13 research outputs found

    Prevalence of subclinical ketosis and relationships with postpartum diseases in European dairy cows

    Get PDF
    Subclinical ketosis (SCK) is defined as concentrations of β-hydroxybutyrate (BHBA) ≥ 1.2 to 1.4 mmol/L and it is considered a gateway condition for other metabolic and infectious disorders such as metritis, mastitis, clinical ketosis, and displaced abomasum. Reported prevalence rates range from 6.9 to 43% in the first 2 mo of lactation. However, there is a dearth of information on prevalence rates considering the diversity of European dairy farms. The objectives of this study were to (1) determine prevalence of SCK, (2) identify thresholds of BHBA, and (3) study their relationships with postpartum metritis, clinical ketosis, displaced abomasum, lameness, and mastitis in European dairy farms. From May to October 2011, a convenience sample of 528 dairy herds from Croatia, Germany, Hungary, Italy, Poland, Portugal, Serbia, Slovenia, Spain, and Turkey was studied. β-Hydroxybutyrate levels were measured in 5,884 cows with a handheld meter within 2 to 15 d in milk (DIM). On average, 11 cows were enrolled per farm and relevant information (e.g., DIM, postpartum diseases, herd size) was recorded. Using receiver operator characteristic curve analyses, blood BHBA thresholds were determined for the occurrence of metritis, mastitis, clinical ketosis, displaced abomasum, and lameness. Multivariate binary logistic regression models were built for each disease, considering cow as the experimental unit and herd as a random effect. Overall prevalence of SCK (i.e., blood BHBA ≥ 1.2 mmol/L) within 10 countries was 21.8%, ranging from 11.2 to 36.6%. Cows with SCK had 1.5, 9.5, and 5.0 times greater odds of developing metritis, clinical ketosis, and displaced abomasum, respectively. Multivariate binary logistic regression models demonstrated that cows with blood BHBA levels of ≥ 1.4, ≥ 1.1 and ≥ 1.7 mmol/L during 2 to 15 DIM had 1.7, 10.5, and 6.9 times greater odds of developing metritis, clinical ketosis, and displaced abomasum, respectively, compared with cows with lower BHBA blood levels. Interestingly, a postpartum blood BHBA threshold ≥ 1.1 mmol/L increased the odds for lameness in dairy cows 1.8 (95% confidence interval: 1.3 to 2.5) times. Overall, prevalence of SCK was high between 2 to 15 DIM and SCK increased the odds of metritis, clinical ketosis, lameness, and displaced abomasum in European dairy herds

    SARS-CoV-2 RBD trimer protein adjuvanted with Alum-3M-052 protects from SARS-CoV-2 infection and immune pathology in the lung

    Get PDF
    There is a great need for the development of vaccines that induce potent and long-lasting protective immunity against SARS-CoV-2. Multimeric display of the antigen combined with potent adjuvant can enhance the potency and longevity of the antibody response. The receptor binding domain (RBD) of the spike protein is a primary target of neutralizing antibodies. Here, we developed a trimeric form of the RBD and show that it induces a potent neutralizing antibody response against live virus with diverse effector functions and provides protection against SARS-CoV-2 challenge in mice and rhesus macaques. The trimeric form induces higher neutralizing antibody titer compared to monomer with as low as 1ÎĽg antigen dose. In mice, adjuvanting the protein with a TLR7/8 agonist formulation alum-3M-052 induces 100-fold higher neutralizing antibody titer and superior protection from infection compared to alum. SARS-CoV-2 infection causes significant loss of innate cells and pathology in the lung, and vaccination protects from changes in innate cells and lung pathology. These results demonstrate RBD trimer protein as a suitable candidate for vaccine against SARS-CoV-2

    Influence of Ovarian Side and Initiation Time of First Aspiration with Relation of Transvaginal Follicular Aspiration in HF x Sahiwal Cows

    No full text
    This study was carried out to observe the influence of ovarian side and initiation time of first aspiration during OPU programme in HF X Sahiwal cows. Eight cows were randomly divided in to two groups (A and B) each consisting of 4 donors. Follicular aspiration was initiated on day 4 (first follicular wave) and day 13 (second follicular wave) of estrous cycle, respectively. From group-A donors, total 200 follicles were aspirated in eight sessions with a mean of 6.25 ± 2.05 per animal per session of which 52.50 (105/200) and 47.50 (95/200) per cent follicles were from left and right ovary, respectively. The mean numbers of small, medium and large follicles aspirated were 2.06 ± 0.87, 2.65 ± 0.88 and 1.53 ± 0.91 with the recovery rate of 33.0 (66/200) (3–5 mm), 42.50 (85/200) (6–9 mm) and 24.50 (49/200) (=10 mm) per cent, respectively. From group-B donors, total 179 follicles were aspirated of which 48.60 (87/179) and 51.40 (92/179) per cent follicles were from left and right ovary, respectively. The mean number of aspirated follicles per cow per session from group-B donor cows was 5.59 ± 1.03 and the mean numbers of small, medium and large follicles aspirated 1.87 ± 0.96, 2.5 ± 0.66 and 1.25 ± 0.64 with the recovery rate of 34.07 (61/179), 44.94 (80/179) and 21.22 (38/179) per cent, respectively. The number of follicles from left and right ovaries of different categories among group A and B donor cows did not differ significantly (P>0.05). This study showed that there cows no any influence of ovarian side and initiation time on follicular aspiration. [Vet. World 2010; 3(6.000): 286-288

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics

    ILC Reference Design Report Volume 3 - Accelerator

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC
    corecore