21 research outputs found

    Multitarget Stool DNA Test Performance in an Average-Risk Colorectal Cancer Screening Population

    Get PDF
    INTRODUCTION: We set out to evaluate the performance of a multitarget stool DNA (MT-sDNA) in an average-risk colonoscopy-controlled colorectal cancer (CRC) screening population. MT-sDNA stool test results were evaluated against fecal immunochemical test (FIT) results for the detection of different lesions, including molecularly defined high-risk adenomas and several other tumor characteristics. METHODS: Whole stool samples (n = 1,047) were prospectively collected and subjected to an MT-sDNA test, which tests for KRAS mutations, NDRG4 and BMP3 promoter methylation, and hemoglobin. Results for detecting CRC (n = 7), advanced precancerous lesions (advanced adenoma [AA] and advanced serrated polyps; n = 119), and non-AAs (n = 191) were compared with those of FIT alone (thresholds of 50, 75, and 100 hemoglobin/mL). AAs with high risk of progression were defined by the presence of specific DNA copy number events as measured by low-pass whole genome sequencing. RESULTS: The MT-sDNA test was more sensitive than FIT alone in detecting advanced precancerous lesions (46% (55/119) vs 27% (32/119), respectively, P < 0.001). Specificities among individuals with nonadvanced or negative findings (controls) were 89% (791/888) and 93% (828/888) for MT-sDNA and FIT testing, respectively. A positive MT-sDNA test was associated with multiple lesions (P = 0.005), larger lesions (P = 0.03), and lesions with tubulovillous architecture (P = 0.04). The sensitivity of the MT-sDNA test or FIT in detecting individuals with high-risk AAs (n = 19) from individuals with low-risk AAs (n = 52) was not significantly different. DISCUSSION: In an average-risk screening population, the MT-sDNA test has an increased sensitivity for detecting advanced precancerous lesions compared with FIT alone. AAs with a high risk of progression were not detected with significantly higher sensitivity by MT-sDNA or FIT

    2BIC: Taking your adventuring gear to organise pop-up health information literacy sessions.

    No full text
    Academic libraries play an important role in the provision of health information literacy (IL) skills and there are many approaches to how these can be delivered. In this paper, guest writers Inge Dis- cart and colleagues from KU Leuven Libraries 2Bergen Information Centre (2BIC) in Belgium discuss a pop-up information literacy skills project. In particular, the article presents the findings from an initial information skills needs assessment con- ducted at the University, followed by how the con- cept of the pop-up sessions was developed and promoted throughout the organisation. The paper identifies the variety of sessions offered and the format in which they were delivered, with final results on how these were received and which ses- sions were the most popular. This article provi des insight into an alternative approach to health information skills delivery and the outcomes from it.status: publishe

    Coronaviruses as Vectors: Position Dependence of Foreign Gene Expression

    No full text
    Coronaviruses are the enveloped, positive-stranded RNA viruses with the largest RNA genomes known. Several features make these viruses attractive as vaccine and therapeutic vectors: (i) deletion of their nonessential genes is strongly attenuating; (ii) the genetic space thus created allows insertion of foreign information; and (iii) their tropism can be modified by manipulation of the viral spike. We studied here their ability to serve as expression vectors by inserting two different foreign genes and evaluating systematically the genomic position dependence of their expression, using a murine coronavirus as a model. Renilla and firefly luciferase expression cassettes, each provided with viral transcription regulatory sequences (TRSs), were inserted at several genomic positions, both independently in different viruses and combined within one viral genome. Recombinant viruses were generated by using a convenient method based on targeted recombination and host cell switching. In all cases high expression levels of the foreign genes were observed without severe effects on viral replication in vitro. The expression of the inserted gene appeared to be dependent on its genomic position, as well as on the identity of the gene. Expression levels increased when the luciferase gene was inserted closer to the 3′ end of the genome. The foreign gene insertions generally reduced the expression of upstream viral genes. The results are consistent with coronavirus transcription models in which the transcription from upstream TRSs is attenuated by downstream TRSs. Altogether, our observations clearly demonstrate the potential of coronaviruses as (multivalent) expression vectors

    Comparative Study of Targeted and Label-free Mass Spectrometry Methods for Protein Quantification

    No full text
    We compared data acquired on an LTQ-Orbitrap MS used in a typical shotgun proteomics setting (optimized for protein identification) with data from a quadrupole ion trap MS operated in the MRM mode. Six relative abundant proteins were quantified in identical sets of serum and CSF samples by the following methods: a qual/quant method with and without use of internal standards and a quantitative method (MRM with use of internal standards). Comparison of these methods with an antibody-based method in CSF samples showed good linearity for both methods (<i>R</i><sup>2</sup> of 0.961 and 0.971 for the qual/quant method with use of internal standards and the quantitative method, respectively). Besides its better linearity, the quantitative method was also more reproducible with lower CVs for all samples. Next to these comparisons we also explored why a qual/quant approach had typically a lower reproducibility compared to MRM analyses. We observed that modified peptides, or peptides with a cysteine or a methionine, yielded a significant increase in CV. Furthermore, a positive correlation was found between the length of the peptide and the CV. We conclude that qual/quant is an alternative for the quantification of abundant proteins and that the use of internal standards in qual/quant could be advantageous. Furthermore, the ongoing development in MS techniques increases the possibilities of qual/quant in protein quantification

    Standardised training for endoscopic mucosal resection of large non-pedunculated colorectal polyps to reduce recurrence (*STAR-LNPCP study): a multicentre cluster randomised trial

    No full text
    Objective Endoscopic mucosal resection (EMR) is the preferred treatment for non-invasive large (≥20 mm) non-pedunculated colorectal polyps (LNPCPs) but is associated with an early recurrence rate of up to 30%. We evaluated whether standardised EMR training could reduce recurrence rates in Dutch community hospitals. Design In this multicentre cluster randomised trial, 59 endoscopists from 30 hospitals were randomly assigned to the intervention group (e-learning and 2-day training including hands-on session) or control group. From April 2019 to August 2021, all consecutive EMR-treated LNPCPs were included. Primary endpoint was recurrence rate after 6 months. Results A total of 1412 LNPCPs were included; 699 in the intervention group and 713 in the control group (median size 30 mm vs 30 mm, 45% vs 52% size, morphology, site and access (SMSA) score IV, 64% vs 64% proximal location). Recurrence rates were lower in the intervention group compared with controls (13% vs 25%, OR 0.43; 95% CI 0.23 to 0.78; p=0.005) with similar complication rates (8% vs 9%, OR 0.93; 95% CI 0.64 to 1.36; p=0.720). Recurrences were more often unifocal in the intervention group (92% vs 76%; p=0.006). In sensitivity analysis, the benefit of the intervention on recurrence rate was only observed in the 20-40 mm LNPCPs (5% vs 20% in 20-29 mm, p=0.001; 10% vs 21% in 30-39 mm, p=0.013) but less evident in ≥40 mm LNPCPs (24% vs 31%; p=0.151). In a post hoc analysis, the training effect was maintained in the study group, while in the control group the recurrence rate remained high. Conclusion A compact standardised EMR training for LNPCPs significantly reduced recurrences in community hospitals. This strongly argues for a national dedicated training programme for endoscopists performing EMR of ≥20 mm LNPCPs. Interestingly, in sensitivity analysis, this benefit was limited for LNPCPs ≥40 mm. Trial registration number NTR7477
    corecore