1,342 research outputs found
Towards a New Standard Model for Black Hole Accretion
We briefly review recent developments in black hole accretion disk theory,
emphasizing the vital role played by magnetohydrodynamic (MHD) stresses in
transporting angular momentum. The apparent universality of accretion-related
outflow phenomena is a strong indicator that large-scale MHD torques facilitate
vertical transport of angular momentum. This leads to an enhanced overall rate
of angular momentum transport and allows accretion of matter to proceed at an
interesting rate. Furthermore, we argue that when vertical transport is
important, the radial structure of the accretion disk is modified at small
radii and this affects the disk emission spectrum. We present a simple model
demonstrating how energetic, magnetically-driven outflows modify the emergent
disk emission spectrum with respect to that predicted by standard accretion
disk theory. A comparison of the predicted spectra against observations of
quasar spectral energy distributions suggests that mass accretion rates
inferred using the standard disk model may severely underestimate their true
values.Comment: To appear in the Fifth Stromlo Symposium Proceedings special issue of
ApS
Stationary shapes of deformable particles moving at low Reynolds numbers
Lecture Notes of the Summer School ``Microswimmers -- From Single Particle
Motion to Collective Behaviour'', organised by the DFG Priority Programme SPP
1726 (Forschungszentrum J{\"{u}}lich, 2015).Comment: Pages C7.1-16 of G. Gompper et al. (ed.), Microswimmers - From Single
Particle Motion to Collective Behaviour, Lecture Notes of the DFG SPP 1726
Summer School 2015, Forschungszentrum J\"ulich GmbH, Schriften des
Forschungszentrums J\"ulich, Reihe Key Technologies, Vol 110, ISBN
978-3-95806-083-
Error analysis of bulk density measurements for neutron moisture gauge calibration
Six bulk density sampling methods were evaluated for use in neutron gauge
calibration. All six methods provided estimates of bulk density which were
generally within 5% of bulk density profiles measured using a gamma probe.
Standard errors of estimate ranged from 3 to 7 %. When used with care,
downhole, coring, and drive samplers can be used to successfully measure soil
moisture and bulk density profiles for use in neutron probe calibration
B physics and extra dimensions
We compute the dominant new physics contributions to the processes Z -> b b and B - B in the context of two representative models with extra dimensions. The main thrust of the calculations focuses on how to control the effects of the infinite tower of Kaluza-Klein modes inside the relevant one-loop diagrams. By comparing the results with the existing experimental data, most importantly those for Rb, we show that one may derive interesting lower bounds on the size of the compactification scale Mc
Resistive and magnetized accretion flows with convection
We considered the effects of convection on the radiatively inefficient
accretion flows (RIAF) in the presence of resistivity and toroidal magnetic
field. We discussed the effects of convection on transports of angular momentum
and energy. We established two cases for the resistive and magnetized RIAFs
with convection: assuming the convection parameter as a free parameter and
using mixing-length theory to calculate convection parameter. A self-similar
method was used to solve the integrated equations that govern the behavior of
the presented model. The solutions showed that the accretion and rotational
velocities decrease by adding the convection parameter, while the sound speed
increases. Moreover, by using mixing-length theory to calculate convection
parameter, we found that the convection can be important in RIAFs with magnetic
field and resistivity.Comment: 7 pages, 3 figures, accepted by Ap&S
Soil bulk density sampling for neutron gauge calibration
The ASCE Task Committee on Neutron Gauge Calibration met in Logan, Utah in July
1992 to investigate the various methods of soil sampling, installation of access tubes,
effect of various parameters on gauge readings, methods of developing field calibration
curves and comparison of neutron gauge characteristics. Details of the overall objectives
of the study are covered by Stone (1993, this volume). This paper discusses the soil
sampling methods and presents a comparative result based on bulk density, time required
for sampling and cost of sampling equipment Other papers developed from this study
describe the soils, the three sites investigated and the problems related to the tube
installation process
The ASCE neutron probe calibration study: overview
A workshop was held at Logan, Utah to gather field information on
neutron probe calibration and operation. Several techniques and instruments
were compared. This paper serves to establish the background information for
the work and describe the overall approaches, conditions, and equipment. Other
papers presented at this conference provide detailed procedures and results
Neutron gauge calibration comparison of methods
Several methods for obtaining soil samples for determining soil water content were used
for field calibration of neutron gauges. This paper compares the results of calibration
curves obtained from the study data by comparing intercepts, slopes and correlation
coefficients ("r" values). The study found differences in characteristics between gauges
of the same brand, differences between brands and a great effect by access tube
materials on the calibration curve
Roughening Transition in a Moving Contact Line
The dynamics of the deformations of a moving contact line on a disordered
substrate is formulated, taking into account both local and hydrodynamic
dissipation mechanisms. It is shown that both the coating transition in contact
lines receding at relatively high velocities, and the pinning transition for
slowly moving contact lines, can be understood in a unified framework as
roughening transitions in the contact line. We propose a phase diagram for the
system in which the phase boundaries corresponding to the coating transition
and the pinning transition meet at a junction point, and suggest that for
sufficiently strong disorder a receding contact line will leave a
Landau--Levich film immediately after depinning. This effect may be relevant to
a recent experimental observation in a liquid Helium contact line on a Cesium
substrate [C. Guthmann, R. Gombrowicz, V. Repain, and E. Rolley, Phys. Rev.
Lett. {\bf 80}, 2865 (1998)].Comment: 16 pages, 6 encapsulated figure
Impact of left ventricular ejection fraction on clinical outcomes after left main coronary artery revascularization
Aim: To evaluate the impact of left ventricular ejection fraction (LVEF) on 3-year outcomes in patients with left main coronary artery disease (LMCAD) undergoing percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) in the EXCEL trial. Methods and results: The EXCEL trial randomized patients with LMCAD to PCI with everolimus-eluting stents (n = 948) or CABG (n = 957). Among 1804 patients with known baseline LVEF, 74 (4.1%) had LVEF <40% [heart failure with reduced ejection fraction (HFrEF)], 152 (8.4%) LVEF 40–49% [heart failure with mid-range ejection fraction (HFmrEF)] and 1578 (87.5%) LVEF ≥50% (heart failure with preserved ejection fraction). Patients with HFrEF vs. HFmrEF vs. preserved LVEF experienced a longer postoperative hospital stay (9.0 vs. 7.0 vs. 6.0 days, P = 0.02) with greater peri-procedural complications after CABG, while hospital stay after PCI was unaffected by LVEF (1.5 vs. 2.0 vs. 1.0 days, P = 0.20). The composite primary endpoint of death, stroke, or myocardial infarction at 3 years was 29.3% (PCI) vs. 27.6% (CABG) in patients with HFrEF, 16.2% vs. 15.0% in patients with HFmrEF, and 14.5% vs. 14.6% in those with preserved LVEF, respectively (Pinteraction = 0.90). Smoothing spline analysis demonstrated that the 3-year risk of all-cause death increased when LVEF decreased, both in patients undergoing CABG and PCI. Conclusion: In the EXCEL trial, the composite rate of death, stroke or myocardial infarction at 3 years was significantly higher in patients with HFrEF compared with HFmrEF or preserved LVEF, driven by an increased rate of all-cause death. No significant differences after PCI vs. CABG were observed among patients with HFrEF, HFmrEF and preserved LVEF. Longer-term follow-up could provide important insights on differences in clinical outcomes that might emerge over time. Clinical Trial Registration: ClinicalTrials.gov ID NCT01205776
- …