462 research outputs found

    Radiation-Induced Heart Disease: A Clinical Update

    Get PDF
    Cardiovascular diseases and cancer are the two leading causes of morbidity and mortality worldwide. Improvement in cancer therapy has led to increasing number of cancer survivors, some of whom may suffer from adverse cardiovascular effects of radiation therapy. Longterm followup is essential, as the cardiac complication may manifest years after completion of radiation therapy. In this paper, we have discussed the cardiovascular effects of radiation therapy

    Rotational and centration stability of an aspheric intraocular lens with a simulated toric design

    Get PDF
    Purpose: To assess the stability of the Akreos AO intraocular lens (IOL) platform with a simulated toric design using objective image analysis. Setting: Six hospital eye clinics across Europe. Methods: After implantation in 1 eye of patients, IOLs with orientation marks were imaged at 1 to 2 days, 7 to 14 days, 30 to 60 days, and 120 to 180 days. The axis of rotation and IOL centration were objectively assessed using validated image analysis. Results: The study enrolled 107 patients with a mean age of 69.9 years ± 7.7 (SD). The image quality was sufficient for IOL rotation analysis in 91% of eyes. The mean rotation between the first day postoperatively and 120 to 180 days was 1.93 ± 2.33 degrees, with 96% of IOLs rotating fewer than 5 degrees and 99% rotating fewer than 10 degrees. There was no significant rotation between visits and no clear bias in the direction of rotation. In 71% of eyes, the dilation and image quality was sufficient for image analysis of centration. The mean change in centration between 1 day and 120 to 180 days was 0.21 ± 0.11 mm, with all IOLs decentering less than 0.5 mm. There was no significant decentration between visits and no clear bias in the direction of the decentration. Conclusion: Objective analysis of digital retroillumination images taken at different postoperative periods shows the aspheric IOL platform was stable in the eye and is therefore suitable for the application of a toric surface to correct corneal astigmatism

    Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses

    Get PDF
    Aim: To better understand the phenomenon of dysphotopsia in patients implanted with multifocal intraocular lenses (IOLs). Methods: Forty-five patients (aged 61.8±8.9 years) implanted bilaterally with Tecnis ZM900 (diffractive multifocal), Lentis Mplus MF30 (segmented refractive multifocal) or Softec-1 (monofocal) IOLs (each n=15) 4–6 months previously and who had achieved a good surgical outcome were examined. Each reported their dysphotopsia symptoms subjectively, identified its form (EyeVisPod illustrations), quantified retinal straylight (C-Quant) and halo perception (Aston halometer). Retinal straylight and halometry was repeated by a second masked clinician to determine interobserver repeatability. Results: Subjective dysphotopsia ratings were able to differentiate Tecnis ZM900 from Lentis Mplus MF30 (p0.10) quantification or between straylight and the halo area (p>0.30). Conclusions: Multifocal IOLs induce symptoms of dysphotopsia. Straylight did not differentiate between IOL designs, however halometry identified clear differences in light scatter due to the IOL optics. Whereas, subjective rating of overall dysphotopsia are not strongly associated with straylight or halo perception, the halometry polar diagram reflected the subjective descriptions of dysphotopsia

    Influence of Crohn’s disease related polymorphisms in innate immune function on ileal microbiome

    Get PDF
    We have previously identified NOD2 genotype and inflammatory bowel diseases (IBD) phenotype, as associated with shifts in the ileal microbiome (“dysbiosis”) in a patient cohort. Here we report an integrative analysis of an expanded number of Crohn's disease (CD) related genetic defects in innate immune function (NOD2, ATG16L1, IRGM, CARD9, XBP1, ORMDL3) and composition of the ileal microbiome by combining the initial patient cohort (Batch 1, 2005–2010, n = 165) with a second consecutive patient cohort (Batch 2, 2010–2012, n = 118). These combined patient cohorts were composed of three non-overlapping phenotypes: 1.) 106 ileal CD subjects undergoing initial ileocolic resection for diseased ileum, 2.) 88 IBD colitis subjects without ileal disease (predominantly ulcerative colitis but also Crohn’s colitis and indeterminate colitis, and 3.) 89 non-IBD subjects. Significant differences (FDR C. difficile infection, and NOD2 genotype on ileal dysbiosis in the expanded analysis. The relative abundance of the Proteobacteria phylum was positively associated with ileal CD and colitis phenotypes, but negatively associated with NOD2R genotype. Additional associations with ORMDL3 and XBP1 were detected at the phylum/subphylum level. IBD medications, such as immunomodulators and anti-TNFα agents, may have a beneficial effect on reversing dysbiosis associated with the IBD phenotype. Exploratory analysis comparing microbial composition of the disease unaffected region of the resected ileum between 27 ileal CD patients who subsequently developed endoscopic recurrence within 6–12 months versus 34 patients who did not, suggested that microbial biomarkers in the resected specimen helped stratify patients with respect to risk of post-surgical recurrence.</div

    Graphene oxide as an efficient photocatalyst for photocatalytic reduction of CO2 into solar fuel

    Get PDF
    Photocatalytic reduction of CO2 into solar fuel such as methane and methanol, is an attractive approach to simultaneously solve the energy crisis and global warming problem. Herein, comparative photocatalytic activity of graphene oxide nanosheets have been investigated for photocatalytic reduction of CO2 into methane and methanol in continuous gas and liquid phase photoreactor system. The graphene oxide sheets were prepared according to Tour's method. The chemical composition and optical properties was evaluated through XPS and UV-vis spectroscopy. Graphene oxide nanosheets exhibited maximum amount of 224.87 μmol/g.h methanol and 14.8 μmol/g.h methane in liquid and gas phase system, respectively. Higher yield of methanol in liquid phase compared to methane in gaseous system can be attributed to dispersion of graphene oxide sheets in water. Hence, graphene oxide nanosheets are efficient photocatalyst for CO2 reduction into methanol. Nevertheless, further research is essential to improve the photostability of graphene oxide sheets for real application of photocatalytic CO2 reduction

    Small grain cereal–clover mixtures for forage production

    Get PDF
    Fresh forages are the cheapest source of animal feed in world. Small grain cereals (SGC) are the most commonly used fresh forages or ensiled forage. Clovers are the perennial legumes that offer quality forage but their initial dry matter (DM) yield is low. Usually, SGC and clover are sown in mixtures to draw benefits from greater Cut-1 DM yield of cereals and biological nitrogen (N) fixation of clovers. However, mixtures are difficult to manage, compared to monoculture owing to differences in their growth pattern, temporal, spatial and physical requirements. In this review, SGC-clover mixtures are analyzed for their potential herbage DM yield and quality of the produce. Effect of various management factors on the productivity of forage mixtures are well documented. Decisions in managing mixtures, like choice of cereal and cutting time and how they affect the value of the final produce is reviewed. Besides decision, effect of relative proportion and spatial arrangement of intercrops is also deliberated. Special attention is paid to the competition between SGC and clovers and its impact on clover suppression in mixture. At the end conclusions are drawn to optimize production from mixtures

    Multifocal intraocular lens differentiation using defocus curves

    Get PDF
    Purpose: To determine the most appropriate analysis technique for the differentiation of multifocal intraocular lens (MIOL) designs using defocus curve assessment of visual capability.Methods:Four groups of fifteen subjects were implanted bilaterally with either monofocal intraocular lenses, refractive MIOLs, diffractive MIOLs, or a combination of refractive and diffractive MIOLs. Defocus curves between -5.0D and +1.5D were evaluated using an absolute and relative depth-of-focus method, the direct comparison method and a new 'Area-of-focus' metric. The results were correlated with a subjective perception of near and intermediate vision. Results:Neither depth-of-focus method of analysis were sensitive enough to differentiate between MIOL groups (p>0.05). The direct comparison method indicated that the refractive MIOL group performed better at +1.00, -1.00 and -1.50 D and worse at -3.00, -3.50, -4.00 and -5.00D compared to the diffractive MIOL group (

    Mechanism of action of the tetraflex accommodative intraocular lens

    Get PDF
    PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag

    Tablet App halometer for the assessment of dysphotopsia

    Get PDF
    Purpose To assess the validity and repeatability of the Aston Halometer. Setting University clinic, United Kingdom. Design Prospective, repeated-measures experimental study. Methods The halometer comprises a bright light-emitting-diode (LED) glare source in the center of an iPad4. Letters subtending 0.21° (∼0.3 logMAR) were moved centrifugally from the LED in 0.05 degree steps in 8 orientations separated by 45 degrees for each of 4 contrast levels (1000, 500, 100, and 25 Weber contrast units [Cw]) in random order. Bangerter occlusion foils were inserted in front of the right eye to simulate monocular glare conditions in 20 subjects (mean age 27.7 ± 3.1 years). Subjects were positioned 2 meters from the screen in a dark room with the iPad controlled from an iPhone via Bluetooth operated by the researcher. The C-Quant straylight meter was also used with each of the foils to measure the level of straylight over the retina. Halometry and straylight repeatability was assessed at a second visit. Results Halo size increased with the different occlusion foils and target contrasts (F = 29.564, P <.001) as expected and in a pattern similar to straylight measures (F = 80.655, P <0.001). Lower contrast letters showed better sensitivity but larger glare-obscured areas, resulting in ceiling effects caused by the screen's field-of-view, with 500 Cw being the best compromise. Intraobserver and interobserver repeatability of the Aston Halometer was good (500Cw: 0.84 to 0.93 and 0.53 to 0.73) and similar to the straylight meter. Conclusion The halometer provides a sensitive, repeatable way of quantifying a patient-recognized form of disability glare in multiple orientations to add objectivity to subjectively reported discomfort glare
    corecore