1,120 research outputs found

    Impedance of a sphere oscillating in an elastic medium with and without slip

    Get PDF
    The dynamic impedance of a sphere oscillating in an elastic medium is considered. Oestreicher's formula for the impedance of a sphere bonded to the surrounding medium can be expressed simply in terms of three lumped impedances associated with the displaced mass and the longitudinal and transverse waves. If the surface of the sphere slips while the normal velocity remains continuous, the impedance formula is modified by adjusting the definition of the transverse impedance to include the interfacial impedance.Comment: 10 pages, 2 figure

    Validation of the AX3 triaxial accelerometer in older functionally impaired people

    Get PDF
    Background: Studying physical activity (PA) trends in older populations and potential interventions for increasing PA is important, as PA is a factor in many age-related health outcomes such as chronic disease, premature mortality, physical function, and injuries from falls[1]. Objective measures of PA provide valuable information regarding the functional impact that ageing and chronic disease states may have on a patient’s life. Aims: The purpose of this study was to test the validity of the AX3 PA monitor in an older population, to investigate if the AX3 is a valid measure of distinct types or levels of activity in older people with a spectrum of mobility. Methods: Validity of the AX3 PA monitor was tested using the RT3 as a means of cross validating the AX3. Study participants wore both the AX3 and the RT3 accelerometers, positioned on their non-dominant side, while completing a series of standardised everyday activities. Results: Although overall correlation was high (r>0.8) between the RT3 and lower-limb mounted AX3 counts, the correlation between the two devices was much stronger for walking activity than for any of the non-walking activities. Discussion: Activity counts at all lower limb positions for the AX3 and RT3 were highly correlated. Correlation between wrist-mounted AX3 counts and lower limb AX3 counts was only moderate, and worsened when walking aids were in use. Conclusions: The results of this study indicate that the AX3 monitor is a valid tool, which might be used to objectively measure walking activity in older, functionally impaired adults; a welcome finding for this under-researched area

    Binocular Goggle Augmented Imaging and Navigation System provides real-time fluorescence image guidance for tumor resection and sentinel lymph node mapping

    Get PDF
    The inability to identify microscopic tumors and assess surgical margins in real-time during oncologic surgery leads to incomplete tumor removal, increases the chances of tumor recurrence, and necessitates costly repeat surgery. To overcome these challenges, we have developed a wearable goggle augmented imaging and navigation system (GAINS) that can provide accurate intraoperative visualization of tumors and sentinel lymph nodes in real-time without disrupting normal surgical workflow. GAINS projects both near-infrared fluorescence from tumors and the natural color images of tissue onto a head-mounted display without latency. Aided by tumor-targeted contrast agents, the system detected tumors in subcutaneous and metastatic mouse models with high accuracy (sensitivity = 100%, specificity = 98% ± 5% standard deviation). Human pilot studies in breast cancer and melanoma patients using a near-infrared dye show that the GAINS detected sentinel lymph nodes with 100% sensitivity. Clinical use of the GAINS to guide tumor resection and sentinel lymph node mapping promises to improve surgical outcomes, reduce rates of repeat surgery, and improve the accuracy of cancer staging

    Circular dichroism spectroscopic detection of ligand binding induced subdomain IB specific structural adjustment of human serum albumin

    Get PDF
    This work demonstrates for the first time that binding of various compounds within subdomain IB of human serum albumin (HSA) provokes characteristic changes in the near-UV circular dichroism (CD) spectrum of the protein. It can be inferred from the spectroscopic features of difference ellipticity signals and from CD displacement experiments that tyrosine residues located in subdomain IB are the source of the observed spectral alterations. It is proposed that inclusion of some ligand molecules (bile acids, dehydroepiandrosterone sulfate, steroidal terpenes, fatty acids, ibuprofen, and gemfibrozil) into the pocket of subdomain IB disrupts the Tyr138?Tyr161 interhelical π?π stacking interaction, which is reflected in the CD spectrum. This phenomenon can be utilized for the CD detection of subdomain IB specific binding of endo- as well as exogenous agents and to study the drug binding associated local conformational adaptation of the HSA molecule

    Survival after stroke in south London

    Get PDF

    Statistical power considerations in genotype-based recall randomized controlled trials

    Get PDF
    Randomized controlled trials (RCT) are often underpowered for validating gene-treatment interactions. Using published data from the Diabetes Prevention Program (DPP), we examined power in conventional and genotype-based recall (GBR) trials. We calculated sample size and statistical power for genemetformin interactions (vs. placebo) using incidence rates, gene-drug interaction effect estimates and allele frequencies reported in the DPP for the rs8065082 SLC47A1 variant, a metformin transported encoding locus. We then calculated statistical power for interactions between genetic risk scores (GRS), metformin treatment and intensive lifestyle intervention (ILI) given a range of sampling frames, clinical trial sample sizes, interaction effect estimates, and allele frequencies; outcomes were type 2 diabetes incidence (time-to-event) and change in small LDL particles (continuous outcome). Thereafter, we compared two recruitment frameworks: GBR (participants recruited from the extremes of a GRS distribution) and conventional sampling (participants recruited without explicit emphasis on genetic characteristics). We further examined the influence of outcome measurement error on statistical power. Under most simulated scenarios, GBR trials have substantially higher power to observe gene-drug and gene-lifestyle interactions than same-sized conventional RCTs. GBR trials are becoming popular for validation of gene-treatment interactions; our analyses illustrate the strengths and weaknesses of this design
    corecore