111 research outputs found
Risk stratification in mild and moderate aortic stenosis by assessment of aortic valve calcification
Lack of uniform diagnostic criteria for cervical radiculopathy in conservative intervention studies: A systematic review
Purpose: Cervical radiculopathy (CR) is a common diagnosis. It is unclear if intervention studies use uniform definitions and criteria for patient selection. Our objective was to assess the uniformity of diagnostic criteria and definitions used in intervention studies to select patients with CR. Methods: We electronically searched the Cochrane Controlled Trials Register, MEDLINE, EMBASE and CINAHL. Studies were included when evaluating conservative interventions in randomised clinical trials (RCTs) in patients with CR. Selection criteria and definitions for patients with CR were extracted and evaluated on their uniformity. Results: Thirteen RCTs were included. Pain was used as an inclusion criterion in 11 studies. Inclusion based on the duration and location of pain varied between studies. Five studies used sensory symptoms in the arm as inclusion crite
The Behavioral and Psychological Symptoms of Dementia in Down Syndrome (BPSD-DS) Scale:Comprehensive Assessment of Psychopathology in Down Syndrome
People with Down syndrome (DS) are prone to develop Alzheimer's disease (AD). Behavioral and psychological symptoms of dementia (BPSD) are core features, but have not been comprehensively evaluated in DS. In a European multidisciplinary study, the novel Behavioral and Psychological Symptoms of Dementia in Down Syndrome (BPSD-DS) scale was developed to identify frequency and severity of behavioral changes taking account of life-long characteristic behavior. 83 behavioral items in 12 clinically defined sections were evaluated. The central aim was to identify items that change in relation to the dementia status, and thus may differentiate between diagnostic groups. Structured interviews were conducted with informants of persons with DS without dementia (DS, n = 149), with questionable dementia (DS+Q, n = 65), and with diagnosed dementia (DS+AD, n = 67). First exploratory data suggest promising interrater, test-retest, and internal consistency reliability measures. Concerning item relevance, group comparisons revealed pronounced increases in frequency and severity in items of anxiety, sleep disturbances, agitation & stereotypical behavior, aggression, apathy, depressive symptoms, and eating/drinking behavior. The proportion of individuals presenting an increase was highest in DS+AD, intermediate in DS+Q, and lowest in DS. Interestingly, among DS+Q individuals, a substantial proportion already presented increased anxiety, sleep disturbances, apathy, and depressive symptoms, suggesting that these changes occur early in the course of AD. Future efforts should optimize the scale based on current results and clinical experiences, and further study applicability, reliability, and validity. Future application of the scale in daily care may aid caregivers to understand changes, and contribute to timely interventions and adaptation of caregiving
Measurement of the cosmic ray spectrum above eV using inclined events detected with the Pierre Auger Observatory
A measurement of the cosmic-ray spectrum for energies exceeding
eV is presented, which is based on the analysis of showers
with zenith angles greater than detected with the Pierre Auger
Observatory between 1 January 2004 and 31 December 2013. The measured spectrum
confirms a flux suppression at the highest energies. Above
eV, the "ankle", the flux can be described by a power law with
index followed by
a smooth suppression region. For the energy () at which the
spectral flux has fallen to one-half of its extrapolated value in the absence
of suppression, we find
eV.Comment: Replaced with published version. Added journal reference and DO
Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory
The Auger Engineering Radio Array (AERA) is part of the Pierre Auger
Observatory and is used to detect the radio emission of cosmic-ray air showers.
These observations are compared to the data of the surface detector stations of
the Observatory, which provide well-calibrated information on the cosmic-ray
energies and arrival directions. The response of the radio stations in the 30
to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of
the incoming electric field. For the latter, the energy deposit per area is
determined from the radio pulses at each observer position and is interpolated
using a two-dimensional function that takes into account signal asymmetries due
to interference between the geomagnetic and charge-excess emission components.
The spatial integral over the signal distribution gives a direct measurement of
the energy transferred from the primary cosmic ray into radio emission in the
AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air
shower arriving perpendicularly to the geomagnetic field. This radiation energy
-- corrected for geometrical effects -- is used as a cosmic-ray energy
estimator. Performing an absolute energy calibration against the
surface-detector information, we observe that this radio-energy estimator
scales quadratically with the cosmic-ray energy as expected for coherent
emission. We find an energy resolution of the radio reconstruction of 22% for
the data set and 17% for a high-quality subset containing only events with at
least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO
Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy
We measure the energy emitted by extensive air showers in the form of radio
emission in the frequency range from 30 to 80 MHz. Exploiting the accurate
energy scale of the Pierre Auger Observatory, we obtain a radiation energy of
15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV
arriving perpendicularly to a geomagnetic field of 0.24 G, scaling
quadratically with the cosmic-ray energy. A comparison with predictions from
state-of-the-art first-principle calculations shows agreement with our
measurement. The radiation energy provides direct access to the calorimetric
energy in the electromagnetic cascade of extensive air showers. Comparison with
our result thus allows the direct calibration of any cosmic-ray radio detector
against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI.
Supplemental material in the ancillary file
The behavioral and psychological symptoms of dementia in down syndrome (BPSD-DS) scale:comprehensive assessment of psychopathology in down syndrome
Behavioral and psychological symptoms of dementia (BPSD) have not been comprehensively studied in people with Down syndrome, despite their high risk on dementia. A novel evaluation scale was developed to identify the nature, frequency and severity of behavioral changes (83 behavioral items in 12 clinically defined sections). Central aim was to identify items that change in relation to the dementia status. Structured interviews were conducted with informants of people with Down syndrome without dementia (DS, NâŻ=â149), with questionable dementia (DSâŻ+âTD, NâŻ=â65) and with diagnosed dementia (DSâŻ+âAD, NâŻ=â67). Group comparisons showed a pronounced increase in frequency and severity of items about anxiety, sleep disturbances, agitation & stereotypical behavior, aggression, apathy, depressive symptoms, and, eating/drinking behavior. The proportion of individuals presenting an increase was highest in the DSâŻ+âAD group and lowest in the DS group. Interestingly, among DSâŻ+âTD individuals, a substantial proportion already presented increased anxiety, sleep disturbances, apathy and depressive symptoms, suggesting that these changes may be early alarm signals of dementia. The scale may contribute to a better understanding of the changes, adapting daily care/support, and providing suitable therapies to people with Down syndrome. The scale needs to be optimized based on the results and experiences. The applicability, reliability and validity require further study
An upper limit to the photon fraction in cosmic rays above 10^19 eV from the Pierre Auger Observatory
An upper limit of 16% (at 95% c.l.) is derived for the photon fraction in cosmic rays with energies above 10^19 eV, based on observations of the depth of shower maximum performed with the hybrid detector of the Pierre Auger Observatory. This is the first such limit on photons obtained by observing the fluorescence light profile of air showers. This upper limit confirms and improves on previous results from the Haverah Park and AGASA surface arrays. Additional data recorded with the Auger surface detectors for a subset of the event sample, support the conclusion that a photon origin of the observed events is not favoured
- âŠ