890 research outputs found
A hybrid Constraint Programming/Mixed Integer Programming framework for the preventive signaling maintenance crew scheduling problem
Cardiorespiratory and perceptual responses to self-regulated and imposed submaximal arm-leg ergometry
Purpose:
This study compared cardiorespiratory and perceptual responses to exercise using self-regulated and imposed power outputs distributed between the arms and legs.
Methods
Ten males (age 21.7 ± 3.4 years) initially undertook incremental arm-crank ergometry (ACE) and cycle ergometry (CYC) tests to volitional exhaustion to determine peak power output (Wpeak). Two subsequent tests involved 20-min combined arm–leg ergometry (ALE) trials, using imposed and self-regulated protocols, both of which aimed to elicit an exercising heart rate of 160 beats min−1. During the imposed trial, arm and leg intensity were set at 40% of each ergometer-specific Wpeak. During the self-regulated trial, participants were asked to self-regulate cadence and resistance to achieve the target heart rate. Heart rate (HR), oxygen uptake (V˙O2
), pulmonary ventilation (V˙E
), and ratings of perceived exertion (RPE) were recorded continuously.
Results
As expected, there were no differences between imposed and self-regulated trials for HR, V˙O2
, and V˙E
(all P ≥ 0.05). However, central RPE and local RPE for the arms were lower during self-regulated compared imposed trials (P ≤ 0.05). Lower RPE during the self-regulated trial was related to preferential adjustments in how the arms (33 ± 5% Wpeak) and legs (46 ± 5% Wpeak) contributed to the exercise intensity.
Conclusions:
This study demonstrates that despite similar metabolic and cardiovascular strain elicited by imposed and self-regulated ALE, the latter was perceived to be less strenuous, which is related to participants doing more work with the legs and less work with the arms to achieve the target intensity
Homeomorphic Embedding for Online Termination of Symbolic Methods
Well-quasi orders in general, and homeomorphic embedding in particular, have gained popularity to ensure the termination of techniques for program analysis, specialisation, transformation, and verification. In this paper we survey and discuss this use of homeomorphic embedding and clarify the advantages of such an approach over one using well-founded orders. We also discuss various extensions of the homeomorphic embedding relation. We conclude with a study of homeomorphic embedding in the context of metaprogramming, presenting some new (positive and negative) results and open problems
Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes
Aims/hypothesis This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA1c measurements are applicable to pregnant women with diabetes. Methods CGM data from 117 pregnant women (89 women with type 1 diabetes; 28 women with type 2 diabetes) were analysed. Average glucose levels were calculated from 5–7 day CGM profiles (mean 1275 glucose values per profile) and paired with a corresponding (±1 week) HbA1c measure. In total, 688 average glucose–HbA1c pairs were obtained across pregnancy (mean six pairs per participant). Average glucose level was used as the dependent variable in a regression model. Covariates were gestational week, study centre and HbA1c. Results There was a strong association between HbA1c and average glucose values in pregnancy (coefficient 0.67 [95% CI 0.57, 0.78]), i.e. a 1% (11 mmol/mol) difference in HbA1c corresponded to a 0.67 mmol/l difference in average glucose. The random effects model that included gestational week as a curvilinear (quadratic) covariate fitted best, allowing calculation of a pregnancy-specific eAG (PeAG). This showed that an HbA1c of 8.0% (64 mmol/mol) gave a PeAG of 7.4–7.7 mmol/l (depending on gestational week), compared with a standard eAG of 10.2 mmol/l. The PeAG associated with maintaining an HbA1c level of 6.0% (42 mmol/mol) during pregnancy was between 6.4 and 6.7 mmol/l, depending on gestational week. Conclusions/interpretation The HbA1c–average glucose relationship is altered by pregnancy. Routinely generated standard eAG values do not account for this difference between pregnant and non-pregnant individuals and, thus, should not be used during pregnancy. Instead, the PeAG values deduced in the current study are recommended for antenatal clinical care
Emerging technologies for the management of Type 1 diabetes in pregnancy
Purpose of Review: The purpose of the study is to discuss emerging technologies available in the management of type 1 diabetes in pregnancy. Recent Findings: The latest evidence suggests that continuous glucose monitoring (CGM) should be offered to all women on intensive insulin therapy in early pregnancy. Studies have additionally demonstrated the ability of CGM to help gain insight into specific glucose profiles as they relate to glycaemic targets and pregnancy outcomes. Despite new studies comparing insulin pump therapy to multiple daily injections, its effectiveness in improving glucose and pregnancy outcomes remains unclear. Sensor-integrated insulin delivery (also called artificial pancreas or closed-loop insulin delivery) in pregnancy has been demonstrated to improve time in target and performs well despite the changing insulin demands of pregnancy. Summary: Emerging technologies show promise in the management of type 1 diabetes in pregnancy; however, research must continue to keep up as technology advances. Further research is needed to clarify the role technology can play in optimising glucose control before and during pregnancy as well as to understand which women are candidates for sensor-integrated insulin delivery
Macrocyclic colibactin induces DNA double-strand breaks via copper-mediated oxidative cleavage.
Colibactin is an assumed human gut bacterial genotoxin, whose biosynthesis is linked to the clb genomic island that has a widespread distribution in pathogenic and commensal human enterobacteria. Colibactin-producing gut microbes promote colon tumour formation and enhance the progression of colorectal cancer via cellular senescence and death induced by DNA double-strand breaks (DSBs); however, the chemical basis that contributes to the pathogenesis at the molecular level has not been fully characterized. Here, we report the discovery of colibactin-645, a macrocyclic colibactin metabolite that recapitulates the previously assumed genotoxicity and cytotoxicity. Colibactin-645 shows strong DNA DSB activity in vitro and in human cell cultures via a unique copper-mediated oxidative mechanism. We also delineate a complete biosynthetic model for colibactin-645, which highlights a unique fate of the aminomalonate-building monomer in forming the C-terminal 5-hydroxy-4-oxazolecarboxylic acid moiety through the activities of both the polyketide synthase ClbO and the amidase ClbL. This work thus provides a molecular basis for colibactin's DNA DSB activity and facilitates further mechanistic study of colibactin-related colorectal cancer incidence and prevention
Application of real-time global media monitoring and ‘derived questions’ for enhancing communication by regulatory bodies:the case of human papillomavirus vaccines
Abstract Background The benefit-risk balance of vaccines is regularly debated by the public, but the utility of media monitoring for regulatory bodies is unclear. A media monitoring study was conducted at the European Medicines Agency (EMA) concerning human papillomavirus (HPV) vaccines during a European Union (EU) referral procedure assessing the potential causality of complex regional pain syndrome (CRPS) and postural orthostatic tachycardia syndrome (POTS) reported to the authorities as suspected adverse reactions. Methods To evaluate the utility of media monitoring in real life, prospective real-time monitoring of worldwide online news was conducted from September to December 2015 with inductive content analysis, generating ‘derived questions’. The evaluation was performed through the validation of the predictive capacity of these questions against journalists’ queries, review of the EMA’s public statement and feedback from EU regulators. Results A total of 4230 news items were identified, containing personal stories, scientific and policy/process-related topics. Explicit and implicit concerns were identified, including those raised due to lack of knowledge or anticipated once more information would be published. Fifty derived questions were generated and categorised into 12 themes. The evaluation demonstrated that providing the media monitoring findings to assessors and communicators resulted in (1) confirming that public concerns regarding CRPS and POTS would be covered by the assessment; (2) meeting specific information needs proactively in the public statement; (3) predicting all queries from journalists; and (4) altering the tone of the public statement with respectful acknowledgement of the health status of patients with CRSP or POTS. Conclusions The study demonstrated the potential utility of media monitoring for regulatory bodies to support communication proactivity and preparedness, intended to support trusted safe and effective vaccine use. Derived questions seem to be a familiar and effective format for presenting media monitoring results in the scientific-regulatory environment. It is suggested that media monitoring could form part of regular surveillance for medicines of high public interest. Future work is recommended to develop efficient monitoring strategies for that purpose
Application of real-time global media monitoring and ‘derived questions’ for enhancing communication by regulatory bodies:the case of human papillomavirus vaccines
Abstract Background The benefit-risk balance of vaccines is regularly debated by the public, but the utility of media monitoring for regulatory bodies is unclear. A media monitoring study was conducted at the European Medicines Agency (EMA) concerning human papillomavirus (HPV) vaccines during a European Union (EU) referral procedure assessing the potential causality of complex regional pain syndrome (CRPS) and postural orthostatic tachycardia syndrome (POTS) reported to the authorities as suspected adverse reactions. Methods To evaluate the utility of media monitoring in real life, prospective real-time monitoring of worldwide online news was conducted from September to December 2015 with inductive content analysis, generating ‘derived questions’. The evaluation was performed through the validation of the predictive capacity of these questions against journalists’ queries, review of the EMA’s public statement and feedback from EU regulators. Results A total of 4230 news items were identified, containing personal stories, scientific and policy/process-related topics. Explicit and implicit concerns were identified, including those raised due to lack of knowledge or anticipated once more information would be published. Fifty derived questions were generated and categorised into 12 themes. The evaluation demonstrated that providing the media monitoring findings to assessors and communicators resulted in (1) confirming that public concerns regarding CRPS and POTS would be covered by the assessment; (2) meeting specific information needs proactively in the public statement; (3) predicting all queries from journalists; and (4) altering the tone of the public statement with respectful acknowledgement of the health status of patients with CRSP or POTS. Conclusions The study demonstrated the potential utility of media monitoring for regulatory bodies to support communication proactivity and preparedness, intended to support trusted safe and effective vaccine use. Derived questions seem to be a familiar and effective format for presenting media monitoring results in the scientific-regulatory environment. It is suggested that media monitoring could form part of regular surveillance for medicines of high public interest. Future work is recommended to develop efficient monitoring strategies for that purpose
Paraspinal muscle cross-sectional area predicts low back disability but not pain intensity
BACKGROUND AND CONTEXT: The lumbar paraspinal muscles, including the erector spinae and multifidus, play an important role in movement and control of the spine. However, our understanding of their contribution to low back pain and disability is unclear. Systematic reviews have reported conflicting evidence for an association between paraspinal muscle size and low back pain, and a paucity of data examining muscle cross-sectional area (CSA) and low back disability.PURPOSE: To investigate the relationship between paraspinal muscle CSA and both low back pain intensity and disability.STUDY DESIGN/SETTING: One-year longitudinal cohort study.PATIENT SAMPLE: Participants were selected from the SpineData Registry (Denmark), which enrolls people with low back pain of 2 to 12 months duration without radiculopathy and a satisfactory response to primary intervention.OUTCOME MEASURES: Current, typical, and worst pain in the prior 2 weeks were assessed by 11-point numeric rating scales and an average pain score was calculated, and disability was measured using the 23-item Roland-Morris Disability Questionnaire. CSA (cm 2) of the lumbar paraspinal muscles was measured at levels L3-L5 from magnetic resonance images. METHODS: Participants completed the study questionnaires and underwent the lumbar spine magnetic resonance images at baseline and were followed up 12 months later to repeat the questionnaires. Statistical analyses involved multivariable linear regression (cross-sectional analysis) and linear mixed-models (longitudinal analysis) with adjustment for confounders. Multiple imputation was conducted to account for missing data.RESULTS: A total of 962 participants were included and 588 (65.8%) were followed up at 12-months. Multivariable analysis showed that greater paraspinal muscle CSA was associated with lower levels of disability, after adjusting for confounders (right mean CSA: baseline beta -0.16, 95% CI -0.26 to -0.06, p<.01; longitudinal beta -0.11, 95% CI -0.21 to -0.01, p=.03). This was evident at all levels, except L5 which was marginal at baseline (beta -0.08, 95% CI -0.15 to -0.001, p=.045) and not significant longitudinally (beta -0.05, 95% CI -0.12 to 0.02, p=.18). However, there were no associations between muscle CSA and pain intensity (baseline beta -0.02, 95% CI -0.06 to 0.02, p=.29; longitudinal beta -0.02, 95% CI -0.06 to 0.02, p=.34). Results were similar for both complete case and multiple imputation analyses.CONCLUSIONS: This study found an inverse relationship between lumbar paraspinal muscle CSA and low back disability, but not pain intensity. While further investigation is needed, these findings suggest that treatment strategies directed at increasing paraspinal muscle size may be effective in reducing low back disability.</p
- …
