111 research outputs found

    Relationship between chemical composition and nematicidal activity of different essential oils

    Get PDF
    In this study, the relationship between nematicidal activity and chemical composition of ten essential oils (EOs) from different plant species was investigated both in in vitro assays on juveniles (J2) and eggs of the root-knot nematode Meloidogyne incognita and in experiments on tomato in soil infested by M. incognita. Nematode J2 were exposed for 4, 8 or 24 h to 0.78–100 ”g mL−1 concentrations of each EO, whereas 24, 48 or 96 h exposures to 250, 500 and 1000 ”g mL−1 solutions were tested on M. incognita egg masses. Treatments with 50, 100 or 200 ”g kg soil rates of each EO were applied in the experiment on potted tomato. The highest nematicidal potential resulted for the C. verum EO, as highly toxic to both M. incognita J2 and eggs and strongly suppressive on nematode multiplication on tomato roots. The infestation of M. incognita on tomato roots was also strongly reduced by the EOs from E. citriodora and S. aromaticum, both highly toxic to M. incognita J2 but less active on nematode eggs. Adversely, R. graveolens EO strongly inhibited the egg hatch but was limitedly toxic to the infective J2. Chemical composition of the EOs was determined by GC-FID and GC-MS. The ten EOs showed a very different chemical composition in terms of major phytochemicals, with one or two dominant components totally amounting up to 85%. The structure–activity relationship based on the main phytochemicals identified in the assayed EOs and their nematicidal effects on M. incognita was also discussed. Results from this study confirmed that the selection of suitable EO raw materials can lead to the formulation on new effective nematicidal products

    The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors

    Get PDF
    The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest bolometric mass ever operated. The experiment will work at a temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free system based on pulse tubes and a custom high power dilution refrigerator, designed to match these specifications. The cryostat has been commissioned in 2014 at the Gran Sasso National Laboratories and reached a record temperature of 6 mK on a cubic meter scale. In this paper, we present results of CUORE commissioning runs. Details on the thermal characteristics and cryogenic performances of the system will be also given.Comment: 7 pages, 2 figures, LTD16 conference proceedin

    A Low Nuclear Recoil Energy Threshold for Dark Matter Search with CRESST-III Detectors

    Get PDF
    The CRESST-III experiment (Cryogenic Rare Events Search with Superconducting Thermometers), located at the underground facility Laboratori Nazionali del Gran Sasso in Italy, uses scintillating CaWO₄ crystals as cryogenic calorimeters to search for direct dark matter interactions in detectors. A large part of the parameter space for spin-independent scattering off nuclei remains untested for dark matter particles with masses below a few GeV/cÂČ, despite many naturally motivated theoretical models for light dark matter particles. The CRESST-III detectors are designed to achieve the performance required to probe the low-mass region of the parameter space with a sensitivity never reached before. In this paper, new results on the performance and an overview of the CRESST-III detectors will be presented, emphasizing the results about the low-energy threshold for nuclear recoil of CRESST-III Phase 1 which started collecting data in August 2016. Keywords: Cryogenic detectors; Dark matter; Rare-event searche

    Searches for Light Dark Matter with the CRESST-III Experiment

    Get PDF
    Cryogenic Rare Event Search with Superconducting Thermometers (CRESST) is a long-standing direct dark matter detection experiment with cryogenic detectors located at the underground facility Laboratori Nazionali del Gran Sasso in Italy. CRESST-III, the third generation of CRESST, was specifically designed to have a world-leading sensitivity for low-mass dark matter (DM) (less than 2\ua0GeV/c 2) to probe the spin-independent DM-nucleus cross section. At present, a large part of the parameter space for spin-independent scattering off nuclei remains untested for dark matter particles with masses below few GeV/c 2 although many motivated theoretical models having been proposed. The CRESST-III experiment employs scintillating CaWO 4 crystals of ∌ 25\ua0g as target material for dark matter interactions operated as cryogenic scintillating calorimeters at\ua0∌ 10\ua0mK. CRESST-III first data taking was successfully completed in 2018, achieving an unprecedented energy threshold for nuclear recoils. This result extended the present sensitivity to DM particles as light as ∌ 160\ua0MeV/c 2. In this paper, an overview of the CRESST-III detectors and results will be presented

    Cryogenic characterization of a LiAlO 2 crystal and new results on spin-dependent dark matter interactions with ordinary matter: CRESST Collaboration

    Get PDF
    In this work, a first cryogenic characterization of a scintillating LiAlO 2 single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut fĂŒr KristallzĂŒchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO 2 at cryogenic temperatures. The second achieved an energy threshold of (213.02 ± 1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350MeV/c2 and 1.50GeV/c2. Secondly, a detector module with a 373 g LiAlO 2 crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments. © 2020, The Author(s)

    Lithium-Containing Crystals for Light Dark Matter Search Experiments

    Get PDF
    In the current direct dark matter search landscape, the leading experiments in the sub-GeV mass region mostly rely on cryogenic techniques which employ crystalline targets. One attractive type of crystals for these experiments is those containing lithium, due to the fact that 7Li is an ideal candidate to study spin-dependent dark matter interactions in the low mass region. Furthermore, 6Li can absorb neutrons, a challenging background for dark matter experiments, through a distinctive signature which allows the monitoring of the neutron flux directly on site. In this work, we show the results obtained with three different detectors based on LiAlO 2, a target crystal never used before in cryogenic experiments

    The CUORE and CUORE-0 experiments at LNGS

    Get PDF
    The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. The construction of the experiment and, in particular, the installation of all towers in the cryostat was completed in August 2016 and commissioning started in fall 2016. The experiment has completed the pre-operation phase and is currently in data taking. We present here the achievements of CUORE during the commissioning phase and the limit on the 130Te half-life for the neutrinoless double beta decay that has been released after the first 3 weeks of collected data. Physics results from CUORE-0 will also be updated

    Low energy analysis techniques for CUORE

    Get PDF
    CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils inCUORE-0

    Probing spin-dependent dark matter interactions with 6 Li: CRESST Collaboration

    Get PDF
    CRESST is one of the most prominent direct detection experiments for dark matter particles with sub- GeV/c2 mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of 6Li. This is now possible thanks to new calculations on nuclear matrix elements of this specific isotope of Li. To show the potential of using this particular nuclide for probing dark matter interactions, we used the data collected previously by a CRESST prototype based on LiAlO2 and operated in an above ground test-facility at Max-Planck-Institut fĂŒr Physik in Munich, Germany. In particular, the inclusion of 6Li in the limit calculation drastically improves the result obtained for spin-dependent interactions with neutrons in the whole mass range. The improvement is significant, greater than two order of magnitude for dark matter masses below 1 GeV/c2, compared to the limit previously published with the same data
    • 

    corecore