3 research outputs found

    The forward physics facility at the high-luminosity LHC

    Get PDF
    High energy collisions at the High-Luminosity Large Hadron Collider (LHC) produce a large number of particles along the beam collision axis, outside of the acceptance of existing LHC experiments. The proposed Forward Physics Facility (FPF), to be located several hundred meters from the ATLAS interaction point and shielded by concrete and rock, will host a suite of experiments to probe standard model (SM) processes and search for physics beyond the standard model (BSM). In this report, we review the status of the civil engineering plans and the experiments to explore the diverse physics signals that can be uniquely probed in the forward region. FPF experiments will be sensitive to a broad range of BSM physics through searches for new particle scattering or decay signatures and deviations from SM expectations in high statistics analyses with TeV neutrinos in this low-background environment. High statistics neutrino detection will also provide valuable data for fundamental topics in perturbative and non-perturbative QCD and in weak interactions. Experiments at the FPF will enable synergies between forward particle production at the LHC and astroparticle physics to be exploited. We report here on these physics topics, on infrastructure, detector, and simulation studies, and on future directions to realize the FPF's physics potential

    The SIDECAR project: S-IcD registry in European paediatriC and young Adult patients with congenital heaRt defects

    No full text
    Aims Subcutaneous-implantable cardiac defibrillators (S-ICDs) are used increasingly to prevent sudden cardiac death in young patients. This study was set up to gain insight in the indications for S-ICD, possible complications, and their predictors and follow-up results. Methods and results A multicentre, observational, retrospective, non-randomized, standard-of-care registry on S-ICD outcome in young patients with congenital heart diseases (CHDs), inherited arrhythmias (IAs), idiopathic ventricular fibrillation (IVF), and cardiomyopathies (CMPs). Anthropometry was registered as well as implantation technique, mid-term device-related complications, and incidence of appropriate/inappropriate shocks (IASs). Data are reported as median (interquartile range) or mean +/- standard deviation. Eighty-one patients (47% CMPs, 20% CHD, 21% IVF, and 12% IA), aged 15 (14-17) years, with body mass index (BMI) 21.8 +/- 3.8 kg/m(2), underwent S-ICD implantation (primary prevention in 59%). This was performed with two-incision technique in 81% and with a subcutaneous pocket in 59%. Shock and conditional zones were programmed at 250 (200-250) and 210 (180-240) b.p.m., respectively. No intraoperative complications occurred. Follow up was 19 (6-35) months: no defibrillation failure occurred, 17% of patients received appropriate shocks, 13% of patients received IAS (supraventricular tachycardias 40%, T-wave oversensing 40%, and non-cardiac oversensing 20%). Reprogramming, proper drug therapy, and surgical revision avoided further IAS. Complications requiring surgical revision occurred in 9% of patients, with higher risks in patients with three-incision procedures [hazard ratio (HR) 4.3, 95% confidence interval (95% CI) 0.5-34, P = 0.038] and BMI 20 showed better outcome.Developmen
    corecore