92 research outputs found

    Spin polarization of the L-gap surface states on Au(111)

    Full text link
    The electron spin polarization (ESP) of the L-gap surface states on Au(111) is investigated theoretically by means of first-principles electronic-structure and photoemission calculations. The surface states show a large spin-orbit induced in-plane ESP which is perpendicular to the in-plane wavevector, in close analogy to a two-dimensional electron gas with Rashba spin-orbit interaction. The surface corrugation leads to a small ESP component normal to the surface, being not reported so far. The surface-states ESP can be probed qualitatively and quantitatively by spin- and angle-resolved photoelectron spectroscopy, provided that the initial-state ESP is retained in the photoemission process and not obscured by spin-orbit induced polarization effects. Relativistic photoemission calculations provide detailed information on what photoemission set-ups allow to conclude from the photoelectron ESP on that of the surface states.Comment: 22 pages with 8 figure

    Final State Interaction Effects in pol 3He(pol e,e'p)

    Get PDF
    Asymmetries in quasi-elastic pol 3He(pol e,e'p) have been measured at a momentum transfer of 0.67 (GeV/c)^2 and are compared to a calculation which takes into account relativistic kinematics in the final state and a relativistic one-body current operator. With an exact solution of the Faddeev equation for the 3He-ground state and an approximate treatment of final state interactions in the continuum good agreement is found with the experimental data.Comment: 11 pages, 6 figures, submitted to Phys. Lett. B, revised version, sensitivity study to relativity and NN-potential adde

    Measurement of the asymmetries in 3He→ \overrightarrow{\sf He}(ÂŻe, eâ€Čp)d and 3He→ \overrightarrow{\sf He}(ÂŻe, eâ€Čp)np

    Get PDF
    Abstract.: The electron target asymmetries A || and A⊄ with target spin parallel and perpendicular to the momentum transfer \ensuremath{\boldsymbol{q}} were measured for both the two- and three-body breakup of 3He in the 3 He→ \overrightarrow{\rm He} (ÂŻe, e'p)-reaction. Polarized electrons were scattered off polarized 3He in the quasielastic regime in parallel kinematics with the scattered electron and the knocked-out proton detected using the Three-Spectrometer Facility at MAMI. The results are compared to Faddeev calculations which take into account Final-State Interactions as well as Meson Exchange Currents. The experiment confirms the prediction of a large effect of Final-State Interactions in the asymmetry of the three-body breakup and of an almost negligible one for the two-body breaku

    Oxygen-sensitive 3He-MRI in bronchiolitis obliterans after lung transplantation

    Get PDF
    Oxygen-sensitive 3He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO2) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acqiured on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n = 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (−1.75 mbar/s versus −0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients

    Improved Leakage Correction for Single-Echo Dynamic Susceptibility Contrast Perfusion MRI Estimates of Relative Cerebral Blood Volume in High-Grade Gliomas by Accounting for Bidirectional Contrast Agent Exchange

    Full text link
    Background and purposeContrast agent extravasation through a disrupted blood-brain barrier potentiates inaccurate DSC MR imaging estimation of relative CBV. We explored whether incorporation of an interstitial washout rate in a leakage-correction model for single-echo, gradient-echo DSC MR imaging improves relative CBV estimates in high-grade gliomas.Materials and methodsWe modified the traditional model-based postprocessing leakage-correction algorithm, assuming unidirectional contrast agent extravasation (Boxerman-Weisskoff model) to account for bidirectional contrast agent exchange between intra- and extravascular spaces (bidirectional model). For both models, we compared the goodness of fit with the parent leakage-contaminated relaxation rate curves by using the Akaike Information Criterion and the difference between modeled interstitial relaxation rate curves and dynamic contrast-enhanced MR imaging by using Euclidean distance in 21 patients with glioblastoma multiforme.ResultsThe bidirectional model had improved Akaike Information Criterion versus the bidirectional model in >50% of enhancing tumor voxels in all 21 glioblastoma multiformes (77% ± 9%; P < .0001) and had reduced the Euclidean distance in >50% of enhancing tumor voxels for 17/21 glioblastoma multiformes (62% ± 17%; P = .0041). The bidirectional model and dynamic contrast-enhanced-derived kep demonstrated a strong correlation (r = 0.74 ± 0.13). On average, enhancing tumor relative CBV for the Boxerman-Weisskoff model exceeded that for the bidirectional model by 16.6% ± 14.0%.ConclusionsInclusion of the bidirectional exchange in leakage-correction models for single-echo DSC MR imaging improves the model fit to leakage-contaminated DSC MR imaging data and significantly improves the estimation of relative CBV in high-grade gliomas

    A causal account of the brain network computations underlying strategic social behavior

    Get PDF
    During competitive interactions, humans have to estimate the impact of their own actions on their opponent's strategy. Here we provide evidence that neural computations in the right temporoparietal junction (rTPJ) and interconnected structures are causally involved in this process. By combining inhibitory continuous theta-burst transcranial magnetic stimulation with model-based functional MRI, we show that disrupting neural excitability in the rTPJ reduces behavioral and neural indices of mentalizing-related computations, as well as functional connectivity of the rTPJ with ventral and dorsal parts of the medial prefrontal cortex. These results provide a causal demonstration that neural computations instantiated in the rTPJ are neurobiological prerequisites for the ability to integrate opponent beliefs into strategic choice, through system-level interaction within the valuation and mentalizing networks

    Enhancement of the reflectivity of Mo/Si multilayer x-ray mirrors by thermal treatment

    Get PDF
    Kloidt A, Nolting K, Kleineberg U, et al. Enhancement of the reflectivity of Mo/Si multilayer x-ray mirrors by thermal treatment. Applied Physics Letters. 1991;58(23):2601-2603.Thermal treatment of a Mo/Si multilayer stack enhances its reflectivity in the soft x-ray region. The multilayer x-ray mirrors are fabricated by electron beam evaporation in ultrahigh vacuum. In situ measurement of the reflectivity during the deposition allows thickness control and an observation of changes in quality of the boundaries. By heating the substrates during deposition we obtain a smoothing of the interfaces. This leads to x-ray mirrors with peak reflectivity around 50% for normal incident radiation of wavelengths between 130 and 140 A
    • 

    corecore