45 research outputs found

    Measurement of transverse spin effects in COMPASS on a polarised proton target

    Get PDF
    2007/2008After a short introduction to the physics of COMPASS and the description of the spectrometer, the RICH-1 upgrade project is presented within the performed laboratory activities. Also the preliminary results of the performances of the new RICH-1 are illustrated. The focus then moves on the analysis of the data, and taking advantage of the upgraded RICH-1, the Collins and the Sivers asymmetries, extracted from the data collected during the transverse run of 2007, are presented both for unidentified and identified hadrons.XXI Ciclo197

    Multichannel Time Synchronization Based on PTP through a High Voltage Isolation Buffer Network Interface for Thick-GEM Detectors

    Get PDF
    Data logging and complex algorithm implementations acting on multichannel systems with independent devices require the use of time synchronization. In the case of Gas Electron Multipliers (GEM) and Thick-GEM (THGEM) detectors, the biasing potential can be generated at the detector level via DC to DC converters operating at floating voltage. In this case, high voltage isolation buffers may be used to allow communication between the different channels. However, their use add non-negligible delays in the transmission channel, complicating the synchronization. Implementation of a simplified precise time protocol is presented for handling the synchronization on the Field Programmable Gate Array (FPGA) side of a Xilinx SoC Zynq ZC7Z030. The synchronization is done through a high voltage isolated bidirectional network interface built on a custom board attached to a commercial CIAA_ACC carrier. The results of the synchronization are shown through oscilloscope captures measuring the time drift over long periods of time, achieving synchronization in the order of nanoseconds

    Characterization of LAPPD timing at CERN PS testbeam

    Full text link
    Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm2^2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns risetime followed by a slightly longer falltime and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. The measured time resolution for single photoelectrons is about 80 ps r.m.s.Comment: 35 pages, 23 figure

    Multiplicities of charged pions and unidentified charged hadrons from deep-inelastic scattering of muons off an isoscalar target

    Get PDF
    Multiplicities of charged pions and unidentified hadrons produced in deep-inelastic scattering were measured in bins of the Bjorken scaling variable xx, the relative virtual-photon energy yy and the relative hadron energy zz. Data were obtained by the COMPASS Collaboration using a 160 GeV muon beam and an isoscalar target (6^6LiD). They cover the kinematic domain in the photon virtuality Q2Q^2 > 1(GeV/c)2)^2, 0.004<x<0.40.004 < x < 0.4, 0.2<z<0.850.2 < z < 0.85 and 0.1<y<0.70.1 < y < 0.7. In addition, a leading-order pQCD analysis was performed using the pion multiplicity results to extract quark fragmentation functions

    The Polarised Valence Quark Distribution from semi-inclusive DIS

    Get PDF
    The semi-inclusive difference asymmetry A^{h^{+}-h^{-}} for hadrons of opposite charge has been measured by the COMPASS experiment at CERN. The data were collected in the years 2002-2004 using a 160 GeV polarised muon beam scattered off a large polarised ^6LiD target and cover the range 0.006 < x < 0.7 and 1 < Q^2 < 100 (GeV/c)^2. In leading order QCD (LO) the asymmetry A_d^{h^{+}-h^{-}} measures the valence quark polarisation and provides an evaluation of the first moment of Delta u_v + Delta d_v which is found to be equal to 0.40 +- 0.07 (stat.) +- 0.05 (syst.) over the measured range of x at Q^2 = 10 (GeV/c)^2. When combined with the first moment of g_1^d previously measured on the same data, this result favours a non-symmetric polarisation of light quarks Delta u-bar = - Delta d-bar at a confidence level of two standard deviations, in contrast to the often assumed symmetric scenario Delta u-bar = Delta d-bar = Delta s-bar = Delta s.Comment: 7 pages, 3 figures, COMPASS, revised: details added, author list update

    Lifestyles and socio-cultural factors among children aged 6-8 years from five Italian towns: The MAPEC-LIFE study cohort

    Get PDF
    Background: Lifestyles profoundly determine the quality of an individual’s health and life since his childhood. Many diseases in adulthood are avoidable if health-risk behaviors are identified and improved at an early stage of life. The aim of the present research was to characterize a cohort of children aged 6–8 years selected in order to perform an epidemiological molecular study (the MAPEC_LIFE study), investigate lifestyles of the children that could have effect on their health status, and assess possible association between lifestyles and socio-cultural factors. Methods: A questionnaire composed of 148 questions was administered in two different seasons to parents of children attending 18 primary schools in five Italian cities (Torino, Brescia, Pisa, Perugia and Lecce) to obtain information regarding the criteria for exclusion from the study, demographic, anthropometric and health information on the children, as well as some aspects on their lifestyles and parental characteristics. The results were analyzed in order to assess the frequency of specific conditions among the different seasons and cities and the association between lifestyles and socio-economic factors. Results: The final cohort was composed of 1,164 children (50.9 boys, 95.4% born in Italy). Frequency of some factors appeared different in terms of the survey season (physical activity in the open air, the ways of cooking certain foods) and among the various cities (parents’ level of education and rate of employment, sport, traffic near the home, type of heating, exposure to passive smoking, ways of cooking certain foods). Exposure to passive smoking and cooking fumes, obesity, residence in areas with heavy traffic, frequency of outdoor play and consumption of barbecued and fried foods were higher among children living in families with low educational and/or occupational level while children doing sports and consuming toasted bread were more frequent in families with high socio-economic level. Conclusions: The socio-economic level seems to affect the lifestyles of children enrolled in the study including those that could cause health effects. Many factors are linked to the geographical area and may depend on environmental, cultural and social aspects of the city of residence

    Hybrid MPGD-based detectors of single photons for the upgrade of COMPASS RICH-1

    Get PDF
    A seven year-long R&D programme has been performed and the resulting detector architecture is a hybrid MPGD including two THick GEM (THGEM) multiplication stages followed a MICROMEGAS. The first THGEM board forms the photocathode support: its upper face is CsI coated. The properties of THGEM-based photocathodes have been studied in details. The two THGEM layers act as pre-amplification stages and, thanks to a staggered configuration, namely by the misalignment of the holes of the two THGEMs, the electron shower produced in the pre-amplification phase is distributed onto a larger surface portion of the following MICROMEGAS unit, where the final multiplication takes place: it is so possible to operate at gains as high as 105 and more even in radioactive environments. COMPASS RICH-1 is a large-size Cherenkov imaging counter with gaseous radiator for hadron identification up to 50 GeV/c. The construction of a set of large-size (unit size: 60 760 cm2) gaseous photon detectors based on the hybrid MPGD architecture for the upgrade of COMPASS RICH-1 is ongoing and the upgraded detector will be in operation in 2016. The R&D studies, the engineering aspects and the construction challenges are presented

    Multiplicities of charged kaons from deep-inelastic muon scattering off an isoscalar target

    Get PDF
    Precise measurements of charged-kaon multiplicities in deep inelastic scattering were performed. The results are presented in three-dimensional bins of the Bjorken scaling variable x, the relative virtual-photon energy y, and the fraction z of the virtual-photon energy carried by the produced hadron. The data were obtained by the COMPASS Collaboration by scattering 160 GeV muons off an isoscalar 6LiD target. They cover the kinematic domain View the MathML source in the photon virtuality, 0.0045 GeV/c2 in the invariant mass of the hadronic system. The results from the sum of the z -integrated K+ and K 12 multiplicities at high x point to a value of the non-strange quark fragmentation function larger than obtained by the earlier DSS fit

    Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised protons

    Get PDF
    Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise. © 2015
    corecore