504 research outputs found

    Multi-channel hardware and software complex for monitoring and analysing vibrosignals

    Get PDF
    The description of complex construction and operation principles for vibrosignal analysis is presented. The distinguishing feature of the complex is application of the wavelet analysis method. Peculiarities of wavelet transformation when solving the problems of mechanical system vibrodiagnostics in comparison with the Fourier analysis are shown. Hardware and software model of measuring complex has been created; its tests have been carries out

    Development of Hydrometallurgical Process of Non-Ferrous and Rare Metals Recovery from Untraditional Mineral Raw Materials and Natural Brines

    Get PDF
    In connection with gradual lowering of supplies of tradit- ional ore raw materials involving non-ferrous and rare metals, winch is treated by well-known technologies, invo-lving into the production of untraditional, secondary and technogeneous raw materials appears to be actual task

    The effectiveness of the use of various methods of shock wave therapy in the complex treatment of athletes with lateral epicondylitis

    Get PDF
    The purpose of the study: to evaluate the effectiveness of various methods of shock wave therapy in the complex treatment of athletes with lateral epicondylitis.Materials and methods: the study involved 122 people. with a diagnosis of Lateral epicondylitis, aged 20 to 45 years, of which 55 (45.1 %) women and 67 (54.9 %) men. All patients were divided into 4 groups: a control group, which included 28 people who underwent standard treatment, and 3 groups, a total of 94 people, who underwent shock wave procedures using various methods against the background of standard treatment. The examination included the collection of complaints, anamnesis, physical examination, assessment of the function of the upper limb using the QuickDASH questionnaire, assessment of tennis elbow using the PRTEE questionnaire, carpal dynamometry was performed on a MEGEON-34090 dynamometer, and statistical methods. All studies were conducted before, after treatment, as well as after 3 weeks and 1 month. after treatment.Results: shockwave therapy applied to tendons, flexors of the hand, and triceps brachii outperformed shockwaves to tendons or tendons and flexors of the hand in terms of Upper Limb Functional Activity (DASH) (p < 0,05) and score tennis elbow (PRTEE) (p < 0,05) after 3 weeks and after 1 month after treatment.Conclusion: reducing the severity of pain syndrome and functional disorders of the upper limb when performing various types of activities, when conducting shock wave therapy on the area of the tendons, flexor muscles of the hand and the triceps muscle of the shoulder indicates a faster recovery of the functions of the upper limb, which is especially important for athletes

    Biomarkers of Brain Ischemia (Review)

    Get PDF
    Introduction. Strokes remain the second leading cause of death and the third leading cause of disability. Additional serum biomarker testing should be used to better diagnose transient ischemic attack (TIA), but most neurospecific biomarkers have low prognostic specificity and sensitivity. Timely identification of TIA and differential diagnosis of stroke in the first hour will ensure a shorter period of patient recovery and reduce the risk of mortality and disability. Serum biomarker studies should be included to overcome the difficulty of diagnosing TIA.Text. Neurospecific biomarkers such as S100B, GFAP, and NSE are used to diagnose acute ischemic damage to glial cells and neurons. S100B and GFAP are detected in astrocytes and NSE in neurons and cells of the neuroendocrine system. Elevated serum concentrations of these biomarkers are associated with various pathological conditions such as strokes and brain injuries and other central nervous system (CNS) lesions. Dynamic monitoring of biomarker concentrations makes it possible to evaluate the efficacy of the ongoing therapy and to identify predictors of patient deterioration for prompt correction of therapeutic procedures. To create a diagnostic panel it is necessary to study metabolic processes in ischemic tissue, taking into account concomitant diagnoses and results of neuroimaging, and to use breakthrough advances in machine learning and big data.Conclusion. The review showed that none of the assessed biomarkers can be recommended for the diagnosis of cerebral circulation disorders, but the combination of several neurospecific biomarkers can significantly improve diagnostic efficiency and find application in the differential diagnosis of stroke, intracranial hematoma, and other brain lesions for the purpose of early pharmacotherapy of CNS lesions and as surrogate endpoints during clinical trials

    Search for the exotic Θ+\Theta^+ resonance in the NOMAD experiment

    Get PDF
    A search for exotic Theta baryon via Theta -> proton +Ks decay mode in the NOMAD muon neutrino DIS data is reported. The special background generation procedure was developed. The proton identification criteria are tuned to maximize the sensitivity to the Theta signal as a function of xF which allows to study the Theta production mechanism. We do not observe any evidence for the Theta state in the NOMAD data. We provide an upper limit on Theta production rate at 90% CL as 2.13 per 1000 of neutrino interactions.Comment: Accepted to European Physics Journal

    Robust cryogenic matched low-pass coaxial filters for quantum computing applications

    Full text link
    Electromagnetic noise is one of the key external factors decreasing superconducting qubits coherence. Matched coaxial filters can prevent microwave and IR photons negative influence on superconducting quantum circuits. Here, we report on design and fabrication route of matched low-pass coaxial filters for noise-sensitive measurements at milliKelvin temperatures. A robust transmission coefficient with designed linear absorption (-1dB/GHz) and ultralow reflection losses less than -20 dB up to 20 GHz is achieved. We present a mathematical model for evaluating and predicting filters transmission parameters depending on their dimensions. It is experimentally approved on two filters prototypes different lengths with compound of Cu powder and Stycast commercial resin demonstrating excellent matching. The presented design and assembly route are universal for various compounds and provide high repeatability of geometrical and microwave characteristics. Finally, we demonstrate three filters with almost equal reflection and transmission characteristics in the range from 0 to 20 GHz, which is quite useful to control multiple channel superconducting quantum circuits.Comment: 5 pages, 4 figure

    Production properties of K*(892) vector mesons and their spin alignment as measured in the NOMAD experiment

    Get PDF
    First measurements of K*(892) mesons production properties and their spin alignment in nu_mu charged current (CC) and neutral current (NC) interactions are presented. The analysis of the full data sample of the NOMAD experiment is performed in different kinematic regions. For K*+ and K*- mesons produced in nu_mu CC interactions and decaying into K0 pi+/- we have found the following yields per event: (2.6 +/- 0.2 (stat.) +/- 0.2 (syst.))% and (1.6 +/- 0.1 (stat.) +/- 0.1 (syst.))% respectively, while for the K*+ and K*- mesons produced in nu NC interactions the corresponding yields per event are: (2.5 +/- 0.3 (stat.) +/- 0.3 (syst.))% and (1.0 +/- 0.3 (stat.) +/- 0.2 (syst.))%. The results obtained for the rho00 parameter, 0.40 +/- 0.06 (stat) +/- 0.03 (syst) and 0.28 +/- 0.07 (stat) +/- 0.03 (syst) for K*+ and K*- produced in nu_mu CC interactions, are compared to theoretical predictions tuned on LEP measurements in e+e- annihilation at the Z0 pole. For K*+ mesons produced in nu NC interactions the measured rho00 parameter is 0.66 +/- 0.10 (stat) +/- 0.05 (syst).Comment: 20 p
    corecore