5,113 research outputs found

    Experimental Techniques

    Get PDF

    Visual Control of Altitude in Flying Drosophila

    Get PDF
    Unlike creatures that walk, flying animals need to control their horizontal motion as well as their height above the ground. Research on insects, the first animals to evolve flight, has revealed several visual reflexes that are used to govern horizontal course. For example, insects orient toward prominent vertical features in their environment [1], [2], [3], [4] and [5] and generate compensatory reactions to both rotations [6] and [7] and translations [1], [8], [9], [10] and [11] of the visual world. Insects also avoid impending collisions by veering away from visual expansion [9], [12], [13] and [14]. In contrast to this extensive understanding of the visual reflexes that regulate horizontal course, the sensory-motor mechanisms that animals use to control altitude are poorly understood. Using a 3D virtual reality environment, we found that Drosophila utilize three reflexes—edge tracking, wide-field stabilization, and expansion avoidance—to control altitude. By implementing a dynamic visual clamp, we found that flies do not regulate altitude by maintaining a fixed value of optic flow beneath them, as suggested by a recent model [15]. The results identify a means by which insects determine their absolute height above the ground and uncover a remarkable correspondence between the sensory-motor algorithms used to regulate motion in the horizontal and vertical domains

    Patients associations : new elements in the medical decision

    Get PDF

    Experimental application of sum rules for electron energy loss magnetic chiral dichroism

    Full text link
    We present a derivation of the orbital and spin sum rules for magnetic circular dichroic spectra measured by electron energy loss spectroscopy in a transmission electron microscope. These sum rules are obtained from the differential cross section calculated for symmetric positions in the diffraction pattern. Orbital and spin magnetic moments are expressed explicitly in terms of experimental spectra and dynamical diffraction coefficients. We estimate the ratio of spin to orbital magnetic moments and discuss first experimental results for the Fe L_{2,3} edge.Comment: 11 pages, 2 figure

    Potential use of pepper waste and microalgae Spirulina sp. for bioelectricity generation

    Get PDF
    The research aimed to generate bioelectricity using pepper waste and the microalgae Spirulina sp by a double-chamber microbial fuel cell (dcMFC). A dcMFC was constructed with Cu and Zn electrodes, where organic waste and microalgae were placed in the anodic and cathodic chambers, respectively. Also, electrochemical parameters were measured for 35 days. Finally, possible electrogenic microorganisms were isolated and identified. It was possible to generate maximum values of current (6.04414 ± 0.2145 mA) and voltage (0.77328 ± 0.213 V). The maximum conductivity value was 134.1636 ± 7.121 mS/cm, while the internal resistance value was 83.784 . The values of power and current density reached were 584.45 ± 19.14 mW/cm 2 and 5.983 A/cm 2, respectively. The optimal operating pH was 4.59 ± 0.14. From the microbial growth on the anode, the yeast Yarrowia phangngaensis (1) and Pseudomonas stutzeri (2) were identified, which may be involved in the transfer of electrons to the electrode. In conclusion, it was possible to generate clean energy in a laboratory-scale dcMFC when pepper waste and Spirulina sp. were used. These results are promising because organic waste can generate sustainable and environmentally friendly energy

    Energy Linearity and Resolution of the ATLAS Electromagnetic Barrel Calorimeter in an Electron Test-Beam

    Get PDF
    A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam impinged at one point corresponding to a pseudo-rapidity of eta=0.687 and an azimuthal angle of phi=0.28 in the ATLAS coordinate system. A detailed study of several effects biasing the electron energy measurement allowed an energy reconstruction procedure to be developed that ensures a good linearity and a good resolution. Use is made of detailed Monte Carlo simulations based on Geant which describe the longitudinal and transverse shower profiles as well as the energy distributions. For electron energies between 15 GeV and 180 GeV the deviation of the measured incident electron energy over the beam energy is within 0.1%. The systematic uncertainty of the measurement is about 0.1% at low energies and negligible at high energies. The energy resolution is found to be about 10% sqrt(E) for the sampling term and about 0.2% for the local constant term

    Mathematical modelling of liquid meniscus shape in cylindrical micro-channel for normal and micro gravity conditions

    Full text link
    Mathematical model of liquid meniscus shape in cylindrical micro-channel of the separator unit of condensing/separating system is presented. Moving liquid meniscus in the 10 ÎĽm cylindrical microchannel is used as a liquid lock to recover the liquid obtained by condensation from the separators. The main goal of the liquid locks to prevent penetration of a gas phase in the liquid line at the small flow rate of the condensate and because of pressure fluctuations in the vapor-gas-liquid loop. Calculation of the meniscus shape has been performed for liquid FC-72 at different values of pressure difference gas - liquid and under normal and micro gravity conditions

    The Minimal Supersymmetric Standard Model: Group Summary Report

    Get PDF
    CONTENTS: 1. Synopsis, 2. The MSSM Spectrum, 3. The Physical Parameters, 4. Higgs Boson Production and Decays, 5. SUSY Particle Production and Decays, 6. Experimental Bounds on SUSY Particle Masses, 7. References.Comment: 121 pages, latex + epsfig, graphicx, axodraw, Report of the MSSM working group for the Workshop "GDR-Supersym\'etrie",France. Rep. PM/98-4

    Position resolution and particle identification with the ATLAS EM calorimeter

    Full text link
    In the years between 2000 and 2002 several pre-series and series modules of the ATLAS EM barrel and end-cap calorimeter were exposed to electron, photon and pion beams. The performance of the calorimeter with respect to its finely segmented first sampling has been studied. The polar angle resolution has been found to be in the range 50-60 mrad/sqrt(E (GeV)). The neutral pion rejection has been measured to be about 3.5 for 90% photon selection efficiency at pT=50 GeV/c. Electron-pion separation studies have indicated that a pion fake rate of (0.07-0.5)% can be achieved while maintaining 90% electron identification efficiency for energies up to 40 GeV.Comment: 32 pages, 22 figures, to be published in NIM
    • …
    corecore