode éléments finis et formulation intégrale

    Get PDF
    Un des points délicats de la construction bois se situe au niveau de l'isolation acoustique des planchers bois. L'objectif de cette article est de déterminer le rayonnement acoustique de ce type de structures (légÚres et nervurées). Deux méthodes sont présentés, l'une modélisant, par éléments finis, le domaine global (structure in-vivo) et son couplage, l'autre exploitant une méthode combinée (élément finis et formulation intégrale) sur la structure in-vacuo. Un code éléments finis sous licence libre (FreeFem++) est employé dans cette étude en comparaison avec un des codes commerciaux

    Wavelets operational methods for fractional differential equations and systems of fractional differential equations

    Get PDF
    In this thesis, new and effective operational methods based on polynomials and wavelets for the solutions of FDEs and systems of FDEs are developed. In particular we study one of the important polynomial that belongs to the Appell family of polynomials, namely, Genocchi polynomial. This polynomial has certain great advantages based on which an effective and simple operational matrix of derivative was first derived and applied together with collocation method to solve some singular second order differential equations of Emden-Fowler type, a class of generalized Pantograph equations and Delay differential systems. A new operational matrix of fractional order derivative and integration based on this polynomial was also developed and used together with collocation method to solve FDEs, systems of FDEs and fractional order delay differential equations. Error bound for some of the considered problems is also shown and proved. Further, a wavelet bases based on Genocchi polynomials is also constructed, its operational matrix of fractional order derivative is derived and used for the solutions of FDEs and systems of FDEs. A novel approach for obtaining operational matrices of fractional derivative based on Legendre and Chebyshev wavelets is developed, where, the wavelets are first transformed into corresponding shifted polynomials and the transformation matrices are formed and used together with the polynomials operational matrices of fractional derivatives to obtain the wavelets operational matrix. These new operational matrices are used together with spectral Tau and collocation methods to solve FDEs and systems of FDEs

    Assessment of Sewage Molecular Markers in Port Dickson Coast and Kim Kim River with Sediment Linear Alkylbenzenes

    Get PDF
    The present study aimed to determine linear alkylbenzenes (LABs) concentrations as organic molecular marker for sewage pollution in the sediment samples collected from Coast of Port Dickson and Kim Kim River, Peninsular Malaysia. The adverse effects of anthropogenic inputs into the rivers and coastal environment could be detected by molecular organic markers such as LABs. The sediments were processed; their sources were identified and tested by gas chromatography-mass spectrometry (GC-MS). The significance of the differences among sampling stations for LAB concentrations and distribution at p < 0.05 was performed by analysis of variance and Post Hoc Tests, LSD procedures (ANOVA) and Pearson correlation coefficient. LABs indices which include internal to external (I/E) congeners, long to short chains L/S and homologs C13/C12 were used to identify the sewage treatment and degradation levels. Results of this study are statistically uncovered that the range of RLABs concentration in the investigated locations was between 112.0; 88.3 and 256.0; 119.0 ngïżœg1 dw, respectively. There was significant difference (p < 0.05) of LAB homologs with high percentage of C13-LAB homologs along sampling locations. The calculated LAB ratios (I/E) were within the range between 2.0; 1.7 and 4.1, 2.0, demonstrated that, the treated effluents from primary and secondary sources were discharged to the study areas. The degradation of LABs was 40–64% and 34–38% in the studied locations. The findings of this study suggested the powerfully indicators of LABs in tracing anthropogenic sewage contamination and the necessity of continuing wastewater treatment system improvemen

    Impact of opioid-free analgesia on pain severity and patient satisfaction after discharge from surgery: multispecialty, prospective cohort study in 25 countries

    Get PDF
    Background: Balancing opioid stewardship and the need for adequate analgesia following discharge after surgery is challenging. This study aimed to compare the outcomes for patients discharged with opioid versus opioid-free analgesia after common surgical procedures.Methods: This international, multicentre, prospective cohort study collected data from patients undergoing common acute and elective general surgical, urological, gynaecological, and orthopaedic procedures. The primary outcomes were patient-reported time in severe pain measured on a numerical analogue scale from 0 to 100% and patient-reported satisfaction with pain relief during the first week following discharge. Data were collected by in-hospital chart review and patient telephone interview 1 week after discharge.Results: The study recruited 4273 patients from 144 centres in 25 countries; 1311 patients (30.7%) were prescribed opioid analgesia at discharge. Patients reported being in severe pain for 10 (i.q.r. 1-30)% of the first week after discharge and rated satisfaction with analgesia as 90 (i.q.r. 80-100) of 100. After adjustment for confounders, opioid analgesia on discharge was independently associated with increased pain severity (risk ratio 1.52, 95% c.i. 1.31 to 1.76; P &lt; 0.001) and re-presentation to healthcare providers owing to side-effects of medication (OR 2.38, 95% c.i. 1.36 to 4.17; P = 0.004), but not with satisfaction with analgesia (beta coefficient 0.92, 95% c.i. -1.52 to 3.36; P = 0.468) compared with opioid-free analgesia. Although opioid prescribing varied greatly between high-income and low- and middle-income countries, patient-reported outcomes did not.Conclusion: Opioid analgesia prescription on surgical discharge is associated with a higher risk of re-presentation owing to side-effects of medication and increased patient-reported pain, but not with changes in patient-reported satisfaction. Opioid-free discharge analgesia should be adopted routinely

    SU-8 waveguiding interferometric micro-sensor for gage pressure measurement

    No full text
    International audienceThe authors present a successful modeling, realization and characterization of a new micro-sensor based on a convenient optical principle, namely an integrated Mach–Zehnder interferometer (MZI). This MZI device is designed with a view to measuring pressure disturbances due to optical path variations. Such a system is arranged in order to work in intensity modulation scheme. Moreover, the MZI is made up of straight and bent rib optical waveguides composed of SU-8 polymer. The mainstay of the device is based on differential measurements performed by a sensing arm arranged with a micromachined membrane and actuated by a given pressure disturbance, while the second arm of the interferometer is considered as a reference one. The main parameters of each element are given by way of two modeling approaches: an optical modeling with a semi-vectorial finite difference method together with a conformal transformation, and a mechanical modeling with a finite-element method associated to the mechanical theory of membranes. So, as the pressure to be measured is applied upon the diaphragm, an optical path variation of the acting arm is induced. After the combination of both signals, the variation at the output of the system is measured. A prototype is characterized by way of a micro-optical injection bench specifically designed to allow an efficient end-fire coupling into the waveguides

    Integrated Mach-Zehnder interferometer on SU-8 polymer for designing pressure sensors

    No full text
    International audienceThis paper describes a new integrated pressure sensor based on a Mach-Zehnder (MZ) interferometer made of SU-8 polymer. Such a device is designed with a view to working in a standard intensity modulation scheme. To this end, the device takes advantage of a differential measurement thanks to a sensing arm of the MZ structure arranged upon a thin membrane actuated by the pressure to be dealt with, while the second arm allows for a reference signal. The combination of both signals out of the optimized structure of the interferometer allows us to detect any change in the optical path as a result of the applied pressure. A prototype is characterized by way of a specific optical bench allowing an efficient end-fire coupling into the sensor. Practical results prove such a design to delineate a promising measurement approac
    corecore