165 research outputs found

    Using Functional Near Infrared Spectroscopy (fNIRS) to study dynamic stereoscopic depth perception

    Get PDF
    The parietal cortex has been widely implicated in the processing of depth perception by many neuroimaging studies, yet functional near infrared spectroscopy (fNIRS) has been an under-utilised tool to examine the relationship of oxy- ([HbO]) and de-oxyhaemoglobin ([HbR]) in perception. Here we examine the haemodynamic response (HDR) to the processing of induced depth stimulation using dynamic random-dot-stereograms (RDS). We used fNIRS to measure the HDR associated with depth perception in healthy young adults (n = 13, mean age 24). Using a blocked design, absolute values of [HbO] and [HbR] were recorded across parieto-occipital and occipital cortices, in response to dynamic RDS. Control and test images were identical except for the horizontal shift in pixels in the RDS that resulted in binocular disparity and induced the percept of a 3D sine wave that 'popped out' of the test stimulus. The control stimulus had zero disparity and induced a 'flat' percept. All participants had stereoacuity within normal clinical limits and successfully perceived the depth in the dynamic RDS. Results showed a significant effect of this complex visual stimulation in the right parieto-occipital cortex (p < 0.01, η(2) = 0.54). The test stimulus elicited a significant increase in [HbO] during depth perception compared to the control image (p < 0.001, 99.99 % CI [0.008-0.294]). The similarity between the two stimuli may have resulted in the HDR of the occipital cortex showing no significant increase or decrease of cerebral oxygenation levels during depth stimulation. Cerebral oxygenation measures of [HbO] confirmed the strong association of the right parieto-occipital cortex with processing depth perception. Our study demonstrates the validity of fNIRS to investigate [HbO] and [HbR] during high-level visual processing of complex stimuli

    Screening for Meares-Irlen sensitivity in adults: can assessment methods predict changes in reading speed?

    Get PDF
    Two methods of assessing candidates for coloured overlays were compared with the aim of determining which method had the most practical utility. A total of 58 adults were assessed as potential candidates for coloured overlays, using two methods; a questionnaire, which identified self-reported previous symptoms, and a measure of perceptual distortions immediately prior to testing. Participants were classified as normal, Meares-Irlen sensitive, and borderline sensitive. Reading speed was measured with and without coloured overlays, using the Wilkins Rate of Reading Test and the change in speed was calculated. Participants classified as normal did not show any significant benefit from reading with an overlay. In contrast, a significant reading advantage was found for the borderline and Meares-Irlen participants. Current symptom rating was found to be a significant predictor of the change in reading speed, however the previous symptom rating was not found to be a reliable predictor. These data indicate that the assessment of perceptual distortions immediately prior to measuring colour preference and reading speed is the most meaningful method of assessing pattern glare and determining the utility of coloured overlays

    Personality dimensions of people who suffer from visual stress

    Get PDF
    Personality dimensions of participants who suffer from visual stress were compared with those of normal participants using the Eysenck Personality Inventory. Extraversion-Introversion scores showed no significant differences between the participants who suffered visual stress and those who were classified as normal. By contrast, significant differences were found between the normal participants and those with visual stress in respect of Neuroticism-Stability. These differences accord with Eysenck's personality theory which states that those who score highly on the neuroticism scale do so because they have a neurological system with a low threshold such that their neurological system is easily activated by external stimuli. The findings also relate directly to the theory of visual stress proposed by Wilkins which postulates that visual stress results from an excess of neural activity. The data may indicate that the excess activity is likely to be localised at particular neurological regions or neural processes

    Pattern selection in the absolutely unstable regime as a nonlinear eigenvalue problem: Taylor vortices in axial flow

    Full text link
    A unique pattern selection in the absolutely unstable regime of a driven, nonlinear, open-flow system is analyzed: The spatiotemporal structures of rotationally symmetric vortices that propagate downstream in the annulus of the rotating Taylor-Couette system due to an externally imposed axial through-flow are investigated for two different axial boundary conditions at the in- and outlet. Unlike the stationary patterns in systems without through-flow the spatiotemporal structures of propagating vortices are independent of parameter history, initial conditions, and system's length. They do, however, depend on the axial boundary conditions, the driving rate of the inner cylinder and the through-flow rate. Our analysis of the amplitude equation shows that the pattern selection can be described by a nonlinear eigenvalue problem with the frequency being the eigenvalue. Approaching the border between absolute and convective instability the eigenvalue problem becomes effectively linear and the selection mechanism approaches that one of linear front propagation. PACS:47.54.+r,47.20.Ky,47.32.-y,47.20.FtComment: 15 pages (LateX-file), 8 figures (Postscript

    Dynamical principles in neuroscience

    Full text link
    Dynamical modeling of neural systems and brain functions has a history of success over the last half century. This includes, for example, the explanation and prediction of some features of neural rhythmic behaviors. Many interesting dynamical models of learning and memory based on physiological experiments have been suggested over the last two decades. Dynamical models even of consciousness now exist. Usually these models and results are based on traditional approaches and paradigms of nonlinear dynamics including dynamical chaos. Neural systems are, however, an unusual subject for nonlinear dynamics for several reasons: (i) Even the simplest neural network, with only a few neurons and synaptic connections, has an enormous number of variables and control parameters. These make neural systems adaptive and flexible, and are critical to their biological function. (ii) In contrast to traditional physical systems described by well-known basic principles, first principles governing the dynamics of neural systems are unknown. (iii) Many different neural systems exhibit similar dynamics despite having different architectures and different levels of complexity. (iv) The network architecture and connection strengths are usually not known in detail and therefore the dynamical analysis must, in some sense, be probabilistic. (v) Since nervous systems are able to organize behavior based on sensory inputs, the dynamical modeling of these systems has to explain the transformation of temporal information into combinatorial or combinatorial-temporal codes, and vice versa, for memory and recognition. In this review these problems are discussed in the context of addressing the stimulating questions: What can neuroscience learn from nonlinear dynamics, and what can nonlinear dynamics learn from neuroscience?This work was supported by NSF Grant No. NSF/EIA-0130708, and Grant No. PHY 0414174; NIH Grant No. 1 R01 NS50945 and Grant No. NS40110; MEC BFI2003-07276, and Fundación BBVA

    Age-related changes in global motion coherence: conflicting haemodynamic and perceptual responses

    Get PDF
    Our aim was to use both behavioural and neuroimaging data to identify indicators of perceptual decline in motion processing. We employed a global motion coherence task and functional Near Infrared Spectroscopy (fNIRS). Healthy adults (n = 72, 18-85) were recruited into the following groups: young (n = 28, mean age = 28), middle-aged (n = 22, mean age = 50), and older adults (n = 23, mean age = 70). Participants were assessed on their motion coherence thresholds at 3 different speeds using a psychophysical design. As expected, we report age group differences in motion processing as demonstrated by higher motion coherence thresholds in older adults. Crucially, we add correlational data showing that global motion perception declines linearly as a function of age. The associated fNIRS recordings provide a clear physiological correlate of global motion perception. The crux of this study lies in the robust linear correlation between age and haemodynamic response for both measures of oxygenation. We hypothesise that there is an increase in neural recruitment, necessitating an increase in metabolic need and blood flow, which presents as a higher oxygenated haemoglobin response. We report age-related changes in motion perception with poorer behavioural performance (high motion coherence thresholds) associated with an increased haemodynamic response

    Rapid Intradermal Delivery of Liquid Formulations Using a Hollow Microstructured Array

    Get PDF
    Purpose The purpose of this work is to demonstrate rapid intradermal delivery of up to 1.5 mL of formulation using a hollow microneedle delivery device designed for self-application. Methods 3M’s hollow Microstructured Transdermal System (hMTS) was applied to domestic swine to demonstrate delivery of a variety of formulations including small molecule salts and proteins. Blood samples were collected after delivery and analyzed via HPLC or ELISA to provide a PK profile for the delivered drug. Site evaluations were conducted post delivery to determine skin tolerability. Results Up to 1.5 mL of formulation was infused into swine at a max rate of approximately 0.25 mL/min. A red blotch, the size of the hMTS array, was observed immediately after patch removal, but had faded so as to be almost indistinguishable 10 min post-patch removal. One-mL deliveries of commercial formulations of naloxone hydrochloride and human growth hormone and a formulation of equine anti-tetanus toxin were completed in swine. With few notable differences, the resulting PK profiles were similar to those achieved following subcutaneous injection of these formulations. Conclusions 3M’s hMTS can provide rapid, intradermal delivery of 300–1,500 µL of liquid formulations of small molecules salts and proteins, compounds not typically compatible with passive transdermal delivery. KEY WORDS transdermal drug delivery. microneedles. intradermal. hollow microstructures. MT

    The Effect of Sensory Uncertainty Due to Amblyopia (Lazy Eye) on the Planning and Execution of Visually-Guided 3D Reaching Movements

    Get PDF
    Background: Impairment of spatiotemporal visual processing in amblyopia has been studied extensively, but its effects on visuomotor tasks have rarely been examined. Here, we investigate how visual deficits in amblyopia affect motor planning and online control of visually-guided, unconstrained reaching movements. Methods: Thirteen patients with mild amblyopia, 13 with severe amblyopia and 13 visually-normal participants were recruited. Participants reached and touched a visual target during binocular and monocular viewing. Motor planning was assessed by examining spatial variability of the trajectory at 50–100 ms after movement onset. Online control was assessed by examining the endpoint variability and by calculating the coefficient of determination (R 2) which correlates the spatial position of the limb during the movement to endpoint position. Results: Patients with amblyopia had reduced precision of the motor plan in all viewing conditions as evidenced by increased variability of the reach early in the trajectory. Endpoint precision was comparable between patients with mild amblyopia and control participants. Patients with severe amblyopia had reduced endpoint precision along azimuth and elevation during amblyopic eye viewing only, and along the depth axis in all viewing conditions. In addition, they had significantly higher R 2 values at 70 % of movement time along the elevation and depth axes during amblyopic eye viewing. Conclusion: Sensory uncertainty due to amblyopia leads to reduced precision of the motor plan. The ability to implemen

    A critical role for muscle ring finger-1 in acute lung injury-associated skeletal muscle wasting

    Get PDF
    Rationale: Acute lung injury (ALI) is a debilitating condition associated with severe skeletal muscle weakness thatpersists in humans long after lung injury has resolved. The molecular mechanisms underlying this condition are unknown. Objectives: To identify the muscle-specific molecular mechanisms responsible for muscle wasting in a mouse model of ALI. Methods:Changes in skeletal muscle weight, fiber size, in vivo contractile performance, and expression of mRNAs and proteins encoding muscle atrophy-associated genes for muscle ring finger-1 (MuRF1) and atrogin1 were measured. Genetic inactivation of MuRF1 or electroporation-mediated transduction of miRNA-based short hairpin RNAs targeting either MuRF1 or atrogin1 were used to identify their role in ALI-associated skeletal muscle wasting. Measurements and Main Results: Mice with ALI developed profound muscle atrophy and preferential loss of muscle contractile proteins associatedwith reducedmuscle function in vivo. Although mRNA expression of the muscle-specific ubiquitin ligases, MuRF1 and atrogin1, was increased in ALI mice, only MuRF1 protein levels were up-regulated. Consistent with these changes, suppression of MuRF1 by genetic or biochemical approaches prevented muscle fiber atrophy, whereas suppression of atrogin1 expression was without effect. Despite resolution of lung injury and down-regulation of MuRF1 and atrogin1, force generation in ALI mice remained suppressed. Conclusions: These data show that MuRF1 is responsible for mediating muscle atrophy that occurs during the period of active lung injury inALI mice and that, as in humans, skeletal muscle dysfunction persists despite resolution of lung injury
    corecore