26 research outputs found

    A Real-Time intelligent system for tracking patient condition

    Get PDF
    Hospitals have multiple data sources, such as embedded systems, monitors and sensors. The number of data available is increasing and the information are used not only to care the patient but also to assist the decision processes. The introduction of intelligent environments in health care institutions has been adopted due their ability to provide useful information for health professionals, either in helping to identify prognosis or also to understand patient condition. Behind of this concept arises this Intelligent System to track patient condition (e.g. critic events) in health care. This system has the great advantage of being adaptable to the environment and user needs. The system is focused in identifying critic events from data streaming (e.g. vital signs and ventilation) which is particularly valuable for understanding the patient’s condition. This work aims to demonstrate the process of creating an intelligent system capable of operating in a real environment using streaming data provided by ventilators and vital signs monitors. Its development is important to the physician because becomes possible crossing multiple variables in real-time by analyzing if a value is critic or not and if their variation has or not clinical importance

    Ambient-aware continuous care through semantic context dissemination

    Get PDF
    Background: The ultimate ambient-intelligent care room contains numerous sensors and devices to monitor the patient, sense and adjust the environment and support the staff. This sensor-based approach results in a large amount of data, which can be processed by current and future applications, e. g., task management and alerting systems. Today, nurses are responsible for coordinating all these applications and supplied information, which reduces the added value and slows down the adoption rate. The aim of the presented research is the design of a pervasive and scalable framework that is able to optimize continuous care processes by intelligently reasoning on the large amount of heterogeneous care data. Methods: The developed Ontology-based Care Platform (OCarePlatform) consists of modular components that perform a specific reasoning task. Consequently, they can easily be replicated and distributed. Complex reasoning is achieved by combining the results of different components. To ensure that the components only receive information, which is of interest to them at that time, they are able to dynamically generate and register filter rules with a Semantic Communication Bus (SCB). This SCB semantically filters all the heterogeneous care data according to the registered rules by using a continuous care ontology. The SCB can be distributed and a cache can be employed to ensure scalability. Results: A prototype implementation is presented consisting of a new-generation nurse call system supported by a localization and a home automation component. The amount of data that is filtered and the performance of the SCB are evaluated by testing the prototype in a living lab. The delay introduced by processing the filter rules is negligible when 10 or fewer rules are registered. Conclusions: The OCarePlatform allows disseminating relevant care data for the different applications and additionally supports composing complex applications from a set of smaller independent components. This way, the platform significantly reduces the amount of information that needs to be processed by the nurses. The delay resulting from processing the filter rules is linear in the amount of rules. Distributed deployment of the SCB and using a cache allows further improvement of these performance results

    Viral, bacterial, and fungal infections of the oral mucosa:Types, incidence, predisposing factors, diagnostic algorithms, and management

    Get PDF

    A multivariant secure framework for smart mobile health application

    Get PDF
    This is an accepted manuscript of an article published by Wiley in Transactions on Emerging Telecommunications Technologies, available online: https://doi.org/10.1002/ett.3684 The accepted version of the publication may differ from the final published version.Wireless sensor network enables remote connectivity of technological devices such as smart mobile with the internet. Due to its low cost as well as easy availability of data sharing and accessing devices, the Internet of Things (IoT) has grown exponentially during the past few years. The availability of these devices plays a remarkable role in the new era of mHealth. In mHealth, the sensors generate enormous amounts of data and the context-aware computing has proven to collect and manage the data. The context aware computing is a new domain to be aware of context of involved devices. The context-aware computing is playing a very significant part in the development of smart mobile health applications to monitor the health of patients more efficiently. Security is one of the key challenges in IoT-based mHealth application development. The wireless nature of IoT devices motivates attackers to attack on application; these vulnerable attacks can be denial of service attack, sinkhole attack, and select forwarding attack. These attacks lead intruders to disrupt the application's functionality, data packet drops to malicious end and changes the route of data and forwards the data packet to other location. There is a need to timely detect and prevent these threats in mobile health applications. Existing work includes many security frameworks to secure the mobile health applications but all have some drawbacks. This paper presents existing frameworks, the impact of threats on applications, on information, and different security levels. From this line of research, we propose a security framework with two algorithms, ie, (i) patient priority autonomous call and (ii) location distance based switch, for mobile health applications and make a comparative analysis of the proposed framework with the existing ones.Published onlin

    Ten golden rules for optimal antibiotic use in hospital settings: the WARNING call to action

    Get PDF
    Antibiotics are recognized widely for their benefits when used appropriately. However, they are often used inappropriately despite the importance of responsible use within good clinical practice. Effective antibiotic treatment is an essential component of universal healthcare, and it is a global responsibility to ensure appropriate use. Currently, pharmaceutical companies have little incentive to develop new antibiotics due to scientific, regulatory, and financial barriers, further emphasizing the importance of appropriate antibiotic use. To address this issue, the Global Alliance for Infections in Surgery established an international multidisciplinary task force of 295 experts from 115 countries with different backgrounds. The task force developed a position statement called WARNING (Worldwide Antimicrobial Resistance National/International Network Group) aimed at raising awareness of antimicrobial resistance and improving antibiotic prescribing practices worldwide. The statement outlined is 10 axioms, or “golden rules,” for the appropriate use of antibiotics that all healthcare workers should consistently adhere in clinical practice

    Low speed vertical axis current turbine (LS-VACT): Experimental results

    Get PDF
    Depleting of fossil fuels and climate change problem as well as the pollutions arise make the renewable energy one of the best options for long-term usage. In hydropower energy extraction, vertical axis marine current turbine applications; Savonius turbine, which has the ability to operate in low speed current is suitable with the Malaysia's sea conditions. However, due to the drawbacks which are low efficiency and low tip speed ratio, modifications need to be done to harness more power. Low Speed Vertical Axis Current Turbine is appeared to extract energy based on the Savonius rotor. In conjunction to this matter, laboratory work has been done in a way to study the relationship between Power Coefficient (Cp) and Tip Speed Ratio (λ), and also the relationship between Torque Coefficient (Ct) and Tip Speed Ratio (λ) at different current speed which are 0.32 m/s and 0.64 m/s

    Towards a Context Model for Human-Centered Design of Contextual Data Entry Systems in Healthcare Domain

    No full text
    11th International Conference on Engineering Psychology and Cognitive Ergonomics (EPCE 2014)International audienceData entry by physicians is a critical aspect in the health care domain, in which errors may lead to severe consequences for patients. This paper describes and discusses these aspects to support human-centered design of appropriate human-computer interaction technology. The following issues will be addressed, including system aim, users' profiles, interaction devices and environment of use, to cite the most important. Our work is based on a literature survey, questionnaires, and an active participatory design process conducted with healthcare professionals. Since the crucial factor is context of use, we elicited several relevant contextual attributes that enabled us to create and incrementally upgrade a context model. This conceptual model is intended to support a scenario-based design approach of future data entry systems. A few scenarios are provide
    corecore