610 research outputs found

    Performance of transition metal-doped CaCO3 during cyclic CO2 capture-and-release in low-pressure H2O vapour and H2O plasma

    Get PDF
    The effects of transition metal doping of calcium carbonate on the subsequent performance of the material during CO2 release and recapture have been evaluated for calcination under low-pressure (~0.1 mbar) water vapour and water plasma conditions. The initial samples were prepared by precipitation method from analytical grade carbonate, calcium and transition metal (Fe, Co, Zn, Cu and Ni) containing precursors. The release-recapture properties of the sorbents were monitored over five cycles involving calcination at 1200 K and carbonation at 825 K. The most noteworthy effects were observed for the Zn-doped samples, which exhibited rapid CO2 recapture. Calcination in H2O plasma was tested to evaluate the potential for in-situ material processing as a means to counteract material degradation. The impact of plasma exposure during calcination on the looping performance was mixed and dependent on the specific sample composition. The performance of the Zn-doped CaCO3 was consistently improved by plasma calcination, yielding high uptake and better retention of carrying capacity over the five cycles. All samples exhibited a deterioration in carrying capacity over repeated cycles. The Zn-doped samples also performed best in this respect (least loss of carrying capacity). The beneficial effects of Zn-doping were dependent on the Zn-content of the precursor solutions used for material synthesis.</p

    Compositional differences in soybeans on the market: glyphosate accumulates in Roundup Ready GM soybeans

    Get PDF
    This article is part of Marek Cuhra's doctoral thesis which is available in Munin at http://hdl.handle.net/10037/7869This article describes the nutrient and elemental composition, including residues of herbicides and pesticides, of 31 soybean batches from Iowa, USA. The soy samples were grouped into three different categories: (i) genetically modified, glyphosate-tolerant soy (GM-soy); (ii) unmodified soy cultivated using a conventional ‘‘chemical’’ cultivation regime; and (iii) unmodified soy cultivated using an organic cultivation regime. Organic soybeans showed the healthiest nutritional profile with more sugars, such as glucose, fructose, sucrose and maltose, significantly more total protein, zinc and less fibre than both conventional and GM-soy. Organic soybeans also contained less total saturated fat and total omega-6 fatty acids than both conventional and GM-soy. GM-soy contained high residues of glyphosate and AMPA (mean 3.3 and 5.7 mg/kg, respectively). Conventional and organic soybean batches contained none of these agrochemicals. Using 35 different nutritional and elemental variables to characterise each soy sample, we were able to discriminate GM, conventional and organic soybeans without exception, demonstrating ‘‘substantial non-equivalence’’ in compositional characteristics for ‘ready-to-market’ soybeans

    The diagnostic accuracy of headache measurement instruments: A systematic review and meta-analysis focusing on headaches associated with musculoskeletal symptoms

    Get PDF
    Contains fulltext : 208202.pdf (publisher's version ) (Open Access)AIM: To systematically review the available literature on the diagnostic accuracy of questionnaires and measurement instruments for headaches associated with musculoskeletal symptoms. DESIGN: Articles were eligible for inclusion when the diagnostic accuracy (sensitivity/specificity) was established for measurement instruments for headaches associated with musculoskeletal symptoms in an adult population. The databases searched were PubMed (1966-2018), Cochrane (1898-2018) and Cinahl (1988-2018). Methodological quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist for criterion validity. When possible, a meta-analysis was performed. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) recommendations were applied to establish the level of evidence per measurement instrument. RESULTS: From 3450 articles identified, 31 articles were included in this review. Eleven measurement instruments for migraine were identified, of which the ID-Migraine is recommended with a moderate level of evidence and a pooled sensitivity of 0.87 (95% CI: 0.85-0.89) and specificity of 0.75 (95% CI: 0.72-0.78). Six measurement instruments examined both migraine and tension-type headache and only the Headache Screening Questionnaire - Dutch version has a moderate level of evidence with a sensitivity of 0.69 (95% CI 0.55-0.80) and specificity of 0.90 (95% CI 0.77-0.96) for migraine, and a sensitivity of 0.36 (95% CI 0.21-0.54) and specificity of 0.86 (95% CI 0.74-0.92) for tension-type headache. For cervicogenic headache, only the cervical flexion rotation test was identified and had a very low level of evidence with a pooled sensitivity of 0.83 (95% CI 0.72-0.94) and specificity of 0.82 (95% CI 0.73-0.91). DISCUSSION: The current review is the first to establish an overview of the diagnostic accuracy of measurement instruments for headaches associated with musculoskeletal factors. However, as most measurement instruments were validated in one study, pooling was not always possible. Risk of bias was a serious problem for most studies, decreasing the level of evidence. More research is needed to enhance the level of evidence for existing measurement instruments for multiple headaches

    B-spline parametrization of the dielectric function applied to spectroscopic ellipsometry on amorphous carbon

    Get PDF
    The remote plasma deposition of hydrogenated amorphous carbon (a-C:H) thin films is investigated by in situ spectroscopic ellipsometry (SE). The dielectric function of the a-C:H film is in this paper parametrized by means of B-splines. In contrast with the commonly used Tauc-Lorentz oscillator, B-splines are a purely mathematical description of the dielectric function. We will show that the B-spline parametrization, which requires no prior knowledge about the film or its interaction with light, is a fast and simple-to-apply method that accurately determines thickness, surface roughness, and the dielectric constants of hydrogenated amorphous carbon thin films. Analysis of the deposition process provides us with information about the high deposition rate, the nucleation stage, and the homogeneity in depth of the deposited film. Finally, we show that the B-spline parametrization can serve as a stepping stone to physics-based models, such as the Tauc-Lorentz oscillator. © 2009 American Institute of Physics. U7 - Export Date: 24 March 2010 U7 - Source: Scopus U7 - Art. No.: 12350

    Compositional specification of functionality and timing of manufacturing systems

    Get PDF
    In this paper, a formal modeling approach is introduced for compositional specification of both functionality and timing of manufacturing systems. Functionality aspects can be considered orthogonally to the timing. The functional aspects are specified using two abstraction levels; high-level activities and lower level actions. Design of a functionally correct controller is possible by looking only at the activity level, abstracting from the different execution orders of actions. Furthermore, the specific timing of actions is not needed. As a result, controller designcan be performed on a much smaller state space compared to an explicit model where timing and actions are present. The performance of the controller can be analyzed and optimizedby taking into account the timing characteristics. Since formal semantics are given in terms of a (max, +) state space, various existing performance analysis techniques can be used. Weillustrate the approach, including performance analysis, on an example manufacturing system
    • …
    corecore