43 research outputs found

    Design and optimization of a wideband impact mode piezoelectric power generator

    Get PDF
    This paper proposes a new design of an impact mode piezoelectric power generator that is able to operate in a wide frequency bandwidth by using a round piezoelectric ceramic as the energy converter. The evaluation results show that the output of the power generator can be optimized by implementing a so-called indirect impact configuration. To realize this type of configuration, a shim plate is placed between the piezoelectric ceramic and the hitting structure. At a certain base excitation frequency, the output efficiency of this configuration increases to about 4.3 times that of the direct impact configuration. Furthermore, it is demonstrated that the designated power generator is able to generate electric energy up to approximately 1.57 mJ within 120 s from the vibration of a moving vehicle

    Study of the effect of mechanical impact parameters on an impact-mode piezoelectric ceramic power generator

    Get PDF
    This paper presents an analytical and experimental study on the effect of mechanical impact parameters on impact-mode piezoelectric ceramic power generators. The parameters are the velocity and mass. The method of analysis is based on a weight drop experiment. The results show that the peak of the instantaneous output voltage is proportional to the impact velocity, and for the output power, it is in a straight line relationship with the same parameter. For the same velocity of impact, the advantage of using heavy objects is clear because its momentum and the impact force are higher. However, an adjustment in the velocity of impact is found to be more effective for higher instantaneous output power than the mass. This finding is supported by the output power that is generated by a 4-g steel ball with a momentum of 4.34 gm/s, which is almost 300% higher than that of an 8-g steel ball for the same momentum. The frequency responses of a vibration-based impact-mode piezoelectric ceramic power generator also support the same conclusion

    The Effect of the Parameters of a Vibration-Based Impact Mode Piezoelectric Power Generator

    Get PDF
    This study reports the effects of the parameters of a vibration-based impactmode piezoelectric power generator. First, an evaluation of the effects of the impact parameters, the mass, and the impact velocity is presented. It is found that the output voltage of the piezoelectric device in impactmode is directly proportional to the velocity,whereas the output power is equal to a quadratic function of the same variable. For the same impact momentum, the effect of the velocity in generating a higher peak output is dominant compared with the mass. Second, the vibration-based impact mode piezoelectric power generator is discussed. The experimental results show that a wider operating frequency bandwidth of the output power can be achieved with the preloading configuration. However, regardingmagnitude, due to the high velocity of impact, the configurationwith a gap between the tip and the piezoelectric device produces a higher output

    Shape Effect of Piezoelectric Energy Harvester on Vibration Power Generation

    Get PDF
    Vibration energy harvesting is widely recognized as the useful technology for saving energy. The piezoelectric energy harvesting device is one of energy harvester and is used to operate certain types of MEMS devices. Various factors influence the energy regeneration efficiency of the lead zirconate titanate piezoelectric (PZT) devices in converting the mechanical vibration energy to the electrical energy. This paper presents the analytical and experimental evaluation of energy regeneration efficiency of PZT devices through impedance matching method and drop-weight experiments to different shape of PZT devices. The results show that the impedance matching method has increased the energy regeneration efficiency while triangular shape of PZT device produce a stable efficiency in the energy regeneration. Besides that, it becomes clear that the power, energy and subsequently efficiency of the triangular plate are higher than those of the rectangular plate under the condition of the matching impedance and the same PZT area

    Conversion of FeCo from soft to hard magnetic material by lattice engineering and nanopatterning

    Get PDF
    The development of magnetic materials with large uniaxial magnetic anisotropy (K-u) and high saturation magnetization has attracted much attention in various areas such as high-density magnetic storage, spintronic devices, and permanent magnets. Although FeCo alloys with the body-centred cubic structure exhibit the highest M-s among all transition metal alloys, their low K-u and coercivity (H-c) make them unsuitable for these applications. However, recent first-principles calculations have predicted large K-u for the FeCo films with the body-centred tetragonal structure. In this work, we experimentally investigated the hard magnetic properties and magnetic domain structures of nanopatterned FeCo alloy thin films. As a result, a relatively large value of the perpendicular uniaxial magnetic anisotropy K-u = 2.1 x 10(6) J.m(-3) was obtained, while the H-c of the nanopatterned FeCo layers increased with decreasing dot pattern size. The maximum H-c measured in this study was 4.8 x 10(5) A.m(-1), and the corresponding value of mu H-0(c) was 0.60 T, where mu(0) represented the vacuum permeability

    Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).

    Get PDF
    Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≄1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≀6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)

    Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.

    Get PDF
    BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362

    Über die Wirkung des Vitamin C bei Nekrotischer Diphtherie

    No full text
    corecore