    Early Periprosthetic Metastasis Following Total Hip Replacement in a Patient With Breast Carcinoma: A Case Report and Review of Literature

    Get PDF
    Early periprosthetic osteolysis following total hip replacement (THR) as a result of septic etiology has been well understood. Periprosthetic bone loss as a result of metastatic infiltration is an uncommon and infrequent cause of early, progressive loosening of joint replacement prosthesis. Proximal femur has been the most common site of involvement compared to acetabular prosthesis. The rarity of this clinical entity can lead to delay in definitive diagnosis and management, thus affecting the final outcome. Breast is the commonest site of carcinoma in female patients despite which not many cases of periprosthetic metastasis have been reported in the literature. We present the first case of extensive, isolated periacetabular bone destruction following a THR in a 59 years old female patient with a history of breast carcinoma. Patients with known primary malignancy should be screened thoroughly before operation and should be followed regularly after joint replacement surgery to detect any metastatic foci around the prosthesis

    Cemented Polyethylene Cups in Patients Younger Than 40 Years

    Get PDF
    Although uncemented cup implants frequently are used in young patients, we believe long-term survival rates of cups in these patients are somewhat disappointing, and therefore we have continued to use cemented cups in primary THA, even in young patients. However, in cases of acetabular bone stock defects, we also use bone impaction grafting. We prospectively followed 130 patients with 175 cemented cups; no patients were lost to followup. The mean age of the patients at surgery was 31 years (range, 16–39 years). An acetabular reconstruction with bone impaction grafting was performed in 84 hips (48%). The minimum followup was 2 years (average, 8.1 years; range, 2.0–18.5 years). Twenty-one of the 175 cups (12%) were revised at an average of 8.1 years (range, 2.0–18.5 years). Reasons for revision were infection (one early, seven late), recurrent dislocations (two), traumatic loosening (one), and aseptic loosening (10). The 10-year survival rate of all cemented cups with end point of revision for any cause was 85%. Survival with end point of aseptic loosening of all cups was 92%. Survival with end point of revision for aseptic loosening was 90% for the cups without impaction grafting and 95% for the cups with impaction grafting. We believe cemented acetabular cups in young patients have acceptable midterm survival; however, in the case of acetabular bone defects, we recommend reconstruction with impaction grafting

    Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement : a systematic review and meta-analysis

    Get PDF
    There are advocates of both two-dimensional (2D) and three-dimensional (3D) templating methods for planning total hip replacement. The aim of this study was to compare the accuracy of implant size prediction when using 2D and 3D templating methods for total hip arthroplasty, as well as to compare the inter- and intra-observer reliability in order to determine whether currently available methods are sufficiently reliable and reproducible. Medline, EMBASE and PubMed were searched to identify studies that compared the accuracy of 2D and 3D templating for total hip replacement. Results were screened using the PRISMA flowchart and included studies were assessed for their level of evidence using the Oxford CEBM criteria. Non-randomized trials were critically appraised using the MINORS tool, whilst randomized trials were assessed using the CASP RCT checklist. A series of meta-analyses of the data for accuracy were also conducted. Ten studies reported that 3D templating is an accurate and reliable method of templating for total hip replacement. Six studies compared 3D templating with 2D templating, all of which concluded that 3D templating was more accurate, with three finding a statistically significant difference. The meta-analyses showed that 3D CT templating is the most accurate method. This review supports the hypothesis that 3D templating is an accurate and reliable method of preoperative planning, which is more accurate than 2D templating for predicting implant size. However, further research is needed to ascertain the significance of this improved accuracy and whether it will yield any clinical benefit

    A rare case of arterial avulsion presenting with occult blood loss following total hip arthroplasty: a case report

    Get PDF
    INTRODUCTION: Iatrogenic arterial damage during total hip replacement is a rare but potentially life- or limb-threatening complication. To the best of our knowledge, this is the first reported case of an avulsion injury to a posterior branch of the profunda femoral artery during primary hip arthroplasty. CASE PRESENTATION: We describe the case of a 55-year-old Caucasian man who underwent a total hip replacement. The patient's hemoglobin levels dropped postoperatively, but there was no obvious bleeding, hemodynamic instability, pulsatile mass, or limb ischemia. The patient's hemoglobin levels continued to drop despite nine units of transfused blood. Three days after surgery, the patient underwent an angiography that showed an avulsion injury to a posterior branch of the profunda femoral artery. The avulsion was ligated and the hematoma was evacuated. CONCLUSION: Vascular damage may present in many ways including obvious bleeding, haemodynamic instability, a pulsatile mass, limb ischemia, and occult blood loss. Any of these signs in isolation or in combination could represent a vascular injury and an urgent angiogram should be considered

    The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review

    Get PDF
    BackgroundTo assess the Nickel sensitizing potential of total knee arthroplasty (TKA), explore the relationship between hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or postoperatively.Materials and methodsA literature search was performed through EMBASE, Medline and PubMed databases. Articles were screened independently by two investigators. The level of evidence of studies was assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the quality evaluated using the Methodological Index for Non-randomized Studies and Cochrane risk-of-bias tools.ResultsTwenty studies met the eligibility criteria, reporting on 1354 knee arthroplasties. Studies included patients undergoing primary or revision TKA, pre- and/or postoperatively, and used patch testing to identify Nickel hypersensitivity. Prevalence of Nickel hypersensitivity ranged from 0% to 87.5%. One study compared the prevalence of Nickel hypersensitivity in the same patient group before and after surgery and noted newly positive patch test reactions in three patients (4.2%). Three studies reported lower prevalence of Nickel hypersensitivity in postoperative patients compared to preoperative ones. Seven studies suggested that hypersensitivity might cause adverse clinical outcomes, but six did not support any relationship. Seven studies recommended preoperative patch testing in patients with history of metal allergy, and nine concluded that testing may be valuable postoperatively.ConclusionsPatients undergoing TKA with no prior history of metal hypersensitivity do not seem to be at an increased risk of developing Nickel hypersensitivity, and there is conflicting evidence that patients with pre-existing hypersensitivity are more likely to experience adverse outcomes. Patch testing remains the most commonly used method for diagnosing hypersensitivity, and evidence suggests preoperative testing in patients with history of metal allergy to aid prosthesis selection, and postoperatively in patients with suspected hypersensitivity once common causes of implant failure have been excluded, since revision with hypoallergenic implants may alleviate symptoms

    Validation of a 3D CT method for measurement of linear wear of acetabular cups: A hip simulator study

    Get PDF
    Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17?. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy

    Metal on metal hip resurfacing versus uncemented custom total hip replacement - early results

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>There is no current consensus on the most appropriate prosthesis for treating symptomatic osteoarthritis (OA) of the hip in young, active patients. Modern metal on metal hip resurfacing arthroplasty (HR) has gained popularity as it is theoretically more stable, bone conserving and easier to revise than total hip arthroplasty. Early results of metal on metal resurfacing have been encouraging. We have compared two well matched cohorts of patients with regard to function, pain relief and patient satisfaction.</p> <p>Methods</p> <p>This prospective study compares 2 cohorts of young, active patients treated with hip resurfacing (137 patients, 141 hips) and custom uncemented (CADCAM) stems (134 patients, 141 hips). All procedures were performed by a single surgeon. Outcome measures included Oxford, WOMAC and Harris hip scores as well as an activity score. Statistical analysis was performed using the unpaired student's t-test.</p> <p>Results</p> <p>One hundred and thirty four and 137 patients were included in the hip replacement and resurfacing groups respectively. The mean age of these patients was 54.6 years. The mean duration of follow up for the hip resurfacing group was 19.2 months compared to 13.4 months for the total hip replacement group.</p> <p>Pre operative oxford, Harris and WOMAC scores in the THA group were 41.1, 46.4 and 50.9 respectively while the post operative scores were 14.8, 95.8 and 5.0. In the HR group, pre- operative scores were 37.0, 54.1 and 45.9 respectively compared to 15.0, 96.8 and 6.1 post operatively. The degree of improvement was similar in both groups.</p> <p>Conclusion</p> <p>There was no significant clinical difference between the patients treated with hip resurfacing and total hip arthroplasty in the short term.</p