396 research outputs found

    Iridoschisis and keratoconus in a patient with severe allergic eye disease and compulsive eye rubbing: a case report

    Get PDF
    Background Iridoschisis is a rare disorder characterized by splitting of the anterior and posterior iris stroma, resulting in disintegrated iris fibrils which float freely in the anterior chamber. We report an exceptional case of bilateral iridoschisis occurring in conjunction with keratoconus and severe allergic eye disease. Case Presentation A 24-year-old white man had had periocular contact dermatitis and allergic eye disease from the age of 3 years. He was allergic to grass, animal hair, and pollen and worked grooming horses. He compulsively rubbed his eyes. There was no history of previous blunt trauma to either eye. There were signs of bilateral iridoschisis and keratoconus with allergic conjunctivitis, all of which were more severe in his right eye. An open drainage angle was identified bilaterally on gonioscopy, excluding primary angle closure. There was no evidence of glaucoma in either eye. Conclusions There are two previous cases reporting the combination of iridoschisis and keratoconus, but no clear common etiology has been identified. In this case there was no evidence of angle closure but there were signs of allergic conjunctivitis. This amalgamation of signs might be explained on the basis of habitual eye rubbing. Treating the allergic eye disease has attenuated this behavior.</p

    Final report of the Committee on Depreciation; Dissenting opinion to the final report of the Committee on Depreciation

    Get PDF
    Losses of value which are complete, and fully demonstrated by proper abandonment or necessary replacement of the whole or a unit part of a property, are a matter of history and fact, and require only proper accounting to determine their occurrence and amount. Losses of value, which are partial or incomplete, always require prophecy as to future need, usefulness, and service, in order to properly divide that portion of the value which still exists from that which is lost. This function necessitates much more judgment than accounting. It requires the careful analysis of a broadly trained, experienced, and practical mind, thoroughly familiar with the business in question. Original item in Boxno. 0409

    Anaphylactic response to topical fluorescein 2% eye drops: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>The intravenous use of fluorescein 10% during retinal angiography can cause severe systemic reactions including, on rare occasions, anaphylaxis. Fluorescein 2% eye drops are used extensively for clinical examination and diagnosis, but to the best of our knowledge, they have only been reported as being responsible for a systemic anaphylactic response on two previous occasions.</p> <p>Case presentation</p> <p>We report the case of a 51-year-old woman who developed an anaphylactic reaction when she was administered fluorescein sodium 2% eye drops after cataract surgery. This was the second time she had been exposed to fluorescein. She had brittle asthma and a history of anaphylaxis following exposure to a variety of drug and food allergens. She was successfully resuscitated and recovered completely over a period of two days.</p> <p>Conclusions</p> <p>Fluorescein 2% drops are universally used in general practice, ophthalmology, optometry, and casualty departments. Our case report reveals the potential for this benign eye drop to cause a life-threatening systemic reaction and emphasises the importance of considering this consequence when administering topical fluorescein 2% to a patient with a history of anaphylaxis to other allergens.</p

    Early rheumatoid arthritis is characterized by a distinct and transient synovial fluid cytokine profile of T cell and stromal cell origin

    Get PDF
    Pathological processes involved in the initiation of rheumatoid synovitis remain unclear. We undertook the present study to identify immune and stromal processes that are present soon after the clinical onset of rheumatoid arthritis ( RA) by assessing a panel of T cell, macrophage, and stromal cell related cytokines and chemokines in the synovial fluid of patients with early synovitis. Synovial fluid was aspirated from inflamed joints of patients with inflammatory arthritis of duration 3 months or less, whose outcomes were subsequently determined by follow up. For comparison, synovial fluid was aspirated from patients with acute crystal arthritis, established RA and osteoarthritis. Rheumatoid factor activity was blocked in the synovial fluid samples, and a panel of 23 cytokines and chemokines measured using a multiplex based system. Patients with early inflammatory arthritis who subsequently developed RA had a distinct but transient synovial fluid cytokine profile. The levels of a range of T cell, macrophage and stromal cell related cytokines ( e. g. IL-2, IL-4, IL-13, IL-17, IL-15, basic fibroblast growth factor and epidermal growth factor) were significantly elevated in these patients within 3 months after symptom onset, as compared with early arthritis patients who did not develop RA. In addition, this profile was no longer present in established RA. In contrast, patients with non-rheumatoid persistent synovitis exhibited elevated levels of interferon-gamma at initiation. Early synovitis destined to develop into RA is thus characterized by a distinct and transient synovial fluid cytokine profile. The cytokines present in the early rheumatoid lesion suggest that this response is likely to influence the microenvironment required for persistent RA

    Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

    Get PDF
    The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysic
    • …
    corecore