747 research outputs found

    Characterizing Exoplanets in the Visible and Infrared: A Spectrometer Concept for the EChO Space Mission

    Get PDF
    Transit-spectroscopy of exoplanets is one of the key observational techniques to characterize the extrasolar planet and its atmosphere. The observational challenges of these measurements require dedicated instrumentation and only the space environment allows an undisturbed access to earth-like atmospheric features such as water or carbon-dioxide. Therefore, several exoplanet-specific space missions are currently being studied. One of them is EChO, the Exoplanet Characterization Observatory, which is part of ESA's Cosmic Vision 2015-2025 program, and which is one of four candidates for the M3 launch slot in 2024. In this paper we present the results of our assessment study of the EChO spectrometer, the only science instrument onboard this spacecraft. The instrument is a multi-channel all-reflective dispersive spectrometer, covering the wavelength range from 400 nm to 16 microns simultaneously with a moderately low spectral resolution. We illustrate how the key technical challenge of the EChO mission - the high photometric stability - influences the choice of spectrometer concept and drives fundamentally the instrument design. First performance evaluations underline the fitness of the elaborated design solution for the needs of the EChO mission.Comment: 20 pages, 8 figures, accepted for publication in the Journal of Astronomical Instrumentatio

    Survival benefit of chemotherapy in metastatic colorectal cancer: a meta-analysis of randomized controlled trials

    Get PDF
    To estimate the magnitude of benefit of chemotherapy in prolonging survival for patients with metastatic colorectal cancer, a meta-analysis of randomized controlled trial was performed. A systematic search was performed to identify randomized trials comparing chemotherapy with observation or supportive care alone. Trials were assessed for quality of reporting, publication bias and heterogeneity. Relative risks for outcomes from published data were pooled using a random-effects model. Seven trials with 614 patients were included. All trials used fluoropyrimidine-based chemotherapy, through a variety of routes and schedules, including intravenous, intra-portal and hepatic arterial infusion. Compared with the ‘no-chemotherapy’ arm, chemotherapy significantly reduced 1-year mortality (risk ratio 0.69; 95% confidence interval (CI) 0.60–0.81, P< 0.00001). The mortality at 2 years was not significantly different (risk ratio 0.93; 95% CI 0.87–1.00, P = 0.053). Between-trial comparisons demonstrated benefit with a variety of routes and schedules. Chemotherapy significantly prolongs 1-year survival for patients with metastatic colorectal cancer, and should be offered to those with good performance status. © 2000 Cancer Research Campaig

    Hand disinfection in a neonatal intensive care unit: continuous electronic monitoring over a one-year period

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Good hand hygiene compliance is essential to prevent nosocomial infections in healthcare settings. Direct observation of hand hygiene compliance is the gold standard but is time consuming. An electronic dispenser with built-in wireless recording equipment allows continuous monitoring of its usage. The purpose of this study was to monitor the use of alcohol-based hand rub dispensers with a built-in electronic counter in a neonatal intensive care unit (NICU) setting and to determine compliance with hand hygiene protocols by direct observation.</p> <p>Methods</p> <p>A one-year observational study was conducted at a 27 bed level III NICU at a university hospital. All healthcare workers employed at the NICU participated in the study. The use of bedside dispensers was continuously monitored and compliance with hand hygiene was determined by random direct observations.</p> <p>Results</p> <p>A total of 258,436 hand disinfection events were recorded; i.e. a median (interquartile range) of 697 (559–840) per day. The median (interquartile range) number of hand disinfection events performed per healthcare worker during the day, evening, and night shifts was 13.5 (10.8 - 16.7), 19.8 (16.3 - 24.1), and 16.6 (14.2 - 19.3), respectively. In 65.8% of the 1,168 observations of patient contacts requiring hand hygiene, healthcare workers fully complied with the protocol.</p> <p>Conclusions</p> <p>We conclude that the electronic devices provide useful information on frequency, time, and location of its use, and also reveal trends in hand disinfection events over time. Direct observations offer essential data on compliance with the hand hygiene protocol. In future research, data generated by the electronic devices can be supplementary used to evaluate the effectiveness of hand hygiene promotion campaigns.</p

    Evaluating predictive pharmacogenetic signatures of adverse events in colorectal cancer patients treated with fluoropyrimidines

    Get PDF
    The potential clinical utility of genetic markers associated with response to fluoropyrimidine treatment in colorectal cancer patients remains controversial despite extensive study. Our aim was to test the clinical validity of both novel and previously identified markers of adverse events in a broad clinical setting. We have conducted an observational pharmacogenetic study of early adverse events in a cohort study of 254 colorectal cancer patients treated with 5-fluorouracil or capecitabine. Sixteen variants of nine key folate (pharmacodynamic) and drug metabolising (pharmacokinetic) enzymes have been analysed as individual markers and/or signatures of markers. We found a significant association between TYMP S471L (rs11479) and early dose modifications and/or severe adverse events (adjusted OR = 2.02 [1.03; 4.00], p = 0.042, adjusted OR = 2.70 [1.23; 5.92], p = 0.01 respectively). There was also a significant association between these phenotypes and a signature of DPYD mutations (Adjusted OR = 3.96 [1.17; 13.33], p = 0.03, adjusted OR = 6.76 [1.99; 22.96], p = 0.002 respectively). We did not identify any significant associations between the individual candidate pharmacodynamic markers and toxicity. If a predictive test for early adverse events analysed the TYMP and DPYD variants as a signature, the sensitivity would be 45.5 %, with a positive predictive value of just 33.9 % and thus poor clinical validity. Most studies to date have been under-powered to consider multiple pharmacokinetic and pharmacodynamic variants simultaneously but this and similar individualised data sets could be pooled in meta-analyses to resolve uncertainties about the potential clinical utility of these markers

    A Bayesian re-assessment of two Phase II trials of gemcitabine in metastatic nasopharyngeal cancer

    Get PDF
    The Simon two-stage minimax design is a popular statistical design used in Phase II clinical trials. The analysis of the data arising from the design typically involves the use of frequentist statistics. This paper presents an alternative, Bayesian, approach to the design and analysis of Phase II clinical trials. In particular, we consider how a Bayesian approach could have affected the design, analysis and interpretation of two parallel Phase II trials of the National Cancer Centre Singapore, on the activity of gemcitabine in chemotherapy-naĂŻve and in previously treated patients with metastatic nasopharyngeal carcinoma. We begin by explaining the Bayesian methodology and contrasting it with the frequentist approach. We then carry out a Bayesian analysis of the trial results. The conclusions drawn using the Bayesian approach were in general agreement with those obtained from the frequentist analysis. However they had the advantage of allowing for different and potentially more useful interpretations to be made regarding the trial results, as well as for the incorporation of external sources of information. In particular, using a Bayesian trial design, we were able to take into account the results of the parallel trial results when deciding whether to continue each trial beyond the interim stage
    • 

    corecore