8 research outputs found

    Quantitative analysis of dynamic computed tomography angiography for the detection of endoleaks after abdominal aorta aneurysm endovascular repair:A feasibility study

    Get PDF
    ObjectivesTo assess the feasibility of quantitative analysis of dynamic computed tomography angiography (dCTA) for the detection of endoleaks in patients who underwent endovascular repair of abdominal aortic aneurysms (EVAR).Material and methodsTwenty patients scheduled for contrast-enhanced CT angiography (CTA) of the abdominal aorta post-EVAR were prospectively enrolled. All patients received a standard triphasic CTA protocol, followed by an additional dCTA. The dCTA acquisition enabled reconstruction of color-coded maps depicting blood perfusion and a dCTA dataset of the aneurysm sac. Observers assessed the dCTA and dynamic CT perfusion (dCTP) images for the detection of endoleaks, establishing diagnostic confidence based on a modified 5-point Likert scale. An index was calculated for the ratio between the endoleak and aneurysm sac using blood flow for dCTP and Hounsfield units (HU) for dCTA. The Wilcoxon test compared the endoleak index and the diagnostic confidence of the observers.ResultsIn total, 19 patients (18 males, median age 74 years [70.5-75.7]) were included for analysis. Nine endoleaks were detected in 7 patients using triphasic CTA as the reference standard. There was complete agreement for endoleak detection between the two techniques on a per-patient basis. Both dCTA and dCTP identified an additional endoleak in one patient. The diagnostic confidence using dCTP for detection of endoleaks was not significantly superior to dCTA (5.0 [5-5] vs. 4.5 [4-5], respectively; p = 0.11); however, dCTP demonstrated superior diagnostic confidence for endoleak exclusion compared to dCTA (1.0 [1-1] vs 1.5 [1.5-1.5], respectively; p ConclusionsQuantitative analysis of dCTP imaging can aid in the detection of endoleaks and demonstrates a higher endoleak detection rate than triphasic CTA, as well as a strong correlation with visual assessment of dCTA images

    Predictive Value of Cardiac CTA, Cardiac MRI, and Transthoracic Echocardiography for Cardioembolic Stroke Recurrence

    Get PDF
    Background: Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. While TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. Objectives: To investigate sensitivity, specificity and predictive value of cardiac CT angigography (cCTA), cardiac MRI (CMR), and TTE for recurrence in patients with suspected cardioembolic stroke. Methods: We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMR (n=75) or cCTA (n=76) between January 2013 and May 2017. We evaluated for presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end-point was stroke recurrence. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for recurrent stroke were calculated; the diagnostic accuracy of CMR, cCTA, and TTE was compared between and within groups using area under the curves (AUCs). Results: Twelve and 14 recurrent strokes occurred in the cCTA and CMR groups, respectively. Sensitivity, specificity, PPV and NPV were: 33.3%, 93.7%, 50.0%, and 88.2% for cCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMR; 14.3%, 83.6%, 16.7%, 80.9% for TTE in the CMR group, and 8.3%, 93.7%, 20.0% and 84.5% for TTE in the cCTA group. Accuracy was not different (p>0.05) between cCTA (0.63, 95% CI [0.49, 0.77]), CMR (0.53, [0.42, 0.63]), TTE in CMR group (0.51, [0.40, 0.61], and TTE in cCTA group (0.51, [0.42, 0.59]). In cCTA group, atrial and ventricular thrombus were detected by cCTA in 3 patients and TTE in 1 patient; in CMR group, thrombus was detected by CMR in 1 patient and TTE in 2 patients. Conclusion: cCTA, CMR, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. cCTA and CMR may be valid alternatives to TTE. cCTA may be preferred given potentially better detection of atrial and ventricular thrombus. Clinical impact: cCTA and CMR have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings

    Fully automated contour detection of the ascending aorta in cardiac 2D phase-contrast MRI

    Get PDF
    Purpose In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). Material and methods Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI examination, performed from September 2008 to October 2013, was unremarkable. The local Ethical Committee approved this retrospective study. The ascending aorta was automatically identified on each phase of the cardiac cycle using a priori knowledge of aortic geometry. The frame that maximized the area, eccentricity, and solidity parameters was chosen for unsupervised initialization. Aortic segmentation was performed on each frame using active contouring without edges techniques. The entire algorithm was developed using Matlab R2016b. To validate the proposed method, the manual segmentation performed by a highly experienced operator was used. Dice similarity coefficient, Bland-Altman analysis, and Pearson's correlation coefficient were used as performance metrics. Results Comparing automated and manual segmentation of the aortic lumen on 714 images, Bland-Altman analysis showed a bias of â\u88\u92 6.68 mm2, a coefficient of repeatability of 91.22 mm2, a mean area measurement of 581.40 mm2, and a reproducibility of 85%. Automated and manual segmentation were highly correlated (R = 0.98). The Dice similarity coefficient versus the manual reference standard was 94.6 ± 2.1% (mean ± standard deviation). Conclusion A fully automated and robust method for identification and segmentation of ascending aorta on PC-MRI was developed. Its application on patients with a variety of pathologic conditions is advisable

    Harmonic balance method to analyze bifurcations in memristor oscillatory circuits

    No full text
    The paper studies nonlinear dynamics and bifurcations of a class of memristor oscillatory circuits obtained by replacing the nonlinear resistor of a Chua's oscillator with a flux-controlled memristor. A recently developed technique, named flux-charge analysis method, has shown that the state space of such circuits can be decomposed in invariant manifolds, where each manifold is characterized by a different dynamics and different attractors. Goal of the paper is to investigate the use of the harmonic balance method in combination with flux-charge analysis method in order to study the different kinds of bifurcations generated by changing the circuit parameters on a fixed manifold, changing manifold for a fixed parameter set (bifurcations without parameters), or changing simultaneously circuit parameters and manifolds. The main result is that the harmonic balance method is quite simple to apply in this rich bifurcation context and is effective to detect Hopf and to accurately predict period-doubling bifurcations of all these different kinds. Copyright © 2017 John Wiley & Sons, Ltd

    Monitoring microseismicity of the Hengill Geothermal Field in Iceland.

    Get PDF
    Induced seismicity is one of the main factors that reduces societal acceptance of deep geothermal energy exploitation activities, and felt earthquakes are the main reason for closure of geothermal projects. Implementing innovative tools for real-time monitoring and forecasting of induced seismicity was one of the aims of the recently completed COSEISMIQ project. Within this project, a temporary seismic network was deployed in the Hengill geothermal region in Iceland, the location of the nation's two largest geothermal power plants. In this paper, we release raw continuous seismic waveforms and seismicity catalogues collected and prepared during this project. This dataset is particularly valuable since a very dense network was deployed in a seismically active region where thousand of earthquakes occur every year. For this reason, the collected dataset can be used across a broad range of research topics in seismology ranging from the development and testing of new data analysis methods to induced seismicity and seismotectonics studies

    Monitoring microseismicity of the Hengill Geothermal Field in Iceland

    No full text
    Induced seismicity is one of the main factors that reduces societal acceptance of deep geothermal energy exploitation activities, and felt earthquakes are the main reason for closure of geothermal projects. Implementing innovative tools for real-time monitoring and forecasting of induced seismicity was one of the aims of the recently completed COSEISMIQ project. Within this project, a temporary seismic network was deployed in the Hengill geothermal region in Iceland, the location of the nation's two largest geothermal power plants. In this paper, we release raw continuous seismic waveforms and seismicity catalogues collected and prepared during this project. This dataset is particularly valuable since a very dense network was deployed in a seismically active region where thousand of earthquakes occur every year. For this reason, the collected dataset can be used across a broad range of research topics in seismology ranging from the development and testing of new data analysis methods to induced seismicity and seismotectonics studies.ISSN:2052-446
    corecore