96 research outputs found

    Hydrogels based on poly(vinyl alcohol) for cartilage substitution

    Get PDF
    Abstract in proceedings of the Fourth International Congress of CiiEM: Health, Well-Being and Ageing in the 21st Century, held at Egas Moniz’ University Campus in Monte de Caparica, Almada, from 3–5 June 2019.This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.info:eu-repo/semantics/publishedVersio

    Tribomechanical Comparison between PVA Hydrogels Obtained Using Different Processing Conditions and Human Cartilage

    Get PDF
    Designing materials for cartilage replacement raises several challenges due to the complexity of the natural tissue and its unique tribomechanical properties. Poly(vinyl alcohol) (PVA) hydrogels have been explored for such purpose since they are biocompatible, present high chemical stability, and their properties may be tailored through different strategies. In this work, the influence of preparation conditions of PVA hydrogels on its morphology, water absorption capacity, thermotropic behavior, mechanical properties, and tribological performance was evaluated and compared with those of human cartilage (HC). The hydrogels were obtained by cast-drying (CD) and freeze-thawing (FT), in various conditions. It was found that the method of preparation of the PVA hydrogels critically affects their microstructure and performance. CD gels presented a denser structure, absorbed less water, were stiffer, dissipated less energy, and withstood higher loads than FT gels. Moreover, they led to friction coefficients against stainless steel comparable with those of HC. Overall, CD hydrogels had a closer performance to natural HC, when compared to FT ones.info:eu-repo/semantics/publishedVersio

    Controlled drug release from hydrogels for contact lenses: drug partitioning and diffusion

    Get PDF
    Optimization of drug delivery from drug loaded contact lenses assumes understanding the drug transport mechanisms through hydrogels which relies on the knowledge of drug partition and diffusion coefficients. We chose, as model systems, two materials used in contact lens, a poly-hydroxyethylmethacrylate (pHEMA) based hydrogel and a silicone based hydrogel, and three drugs with different sizes and charges: chlorhexidine, levofloxacin and diclofenac. Equilibrium partition coefficients were determined at different ionic strength and pH, using water (pH 5.6) and PBS (pH 7.4). The measured partition coefficients were related with the polymer volume fraction in the hydrogel, through the introduction of an enhancement factor following the approach developed by the group of C. J. Radke (Kotsmar et al., 2012; Liu et al., 2013). This factor may be decomposed in the product of three other factors EHS, Eel and Ead which account for, respectively, hard-sphere size exclusion, electrostatic interactions, and specific solute adsorption. While EHS and Eel are close to 1, Ead > > 1 in all cases suggesting strong specific interactions between the drugs and the hydrogels. Adsorption was maximal for chlorhexidine on the silicone based hydrogel, in water, due to strong hydrogen bonding. The effective diffusion coefficients, De, were determined from the drug release profiles. Estimations of diffusion coefficients of the non-adsorbed solutes D = De × Ead allowed comparison with theories for solute diffusion in the absence of specific interaction with the polymeric membrane.info:eu-repo/semantics/publishedVersio

    Diffusion-based design of multi-layered ophthalmic lenses for controlled drug release

    Get PDF
    The study of ocular drug delivery systems has been one of the most covered topics in drug delivery research. One potential drug carrier solution is the use of materials that are already commercially available in ophthalmic lenses for the correction of refractive errors. In this study, we present a diffusion-based mathematical model in which the parameters can be adjusted based on experimental results obtained under controlled conditions. The model allows for the design of multi-layered therapeutic ophthalmic lenses for controlled drug delivery. We show that the proper combination of materials with adequate drug diffusion coefficients, thicknesses and interfacial transport characteristics allows for the control of the delivery of drugs from multi-layered ophthalmic lenses, such that drug bursts can be minimized, and the release time can be maximized. As far as we know, this combination of a mathematical modelling approach with experimental validation of non-constant activity source lamellar structures, made of layers of different materials, accounting for the interface resistance to the drug diffusion, is a novel approach to the design of drug loaded multi-layered contact lenses.info:eu-repo/semantics/publishedVersio

    Interaction of fluorescence of resin cements with glass ceramics

    Get PDF
    Poster presented at the 24th Annual Meeting of the Portuguese Dental Association, Lisbon, 12-14 November 2015.Poster apresentado no XXIV Congresso da Ordem dos Médicos Dentistas, Lisboa, 12-14 Novembro 2015."Introduction: In aesthetic rehabilitations, we must take into account the primary and secondary optical properties. Objectives: To evaluate the emission intensity of fluorescence between resin cement and glass-ceramic. Materials and Methods: two self-adhesive resin cements were used, as well as glass ceramic discs and composite resin. The ceramic cylinders were cut with a thickness of 1 and 0.5 millimeters and were bonded to composite resin discs with 0.5mm and polymerized for 40 seconds, for a total of n = 100. Fluorescence spectrums were obtained in a spectrofluorometer at a wavelength of 380 nanometers. Statistical analysis was performed using Student's t-test and one-way ANOVA, for a significance of p <0.05. Results: The samples of the control group were the ones who exhibited lower fluorescence with values of 1.99E13 a.u. in a thickness of 0.5mm and 2.95E13 a.u. in a thickness of 1 mm. In the samples of 1mm, all groups have similar values of fluorescence emission. In samples with 0.5mm, there are significant differences between each group (p <0.001) , in which the SCT group has higher fluorescence emission (1.06E14 a.u.). Conclusions: The thickness of the ceramic influences the final emission intensity of fluorescence. The emission intensity of fluorescence of the resin cements influences the final fluorescence of the glass ceramic. Clinical Implications: This study reveals the importance of the choice of the cement and ceramic thickness in a full ceramic rehabilitation.

    Effect of pH of H2O2 solutions on the morphology and wear resistance of human dental enamel: an AFM study

    Get PDF
    Abstract in proceedings of the Fourth International Congress of CiiEM: Health, Well-Being and Ageing in the 21st Century, held at Egas Moniz’ University Campus in Monte de Caparica, Almada, from 3–5 June 2019.This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.info:eu-repo/semantics/publishedVersio

    Physically crosslinked polyvinyl alcohol hydrogels as synthetic cartilage materials

    Get PDF
    Abstract in proceedings of the Fourth International Congress of CiiEM: Health, Well-Being and Ageing in the 21st Century, held at Egas Moniz’ University Campus in Monte de Caparica, Almada, from 3–5 June 2019.This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.info:eu-repo/semantics/publishedVersio

    Ageing effects on the wettability behavior of laser textured silicon

    Get PDF
    In the present work we investigate the ageing of acid cleaned femtosecond laser textured silicon surfaces. Changes in the surface structure and chemistry were analysed by Rutherford backscattering spectrometry (RBS) and X-ray photoelectron spectroscopy (XPS), in order to explain the variation with time of the water contact angles of the laser textured surfaces. It is shown that highly hydrophobic silicon surfaces are obtained immediately after laser texturing and cleaning with acid solutions (water contact angle >120 degrees). However these surfaces are not stable and ageing leads to a decrease of the water contact angle which reaches a value of 80 degrees. XPS analysis of the surfaces shows that the growth of the native oxide layer is most probably responsible for this behavior. (C) 2010 Elsevier B.V. All rights reserved

    Influence of the liquid phase content and presence of hydroxypropyl methyl cellulose on the properties of a calcium phosphate bone cement

    Get PDF
    Abstract in proceedings of the Fourth International Congress of CiiEM: Health, Well-Being and Ageing in the 21st Century, held at Egas Moniz’ University Campus in Monte de Caparica, Almada, from 3–5 June 2019.This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.info:eu-repo/semantics/publishedVersio

    Possible scale invariant linear magnetoresistance in pyrochlore iridates Bi2Ir2O7

    Get PDF
    We report the observation of a linear magnetoresistance in single crystals and epitaxial thin films of the pyrochlore iridate Bi2Ir2O7. The linear magnetoresistance is positive and isotropic at low temperatures, without any sign of saturation up to 35 T. As temperature increases, the linear field dependence gradually evolves to a quadratic field dependence. The temperature and field dependence of magnetoresistance of Bi2Ir2O7 bears strikingly resemblance to the scale invariant magnetoresistance observed in the strange metal phase in high Tc cuprates. However, the residual resistivity of Bi2Ir2O7 is more than two orders of magnitude higher than the curpates. Our results suggest that the correlation between linear magnetoresistance and quantum fluctuations may exist beyond high temperature superconductors
    • …
    corecore