1,642 research outputs found

    Like trainer, like bot? Inheritance of bias in algorithmic content moderation

    Get PDF
    The internet has become a central medium through which `networked publics' express their opinions and engage in debate. Offensive comments and personal attacks can inhibit participation in these spaces. Automated content moderation aims to overcome this problem using machine learning classifiers trained on large corpora of texts manually annotated for offence. While such systems could help encourage more civil debate, they must navigate inherently normatively contestable boundaries, and are subject to the idiosyncratic norms of the human raters who provide the training data. An important objective for platforms implementing such measures might be to ensure that they are not unduly biased towards or against particular norms of offence. This paper provides some exploratory methods by which the normative biases of algorithmic content moderation systems can be measured, by way of a case study using an existing dataset of comments labelled for offence. We train classifiers on comments labelled by different demographic subsets (men and women) to understand how differences in conceptions of offence between these groups might affect the performance of the resulting models on various test sets. We conclude by discussing some of the ethical choices facing the implementers of algorithmic moderation systems, given various desired levels of diversity of viewpoints amongst discussion participants.Comment: 12 pages, 3 figures, 9th International Conference on Social Informatics (SocInfo 2017), Oxford, UK, 13--15 September 2017 (forthcoming in Springer Lecture Notes in Computer Science

    Electronic transport in polycrystalline graphene

    Full text link
    Most materials in available macroscopic quantities are polycrystalline. Graphene, a recently discovered two-dimensional form of carbon with strong potential for replacing silicon in future electronics, is no exception. There is growing evidence of the polycrystalline nature of graphene samples obtained using various techniques. Grain boundaries, intrinsic topological defects of polycrystalline materials, are expected to dramatically alter the electronic transport in graphene. Here, we develop a theory of charge carrier transmission through grain boundaries composed of a periodic array of dislocations in graphene based on the momentum conservation principle. Depending on the grain boundary structure we find two distinct transport behaviours - either high transparency, or perfect reflection of charge carriers over remarkably large energy ranges. First-principles quantum transport calculations are used to verify and further investigate this striking behaviour. Our study sheds light on the transport properties of large-area graphene samples. Furthermore, purposeful engineering of periodic grain boundaries with tunable transport gaps would allow for controlling charge currents without the need of introducing bulk band gaps in otherwise semimetallic graphene. The proposed approach can be regarded as a means towards building practical graphene electronics.Comment: accepted in Nature Material

    The impact of frozen sections on final surgical margins in squamous cell carcinoma of the oral cavity and lips: a retrospective analysis over an 11 years period

    Get PDF
    Taking intraoperative frozen sections (FS) is a widely used procedure in oncologic surgery. However so far no evidence of an association of FS analysis and premalignant changes in the surgical margin exists. Therefore, the aim of this study was to evaluate the impact of FS on different categories of the final margins of squamous cell carcinoma (SCC) of the oral cavity and lips

    Prolonged post-faint hypotension can be reversed by dynamic tension

    Get PDF
    A severe variant of vasovagal syncope, observed during tilt tests and blood donation has recently been termed “prolonged post-faint hypotension” (PPFH). A 49-year-old male with a life-long history of severe fainting attacks underwent head-up tilt for 20 min, and developed syncope 2 min after nitroglycerine spray. He was unconscious for 40 s and asystolic for 22 s. For the first 2 min of recovery, BP and HR remained low (65/45 mmHg and 40 beats/min) despite passive leg-raising. Blood pressure (and symptoms) only improved following active bilateral leg flexion and extension (“dynamic tension”). During PPFH, when vagal activity is extreme, patients may require central stimulation as well as correction of venous return

    Methods for specifying the target difference in a randomised controlled trial : the Difference ELicitation in TriAls (DELTA) systematic review

    Get PDF
    Peer reviewedPublisher PD

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data

    Global impression of perceived difficulties in children and adolescents with attention-deficit/hyperactivity disorder: Reliability and validity of a new instrument assessing perceived difficulties from a patient, parent and physician perspective over the day

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The objective of this analysis was to evaluate the psychometric properties of a brief scale developed to assess the degree of difficulties in children with Attention-Deficit/Hyperactivity Disorder (ADHD). The Global Impression of Perceived Difficulties (GIPD) scale reflects overall impairment, psychosocial functioning and Quality of Life (QoL) as rated by patient, parents and physician at various times of the day.</p> <p>Methods</p> <p>In two open-label studies, ADHD-patients aged 6–17 years were treated with atomoxetine (target-dose 0.5–1.2 mg/kg/day). ADHD-related difficulties were assessed up to week 24 using the GIPD. Data from both studies were combined to validate the scale.</p> <p>Results</p> <p>Overall, 421 patients received atomoxetine. GIPD scores improved over time. All three GIPD-versions (patient, parent, physician) were internally consistent; all items showed at least moderate item-total correlation. The scale showed good test-retest reliability over a two-week period from all three perspectives. Good convergent and discriminant validity was shown.</p> <p>Conclusion</p> <p>GIPD is an internally consistent, reliable and valid measure to assess difficulties in children with ADHD at various times of the day and can be used as indicator for psychosocial impairment and QoL. The scale is sensitive to treatment-related change.</p

    The Pioneer Anomaly

    Get PDF
    Radio-metric Doppler tracking data received from the Pioneer 10 and 11 spacecraft from heliocentric distances of 20-70 AU has consistently indicated the presence of a small, anomalous, blue-shifted frequency drift uniformly changing with a rate of ~6 x 10^{-9} Hz/s. Ultimately, the drift was interpreted as a constant sunward deceleration of each particular spacecraft at the level of a_P = (8.74 +/- 1.33) x 10^{-10} m/s^2. This apparent violation of the Newton's gravitational inverse-square law has become known as the Pioneer anomaly; the nature of this anomaly remains unexplained. In this review, we summarize the current knowledge of the physical properties of the anomaly and the conditions that led to its detection and characterization. We review various mechanisms proposed to explain the anomaly and discuss the current state of efforts to determine its nature. A comprehensive new investigation of the anomalous behavior of the two Pioneers has begun recently. The new efforts rely on the much-extended set of radio-metric Doppler data for both spacecraft in conjunction with the newly available complete record of their telemetry files and a large archive of original project documentation. As the new study is yet to report its findings, this review provides the necessary background for the new results to appear in the near future. In particular, we provide a significant amount of information on the design, operations and behavior of the two Pioneers during their entire missions, including descriptions of various data formats and techniques used for their navigation and radio-science data analysis. As most of this information was recovered relatively recently, it was not used in the previous studies of the Pioneer anomaly, but it is critical for the new investigation.Comment: 165 pages, 40 figures, 16 tables; accepted for publication in Living Reviews in Relativit

    An Improved Test for Detecting Multiplicative Homeostatic Synaptic Scaling

    Get PDF
    Homeostatic scaling of synaptic strengths is essential for maintenance of network “gain”, but also poses a risk of losing the distinctions among relative synaptic weights, which are possibly cellular correlates of memory storage. Multiplicative scaling of all synapses has been proposed as a mechanism that would preserve the relative weights among them, because they would all be proportionately adjusted. It is crucial for this hypothesis that all synapses be affected identically, but whether or not this actually occurs is difficult to determine directly. Mathematical tests for multiplicative synaptic scaling are presently carried out on distributions of miniature synaptic current amplitudes, but the accuracy of the test procedure has not been fully validated. We now show that the existence of an amplitude threshold for empirical detection of miniature synaptic currents limits the use of the most common method for detecting multiplicative changes. Our new method circumvents the problem by discarding the potentially distorting subthreshold values after computational scaling. This new method should be useful in assessing the underlying neurophysiological nature of a homeostatic synaptic scaling transformation, and therefore in evaluating its functional significance

    Survival bias and drug interaction can attenuate cross-sectional case-control comparisons of genes with health outcomes. An example of the kinesin-like protein 6 (KIF6) Trp719Arg polymorphism and coronary heart disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Case-control studies typically exclude fatal endpoints from the case set, which we hypothesize will substantially underestimate risk if survival is genotype-dependent. The loss of fatal cases is particularly nontrivial for studies of coronary heart disease (CHD) because of significantly reduced survival (34% one-year fatality following a coronary attack). A case in point is the <it>KIF6 </it>Trp719Arg polymorphism (rs20455). Whereas six prospective studies have shown that carriers of the <it>KIF6 </it>Trp719Arg risk allele have 20% to 50% greater CHD risk than non-carriers, several cross-sectional case-control studies failed to show that carrier status is related to CHD. Computer simulations were therefore employed to assess the impact of the loss of fatal events on gene associations in cross-sectional case-control studies, using <it>KIF6 </it>Trp719Arg as an example.</p> <p>Results</p> <p>Ten replicates of 1,000,000 observations each were generated reflecting Canadian demographics. Cardiovascular disease (CVD) risks were assigned by the Framingham equation and events distributed among <it>KIF6 </it>Trp719Arg genotypes according to published prospective studies. Logistic regression analysis was used to estimate odds ratios between <it>KIF6 </it>genotypes. Results were examined for 33%, 41.5%, and 50% fatality rates for incident CVD.</p> <p>In the absence of any difference in percent fatalities between genotypes, the odds ratios (carriers vs. noncarriers) were unaffected by survival bias, otherwise the odds ratios were increasingly attenuated as the disparity between fatality rates increased between genotypes. Additional simulations demonstrated that statin usage, shown in four clinical trials to substantially reduce the excess CHD risk in the <it>KIF6 </it>719Arg variant, should also attenuate the <it>KIF6 </it>719Arg odds ratio in case-control studies.</p> <p>Conclusions</p> <p>These computer simulations show that exclusions of prior CHD fatalities attenuate odds ratios of case-control studies in proportion to the difference in the percent fatalities between genotypes. Disproportionate CHD survival for <it>KIF6 </it>Trip719Arg carriers is suggested by their 50% greater risk for recurrent myocardial infarction. This, and the attenuation of <it>KIF6 </it>719Arg carrier risk with statin use, may explain the genotype's weak association with CHD in cross-sectional case-control studies. The results may be relevant to the underestimation of risk in cross-sectional case-control studies of other genetic CHD-risk factors affecting survival.</p
    corecore