504 research outputs found
Multi-channel hardware and software complex for monitoring and analysing vibrosignals
The description of complex construction and operation principles for vibrosignal analysis is presented. The distinguishing feature of the complex is application of the wavelet analysis method. Peculiarities of wavelet transformation when solving the problems of mechanical system vibrodiagnostics in comparison with the Fourier analysis are shown. Hardware and software model of measuring complex has been created; its tests have been carries out
Development of Hydrometallurgical Process of Non-Ferrous and Rare Metals Recovery from Untraditional Mineral Raw Materials and Natural Brines
In connection with gradual lowering of supplies of tradit- ional ore raw materials involving non-ferrous and rare metals, winch is treated by well-known technologies, invo-lving into the production of untraditional, secondary and technogeneous raw materials appears to be actual task
The effectiveness of the use of various methods of shock wave therapy in the complex treatment of athletes with lateral epicondylitis
The purpose of the study: to evaluate the effectiveness of various methods of shock wave therapy in the complex treatment of athletes with lateral epicondylitis.Materials and methods: the study involved 122 people. with a diagnosis of Lateral epicondylitis, aged 20 to 45 years, of which 55 (45.1 %) women and 67 (54.9 %) men. All patients were divided into 4 groups: a control group, which included 28 people who underwent standard treatment, and 3 groups, a total of 94 people, who underwent shock wave procedures using various methods against the background of standard treatment. The examination included the collection of complaints, anamnesis, physical examination, assessment of the function of the upper limb using the QuickDASH questionnaire, assessment of tennis elbow using the PRTEE questionnaire, carpal dynamometry was performed on a MEGEON-34090 dynamometer, and statistical methods. All studies were conducted before, after treatment, as well as after 3 weeks and 1 month. after treatment.Results: shockwave therapy applied to tendons, flexors of the hand, and triceps brachii outperformed shockwaves to tendons or tendons and flexors of the hand in terms of Upper Limb Functional Activity (DASH) (p < 0,05) and score tennis elbow (PRTEE) (p < 0,05) after 3 weeks and after 1 month after treatment.Conclusion: reducing the severity of pain syndrome and functional disorders of the upper limb when performing various types of activities, when conducting shock wave therapy on the area of the tendons, flexor muscles of the hand and the triceps muscle of the shoulder indicates a faster recovery of the functions of the upper limb, which is especially important for athletes
Biomarkers of Brain Ischemia (Review)
Introduction. Strokes remain the second leading cause of death and the third leading cause of disability. Additional serum biomarker testing should be used to better diagnose transient ischemic attack (TIA), but most neurospecific biomarkers have low prognostic specificity and sensitivity. Timely identification of TIA and differential diagnosis of stroke in the first hour will ensure a shorter period of patient recovery and reduce the risk of mortality and disability. Serum biomarker studies should be included to overcome the difficulty of diagnosing TIA.Text. Neurospecific biomarkers such as S100B, GFAP, and NSE are used to diagnose acute ischemic damage to glial cells and neurons. S100B and GFAP are detected in astrocytes and NSE in neurons and cells of the neuroendocrine system. Elevated serum concentrations of these biomarkers are associated with various pathological conditions such as strokes and brain injuries and other central nervous system (CNS) lesions. Dynamic monitoring of biomarker concentrations makes it possible to evaluate the efficacy of the ongoing therapy and to identify predictors of patient deterioration for prompt correction of therapeutic procedures. To create a diagnostic panel it is necessary to study metabolic processes in ischemic tissue, taking into account concomitant diagnoses and results of neuroimaging, and to use breakthrough advances in machine learning and big data.Conclusion. The review showed that none of the assessed biomarkers can be recommended for the diagnosis of cerebral circulation disorders, but the combination of several neurospecific biomarkers can significantly improve diagnostic efficiency and find application in the differential diagnosis of stroke, intracranial hematoma, and other brain lesions for the purpose of early pharmacotherapy of CNS lesions and as surrogate endpoints during clinical trials
Search for the exotic resonance in the NOMAD experiment
A search for exotic Theta baryon via Theta -> proton +Ks decay mode in the
NOMAD muon neutrino DIS data is reported. The special background generation
procedure was developed. The proton identification criteria are tuned to
maximize the sensitivity to the Theta signal as a function of xF which allows
to study the Theta production mechanism. We do not observe any evidence for the
Theta state in the NOMAD data. We provide an upper limit on Theta production
rate at 90% CL as 2.13 per 1000 of neutrino interactions.Comment: Accepted to European Physics Journal
Robust cryogenic matched low-pass coaxial filters for quantum computing applications
Electromagnetic noise is one of the key external factors decreasing
superconducting qubits coherence. Matched coaxial filters can prevent microwave
and IR photons negative influence on superconducting quantum circuits. Here, we
report on design and fabrication route of matched low-pass coaxial filters for
noise-sensitive measurements at milliKelvin temperatures. A robust transmission
coefficient with designed linear absorption (-1dB/GHz) and ultralow reflection
losses less than -20 dB up to 20 GHz is achieved. We present a mathematical
model for evaluating and predicting filters transmission parameters depending
on their dimensions. It is experimentally approved on two filters prototypes
different lengths with compound of Cu powder and Stycast commercial resin
demonstrating excellent matching. The presented design and assembly route are
universal for various compounds and provide high repeatability of geometrical
and microwave characteristics. Finally, we demonstrate three filters with
almost equal reflection and transmission characteristics in the range from 0 to
20 GHz, which is quite useful to control multiple channel superconducting
quantum circuits.Comment: 5 pages, 4 figure
Production properties of K*(892) vector mesons and their spin alignment as measured in the NOMAD experiment
First measurements of K*(892) mesons production properties and their spin
alignment in nu_mu charged current (CC) and neutral current (NC) interactions
are presented. The analysis of the full data sample of the NOMAD experiment is
performed in different kinematic regions. For K*+ and K*- mesons produced in
nu_mu CC interactions and decaying into K0 pi+/- we have found the following
yields per event: (2.6 +/- 0.2 (stat.) +/- 0.2 (syst.))% and (1.6 +/- 0.1
(stat.) +/- 0.1 (syst.))% respectively, while for the K*+ and K*- mesons
produced in nu NC interactions the corresponding yields per event are: (2.5 +/-
0.3 (stat.) +/- 0.3 (syst.))% and (1.0 +/- 0.3 (stat.) +/- 0.2 (syst.))%. The
results obtained for the rho00 parameter, 0.40 +/- 0.06 (stat) +/- 0.03 (syst)
and 0.28 +/- 0.07 (stat) +/- 0.03 (syst) for K*+ and K*- produced in nu_mu CC
interactions, are compared to theoretical predictions tuned on LEP measurements
in e+e- annihilation at the Z0 pole. For K*+ mesons produced in nu NC
interactions the measured rho00 parameter is 0.66 +/- 0.10 (stat) +/- 0.05
(syst).Comment: 20 p
- …