216 research outputs found

    Battery state of health estimation with improved generalization using parallel layer extreme learning machine

    Get PDF
    The online estimation of battery state of health (SOH) is crucial to ensure the reliability of the energy supply in electric and hybrid vehicles. An approach for enhancing the generalization of SOH estimation using a parallel layer extreme learning machine (PL-ELM) algorithm is analyzed in this paper. The deterministic and stable PL-ELM model is designed to overcome the drift problem that is associated with some conventional machine learning algorithms; hence, extending the application of a single SOH estimation model over a large set of batteries of the same type. The PL-ELM model was trained with selected features that characterize the SOH. These features are acquired as the discrete variation of indicator variables including voltage, state of charge (SOC), and energy releasable by the battery. The model training was performed with an experimental battery dataset collected at room temperature under a constant current load condition at discharge phases. Model validation was performed with a dataset of other batteries of the same type that were aged under a constant load condition. An optimum performance with low error variance was obtained from the model result. The root mean square error (RMSE) of the validated model varies from 0.064% to 0.473%, and the mean absolute error (MAE) error from 0.034% to 0.355% for the battery sets tested. On the basis of performance, the model was compared with a deterministic extreme learning machine (ELM) and an incremental capacity analysis (ICA)-based scheme from the literature. The algorithm was tested on a Texas F28379D microcontroller unit (MCU) board with an average execution speed of 93 ”s in real time, and 0.9305% CPU occupation. These results suggest that the model is suitable for online applications

    State of Health Estimation of Lithium‐Ion Batteries in Electric Vehicles under Dynamic Load Conditions

    Get PDF
    Among numerous functions performed by the battery management system (BMS), online estimation of the state of health (SOH) is an essential and challenging task to be accomplished periodically. In electric vehicle (EV) applications, accurate SOH estimation minimizes failure risk and improves reliability by predicting battery health conditions. The challenge of accurate estimation of SOH is based on the uncertain dynamic operating condition of the EVs and the complex nonlinear electrochemical characteristics exhibited by the lithium‐ion battery. This paper presents an artificial neural network (ANN) classifier experimentally validated for the SOH estimation of lithium‐ion batteries. The ANN‐based classifier model is trained experimentally at room temperature under dynamic variable load conditions. Based on SOH characterization, the training is done using features such as the relative values of voltage, state of charge (SOC), state of energy (SOE) across a buffer, and the instantaneous states of SOC and SOE. At implementation, due to the slow dynamics of SOH, the algorithm is triggered on a large‐scale periodicity to extract these features into buffers. The features are then applied as input to the trained model for SOH estimation. The classifier is validated experimentally under dynamic varying load, constant load, and step load conditions. The model accuracies for validation data are 96.2%, 96.6%, and 93.8% for the respective load conditions. It is further demonstrated that the model can be applied on multiple cell types of similar specifications with an accuracy of about 96.7%. The performance of the model analyzed with the confusion matrices is consistent with the requirements of the automotive industry. The classifier was tested on a Texas F28379D microcontroller unit (MCU) board. The result shows that an average real‐time execution speed of 8.34 ÎŒs is possible with a negligible memory occupation

    Accelerometer-based SOC estimation methodology for combustion control applied to Gasoline Compression Ignition

    Get PDF
    The European Community's recent decision to suspend the marketing of cars with conventional fossil-fueled internal combustion engines from 2035 requires new solutions, based on carbon-neutral technologies, that ensure equivalent performances in terms of reliability, trip autonomy, refueling times and end-of-life disposal of components compared to those of current gasoline or diesel cars. The use of bio-fuels and hydrogen, which can be obtained by renewable energy sources, coupled with high-efficiency combustion methodologies might allow to reach the carbon neutrality of transports (net-zero carbon dioxide emissions) even using the well-known internal combustion engine technology. Bearing this in mind, experiments were carried out on compression ignited engines running on gasoline (GCI) with a high thermal efficiency which, in the future, could be easily adapted to run on a bio-fuel. Despite the well-reported benefits of GCI engines in terms of efficiency and pollutant emissions, combustion instability hinders the diffusion of these engines for industrial applications. A possible solution to stabilize GCI combustion is the use of multiple injections strategies, typically composed by 2 early injected fuel jests followed by the main injection. The heat released by the combustion of the earlier fuel jets allows to reduce the ignition delay of the main injection, directly affecting both delivered torque and center of combustion. As a result, to properly manage GCI engines, a stable and reliable combustion of the pre-injections is mandatory. In this paper, an estimation methodology of the start of combustion (SOC) position, based on the analysis of the signal coming from an accelerometer sensor mounted on the engine block, is presented (the optimal sensor positioning is also discussed). A strong correlation between the SOC calculated from the accelerometer and that obtained from the analysis of the rate of heat release (RoHR) was identified. As a result, the estimated SOC could be used to feedback an adaptive closed-loop combustion control algorithm, suitable to improve the stability of the whole combustion process

    Electron temperature fluctuation measurements in the pedestal of improved confinement regimes at ASDEX Upgrade

    Get PDF
    US DOE (DE-SC0006419, DE-SC0014264, and DE- SC0017381)EUROfusion Consortium (No. 633053

    Optical and electronic properties of silver nanoparticles embedded in cerium oxide

    Get PDF
    Wide bandgap oxides can be sensitized to visible light by coupling them with plasmonic nanoparticles (NPs). We investigate the optical and electronic properties of composite materials made of Ag NPs embedded within cerium oxide layers of different thickness. The electronic properties of the materials are investigated by X-ray and ultraviolet photoemission spectroscopy, which demonstrates the occurrence of static charge transfers between the metal and the oxide and its dependence on the NP size. Ultraviolet-visible spectrophotometry measurements show that the materials have a strong absorption in the visible range induced by the excitation of localized surface plasmon resonances. The plasmonic absorption band can be modified in shape and intensity by changing the NP aspect ratio and density and the thickness of the cerium oxide film

    From Bed to Bench and Back: TNF-α, IL-23/IL-17A, and JAK-Dependent Inflammation in the Pathogenesis of Psoriatic Synovitis

    Get PDF
    Psoriatic arthritis (PsA) is a chronic inflammatory immune-mediated disease with a burdensome impact on quality of life and substantial healthcare costs. To date, pharmacological interventions with different mechanisms of action, including conventional synthetic (cs), biological (b), and targeted synthetic (ts) disease-modifying antirheumatic drugs (DMARDs), have been proven efficacious, despite a relevant proportion of failures. The current approach in clinical practice and research is typically “predictive”: the expected response is based on stratification according to clinical, imaging, and laboratory data, with a “heuristic” approach based on “trial and error”. Several available therapeutic options target the TNF-α pathway, while others are directed against the IL-23/IL-17A axis. Janus kinase inhibitors (JAKis), instead, simultaneously block different pathways, endowing these drugs with a potentially “broad-spectrum” mechanism of action. It is not clear, however, whether targeting a specific pathway (e.g., TNF-α or the IL-23/IL-17 axis) could result in discordant effects over other approaches. In particular, in the case of “refractory to a treatment” patients, other pathways might be hyperactivated, with opposing, synergistic, or redundant biological significance. On the contrary, refractory states could be purely resistant to treatment as a whole. Since chronic synovitis is one of the primary targets of inflammation in PsA, synovial biomarkers could be useful in depicting specific biological characteristics of the inflammatory burden at the single-patient level, and despite not yet being implemented in clinical practice, these biomarkers might help in selecting the proper treatment. In this narrative review, we will provide an up-to-date overview of the knowledge in the field of psoriatic synovitis regarding studies investigating the relationships among different activated proinflammatory processes suitable for targeting by different available drugs. The final objective is to clarify the state of the art in the field of personalized medicine for psoriatic disease, aiming at moving beyond the current treatment schedules toward a patient-centered approach

    Use of ultrasonography to discriminate psoriatic arthritis from fibromyalgia: A post‐hoc analysis of the ulisse study

    Get PDF
    In psoriatic arthritis (PsA) patients with concomitant chronic widespread pain, the differential diagnosis with fibromyalgia syndrome (FMS) can be challenging. We evaluated whether ultrasound (US) examination of entheseal sites can distinguish pain from (PsA) enthesitis versus FMS. PsA and FMS patients underwent clinical evaluation and gray‐scale (GS; B‐mode) and power Doppler (PD) US examination of the entheses. At least one enthesis with GS‐ and PD‐mode changes was found in 90% and 59.3% of PsA patients (n = 140) and 62.7% and 35.3% of FMS patients (n = 51), respectively. GS and PD identified changes in 49.5% and 19.2% of the 840 PsA entheses and 22.5% and 7.9% of the 306 FMS entheses, respectively. Receiver operating characteristic curve analysis showed an area under the curve of 0.77 and 0.66 for B‐ and PD‐mode, respectively, 3.5 being the best cut‐off GS‐score to discriminate the two conditions. Multivariate regression showed that Achilles and proximal patellar tendon enthesitis (B‐mode) were strongly associated with PsA (odds ratio, ~2). Principal component analysis (B‐mode) confirmed that PsA patients have a higher number of involved entheses and patterns of entheseal involvement than FMS patients. US evaluation of the entheses may help differentiate chronic widespread pain from PsA versus FMS

    Longitudinal changes in cerebral white matter microstructure in newly diagnosed systemic lupus erythematosus patients

    Get PDF
    Objectives. To evaluate longitudinal variations in diffusion tensor imaging (DTI) metrics of different white matter (WM) tracts of newly diagnosed SLE patients, and to assess whether DTI changes relate to changes in clinical characteristics over time.Methods. A total of 17 newly diagnosed SLE patients (19-55 years) were assessed within 24 months from diagnosis with brain MRI (1.5 T Philips Achieva) at baseline, and after at least 12 months. Fractional anisotropy, mean diffusivity (MD), radial diffusivity (RD) and axial diffusivity values were calculated in several normal-appearing WM tracts. Longitudinal variations in DTI metrics were analysed by repeated measures analysis of variance. DTI changes were separately assessed for 21 WM tracts. Associations between longitudinal alterations of DTI metrics and clinical variables (SLEDAI-2K, complement levels, glucocorticoid dosage) were evaluated using adjusted Spearman correlation analysis.Results. Mean MD and RD values from the normal-appearing WM significantly increased over time (P = 0.019 and P = 0.021, respectively). A significant increase in RD (P = 0.005) and MD (P = 0.012) was found in the left posterior limb of the internal capsule; RD significantly increased in the left retro-lenticular part of the internal capsule (P = 0.013), and fractional anisotropy significantly decreased in the left corticospinal tract (P = 0.029). No significant correlation was found between the longitudinal change in DTI metrics and the change in clinical measures.Conclusion. Increase in diffusivity, reflecting a compromised WM tissue microstructure, starts in initial phases of the SLE disease course, even in the absence of overt neuropsychiatric (NP) symptoms. These results indicate the importance of monitoring NP involvement in SLE, even shortly after diagnosis.Neuro Imaging Researc
    • 

    corecore