48,881 research outputs found

    Gas chromatograph sample-transfer valve

    Get PDF
    Slide-type gate valve incorporates sampling volume and transfer passageway for guiding a metered quantity of gas from pressurized test cell to gas chromatograph. Gate is moved by pneumatic bellows-type actuator

    Miniature high pressure regulator

    Get PDF
    Metal bellows, capable of suppling required spring rate and operational stability, replaced diaphragms, sliding seals, and springs in design of small gas regulator

    Two-stage coaxial gas compressor

    Get PDF
    Compressor raises pressure of gases from low ambient supply during space experiments by a system of low weight, size, and power input. Dc rotary-torque motor and ball-screw drive shaft activate first and second stage of compressor, utilizing inertia forces to operate check valves

    Slow states in thin film transistors

    Get PDF
    Imperial Users onl

    A prospective clinical comparison of two intravenous polyurethane cannulae

    Get PDF
    Publisher's copy made available with the permission of the publisher © 1997 Australian Society of Anaesthetists "Because of a printer's error in the December 1996 issue of Anaesthesia and Intensive Care (Vol. 24, No. 6, p. 708, Figure 4) this paper is reprinted here in its entirety and in its correct form"--cf. p.42Tissue irritation, as evidenced by phlebitis, associated with Optiva™ (Johnson & Johnson Medical) and Insyte™ (Becton Dickinson) polyurethane cannulae was studied. The integrity of the cannulae on removal, the incidence of infection at the cannula site and the factors which influence phlebitis were also examined. One thousand and eight patients had a polyurethane cannula placed for induction of anaesthesia for cardiac surgery. After surgery, the cannula was examined every 24 hours. If evidence of phlebitis occurred, the cannula was removed and sent for culture. All remaining cannulae were removed at 72 hours and the site examined daily for a further three days. There were 503 Optiva™ and 505 Insyte™ cannulae studied. The distributions between the two cannulae with respect to patient characteristics, gauge of cannula, number of attempts and difficulty of insertion, cannula site and anaesthetist inserting were similar. The early removal rate for both groups was 47%. Overall phlebitis rate with Optiva™ was 31% and Insyte™ 33%. This difference is not statistically significant. The cumulative phlebitis rate increased with time but did not differ between the two types of cannulae. Minor tip distortion or shaft kinking of the cannulae occurred in 16.2% of Optiva™ and 23.5% of Insyte™. This difference is statistically significant and may relate to the slightly more acute taper at the Optiva™ cannula tip. Both cannulae were similar in clinical performance.W.J. Russell, S. Micik, S. Gourd, H. Mackay, S. Wrigh

    Development of a system for remote sensing of ionospheric motions and microstructure - The Kinesonde in France, 1970

    Get PDF
    Kinesonde experiment for development of system for remote sensing of ionospheric motions and microstructur

    Attraction of Acorn-Infesting \u3ci\u3eCydia Latiferreana\u3c/i\u3e (Lepidoptera: Tortricidae) to Pheromone-Baited Traps

    Get PDF
    Males of acorn-infesting Cydia latiferreana are attracted to an equilibrium mixture of the four isomers of 8, 10-dodecadien-l-ol acetate, the virgin female-produced pheromone. Trap height relative to the height of trees in which traps are placed seems to be a significant factor influencing moth catches at attractant-baited traps. In an oak woodlot and in an oak nursery, catches of male moths were greater in traps placed near the upper periphery of the canopy than at traps deployed at lower levels in the tree. Practical application of pheromone-baited traps in a forest situation will require further study on lure formulation and on trap deployment under forest conditions

    Studies in a transonic rotor aerodynamics and noise facility

    Get PDF
    The design, construction and testing of a transonic rotor aerodynamics and noise facility was undertaken, using a rotating arm blade element support technique. This approach provides a research capability intermediate between that of a stationary element in a moving flow and that of a complete rotating blade system, and permits the acoustic properties of blade tip elements to be studied in isolation. This approach is an inexpensive means of obtaining data at high subsonic and transonic tip speeds on the effect of variations in tip geometry. The facility may be suitable for research on broad band noise and discrete noise in addition to high-speed noise. Initial tests were conducted over the Mach number range 0.3 to 0.93 and confirmed the adequacy of the acoustic treatment used in the facility to avoid reflection from the enclosure
    • …
    corecore