    Vanishing tilt-to-length coupling for a singular case in two-beam laser interferometers with Gaussian beams

    Get PDF
    The omnipresent tilt-to-length coupling in two-beam laser interferometers, frequently a nuisance in precision measurements, vanishes for the singular case of two beams with identical parameters and complete detection of both beams without clipping. This effect has been observed numerically and is explained in this manuscript by the cancellation of two very different effects of equal magnitude and opposite sign. This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: [http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-54-5-1010]. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law

    A brief comparison of optical pathlength difference and various definitions for the interferometric phase

    Get PDF
    To this paper we discuss that the phase readout in low noise laser interferometers can significantly deviate from the underlying optical pathlength difference (OPD). The cross coupling of beam tilt to the interferometric phase readout is compared to the OPD. For such a system it is shown that the amount of tilt to phase readout coupling depends strongly on the involved beams and their parameters, as well as on the detector properties and the precise definition of the phase. The unique single element photodiode phase is therefore compared to three common phase definitions for quadrant diodes. It is shown that neither phase definition globally shows the least amount of cross coupling of angular itDeutsches Zentrum für Luft- und Raumfahrt (DLR)/No 50 OQ 130

    Nocturnal nitrogen oxides at a rural mountain-site in south-western Germany

    Get PDF
    A new, two-channel instrument for simultaneous NO3 and N2O5 monitoring was used to make the first comprehensive set of nocturnal NOx measurements (NO, NO2, NO3 and N2O5) at the Taunus Observatory, a rural mountain site (Kleiner Feldberg) in South-western Germany. In May 2008, NO3 and N2O5 mixing ratios were well above the instrumental detection limit (a few ppt) on all nights of the campaign and were characterised by large variability. The concentrations of NO3, N2O5 and NO2 were consistent with the equilibrium constant, K2, defining the rates of formation and thermal dissociation of N2O5. A steady-state lifetime analysis is consistent with the loss of nocturnal NOx being dominated by the reaction of NO3 with volatile organic compounds in this forested region, with N2O5 uptake to aerosols of secondary importance. Analysis of a limited dataset obtained at high relative humidity indicated that the loss of N2O5 by reaction with water vapour is less efficient (>factor 3) than derived using laboratory kinetic data. The fraction of NOx present as NO3 and N2O5 reached ~20% on some nights, with night-time losses of NOx competing with daytime losses

    Efficiency Improvement of a Constant Pressure System using an Intermediate Pressure Line

    Get PDF
    The paper introduces a new hydraulic system based on a constant pressure system with the aim to increase the efficiency of actuation of hydraulic cylinders in mobile machines. Using a third pressure level located between high pressure and tank pressure called intermediate pressure the system enables additional pressure potentials from high pressure to intermediate pressure and from intermediate pressure to tank pressure. This reduces throttle losses at hydraulic cylinders when driven at low or medium loads. An accumulator connected to the intermediate pressure line is being charged or discharged in function of which pressure potential is currently used. Using the example of a typical duty cycle of a wheel loader the paper describes how the accumulator can be applied in order to reach best efficiency results for the new system and it reveals a theoretical efficiency improvement of 20% compared to a conventional Load Sensing system. Furthermore it proposes an online control strategy using Model Predictive Control with an optimization algorithm created with the Dynamic Programming method

    Die Bedeutung der Kommunikation im Alltag von Hör- und Sehbeeinträchtigten

    Get PDF

    Sub-system mechanical design for an eLISA optical bench

    Get PDF
    We present the design and development status of the opto-mechanical sub-systems that will be used in an experimental demonstration of imaging systems for eLISA. An optical bench test bed design incorporates a Zerodur® baseplate with lenses, photodetectors, and other opto-mechanics that must be both adjustable - with an accuracy of a few micrometers - and stable over a 0 to 40°C temperature range. The alignment of a multi-lens imaging system and the characterisation of the system in multiple degrees of freedom is particularly challenging. We describe the mechanical design of the precision mechanisms, including thermally stable flexure-based optical mounts and complex multi-lens, multi-axis adjuster mechanisms, and update on the integration of the mechanisms on the optical bench

    Full length interleukin 33 aggravates radiation-induced skin reaction

    Get PDF
    The interleukin (IL)-1 family member IL-33 has been described as intracellular alarmin with broad roles in wound healing, skin inflammation but also autoimmunity. Its dichotomy between full length (fl) IL-33 and the mature (m) form of IL-33 and its release by necrosis is still not fully understood. Here, we compare functional consequences of both forms in the skin in vivo, and therefore generated two lines of transgenic mice which selectively overexpress mmIL-33 and flmIL-33 in basal keratinocytes. Transgene mRNA was expressed at high level in skin of both lines but not in organs due to the specific K14 promoter. We could demonstrate that transgenic overexpression of mmIL-33 in murine keratinocytes leads to a spontaneous skin inflammation as opposed to flmIL-33. K14-mmIL-33 mice synthesize and secrete high amounts of mmIL-33 along with massive cutaneous manifestations, like increased epidermis and dermis thickness, infiltration of mast cells in the epidermis and dermis layers and marked hyperkeratosis. Using skin inflammation models such as IL-23 administration, imiquimod treatment, or mechanical irritation did not lead to exacerbated inflammation in the K14-flmIL-33 strain. As radiation induces a strong dermatitis due to apoptosis and necrosis, we determined the effect of fractionated radiation (12 Gy, 4 times). In comparison to wild-type mice, an increase in ear thickness in flmIL-33 transgenic mice was observed 25 days after irradiation. Macroscopic examination showed more severe skin symptoms in irradiated ears compared to controls. In summary, secreted mmIL-33 itself has a potent capacity in skin inflammation whereas fl IL-33 is limited due to its intracellular retention. During tissue damage, fl IL-33 exacerbated radiation-induced skin reaction

    A two-channel, Thermal Dissociation Cavity-Ringdown Spectrometer for the detection of ambient NO2, RO2NO2 and RONO2

    Get PDF
    Creative Commons Attribution License 3.0We describe a thermal dissociation cavity ring-down spectrometer (TD-CRDS) for measurement of ambient NO2, total peroxy nitrates (ΣPNs) and total alkyl nitrates (ΣANs). The spectrometer has two separate cavities operating at  ∼  405.2 and 408.5 nm. One cavity (reference) samples NO2 continuously from an inlet at ambient temperature, the other samples sequentially from an inlet at 473 K in which PNs are converted to NO2 or from an inlet at 723 K in which both PNs and ANs are converted to NO2, difference signals being used to derive mixing ratios of ΣPNs and ΣANs. We describe an extensive set of laboratory experiments and numerical simulations to characterise the fate of organic radicals in the hot inlets and cavity and derive correction factors to account for the bias resulting from the interaction of peroxy radicals with ambient NO and NO2. Finally, we present the first measurements and comparison with other instruments during a field campaign, outline the limitations of the present instrument and provide an outlook for future improvements.Publication funded by the Max Planck Societ

    Testing for the MMX Rover Autonomous Navigation Experiment on Phobos

    Get PDF
    The MMX rover will explore the surface of Phobos, Mars´ bigger moon. It will use its stereo cameras for perceiving the environment, enabling the use of vision based autonomous navigation algorithms. The German Aerospace Center (DLR) is currently developing the corresponding autonomous navigation experiment that will allow the rover to efficiently explore the surface of Phobos, despite limited communication with Earth and long turn-around times for operations. This paper discusses our testing strategy regarding the autonomous navigation solution. We present our general testing strategy for the software considering a development approach with agile aspects. We detail, how we ensure successful integration with the rover system despite having limited access to the flight hardware. We furthermore discuss, what environmental conditions on Phobos pose a potential risk for the navigation algorithms and how we test for these accordingly. Our testing is mostly data set-based and we describe our approaches for recording navigation data that is representative both for the rover system and also for the Phobos environment. Finally, we make the corresponding data set publicly available and provide an overview on its content