498 research outputs found
Müllerian Serous Cystadenoma of the Scrotum Following Orchiopexy
A 24-year-old man presented himself with a nodular lesion of about 1 cm diameter at the site of a previous orchiopexy associated with surgery for cryptorchism. Histopathology revealed the lesion to be adenomatous and confined to the scrotum. Histological and immunohistological features were not consistent neither with median raphe cysts or cutaneous adenomas nor with the intrascrotal adenomas of the rete testis, epididymis, nor with (malignant) mesotheliomas. However, the lesion did compare well with serous (papillary) cystadenomas of the testis or paratestis. These adenomas are thought to originate in remnants of the Müllerian system or of peritoneal lining altered by Müllerian metaplasia. This implies that the scrotal adenoma may have developed from an implant of such elements during orchiopexy 14 years ago. Complete excision of the lesion appears to be an adequate therapy
Numerical and Experimental Study of Natural Convection Air Flow in a Solar Tower Dryer
This work focuses on the study of the flow of air in natural convection in a solar tower of small size. The behavior of air in the tower, considered as a solar dryer, provides information on the amount of heat absorbed by the air upon entry into the collector. A theoretical approach allows us to theoretically simulate the flow by using a mathematical model characterizing the physical parameters of the system during a daily sunshine. An analysis of this phenomenon is made and results are obtained
Optical and Thermal Performance Analysis of a Steady Spherical Collector with a Crescent-shaped Rotating Absorber
In this paper, optical analysis of spherical concentrator is made to determine the local and the global geometric concentration, as knowing the geometric concentration of a system can help predict what temperatures can possibly be obtained with it.This leads to conclude that spherical collectors may produce higher temperatures than parabolic trough, and they could even be sharply improved by using a mixt cylindrical and cavity (or flat) absorber.
A craft prototype of a steady spherical concentrator made with concreteand having a smooth inner surface mapped with mirror tape is presented. Its absorber is made with blacken steel sheets and shaped like a moon crescent to be aligned with the declination plan and to avoid motorization for the tracking of the sun from East to West. Experimental measurements lead to temperatures reaching 686°C on the curve of the least diffusion, and 252°C in the absorber oven-like reservoir. Overall, the resultsuggests higher potentialities of spherical collectors,which also show possibility of use with much reduced tracking system and less vulnerability to bad weather
Measurement of Intrinsic Dirac Fermion Cooling on the Surface of the Topological Insulator Bi_2Se_3 Using Time-Resolved and Angle-Resolved Photoemission Spectroscopy
We perform time- and angle-resolved photoemission spectroscopy of a prototypical topological insulator (TI) Bi_2Se_3 to study the ultrafast dynamics of surface and bulk electrons after photoexcitation. By analyzing the evolution of surface states and bulk band spectra, we obtain their electronic temperature and chemical potential relaxation dynamics separately. These dynamics reveal strong phonon-assisted surface-bulk coupling at high lattice temperature and total suppression of inelastic scattering between the surface and the bulk at low lattice temperature. In this low temperature regime, the unique cooling of Dirac fermions in TI by acoustic phonons is manifested through a power law dependence of the surface temperature decay rate on carrier density
The need for allele mining: perspectives of the System-wide Genetic Resources Programme (SGRP)
The SGRP is a consortium of all CGIAR gene banks. These banks aim to (1) conserve
diversity efficiently, including and especially rare alleles and genotypes; (2) ensure efficient
use of collection by delivering appropriately selected subsets of germplasm to users,
maximizing the chance of giving users the set of alleles or genotypes that they need; and (3)
ensure that the entire collection remains available for use. The SGRP exists to ensure a
consistent, integrated, system-wide approach to the efficient achievement of these goals
Performance of EUS-FNA for mediastinal lymphadenopathy: impact on patient management and costs in low-volume EUS centers
BACKGROUND: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of mediastinal lymphadenopathy has been shown to be a valuable diagnostic tool in high-volume EUS centers (≥ 50 mediastinal EUS-FNA/endoscopist/year). Our goal was to assess the diagnostic accuracy of EUS-FNA and its impact on clinical management and costs in low-volume EUS centers ( <50 mediastinal EUS-FNA/endoscopist/year). METHODS: Consecutive patients referred to two Dutch endoscopy centers in the period 2002-2008 for EUS-FNA of mediastinal lymphadenopathy were reviewed. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. The impact of EUS-FNA on clinical management was subdivided into a positive impact by providing (1) adequate cytology that influenced the decision to perform surgery or (2) a diagnosis of a benign inflammatory disorder, and a negative impact which was subdivided into (1) false-negative or inconclusive cytology or (2) an adequate cytological diagnosis that did not influence patient management. Costs of an alternative diagnostic work-up without EUS-FNA, as established by an expert panel, were compared to costs of the actual work-up. RESULTS: In total, 213 patients (71% male, median age= 61 years, range = 23-88 years) underwent EUS-FNA. Sensitivity, specificity, and negative and positive predictive values were 89%, 100%, 80%, and 100%, respectively. EUS-FNA had a positive impact on clinical management in 84% of cases by either influencing the decision to perform surgery (49%) or excluding malignant lymphadenopathy (35%), and a negative impact in 7% of cases because of inadequate (3%) or false-negative (4%) cytology. In 9% of cases, EUS-FNA was performed without an established indication. Two nonfatal perforations occurred (0.9%). Total cost reduction was €100,593, with a mean cost reduction of €472 (SD = €607) per patient. CONCLUSIONS: Mediastinal EUS-FNA can be performed in low-volume EUS centers without compromising diagnostic accuracy. Moreover, EUS-FNA plays an important role in the management of patients with mediastinal lymphadenopathy and reduces total diagnostic cost
Phonon-driven spin-Floquet magneto-valleytronics in MoS2
Two-dimensional materials equipped with strong spin-orbit coupling can display novel electronic, spintronic, and topological properties originating from the breaking of time or inversion symmetry. A lot of interest has focused on the valley degrees of freedom that can be used to encode binary information. By performing ab initio time-dependent density functional simulation on MoS2, here we show that the spin is not only locked to the valley momenta but strongly coupled to the optical E '' phonon that lifts the lattice mirror symmetry. Once the phonon is pumped so as to break time-reversal symmetry, the resulting Floquet spectra of the phonon-dressed spins carry a net out-of-plane magnetization (approximate to 0.024 mu(B) for single-phonon quantum) even though the original system is non-magnetic. This dichroic magnetic response of the valley states is general for all 2H semiconducting transition-metal dichalcogenides and can be probed and controlled by infrared coherent laser excitation
The Pan-STARRS 1 discoveries of five new neptune trojans
In this work we report the detection of seven Neptune Trojans (NTs) in the
Pan-STARRS 1 (PS1) survey. Five of these are new discoveries, consisting of
four L4 Trojans and one L5 Trojan. Our orbital simulations show that the L5
Trojan stably librates for only several million years. This suggests that the
L5 Trojan must be of recent capture origin. On the other hand, all four new L4
Trojans stably occupy the 1:1 resonance with Neptune for more than 1 Gyr. They
can, therefore, be of primordial origin. Our survey simulation results show
that the inclination width of the Neptune Trojan population should be between
and at 95% confidence, and most likely . In this paper, we describe the PS1 survey, the Outer Solar System
pipeline, the confirming observations, and the orbital/physical properties of
the new Neptune Trojans.Comment: 24 pages, 6 figures, AJ accepte
Pronounced Shape Change Induced by Quasiparticle Alignment
Mean lifetimes of high-spin states of 74Kr have been determined using the Doppler-shift attenuation method. The high-spin states were studied using the 40Ca(40Ca,α2p) reaction at a beam energy of 160 MeV with the GASP γ-ray spectrometer. The ground-state band and negative parity side band show the presence of three different configurations in terms of transitional quadrupole deformations. A dramatic shape change was found along the ground-state band after the S-band crossing. The deduced quadrupole deformation changes are well reproduced by cranked Woods-Saxon Strutinsky calculations
- …