4 research outputs found

    Coulomb dissociation of 16O into 4He and 12C

    Get PDF
    We measured the Coulomb dissociation of 16O into 4He and 12C at the R3B setup in a first campaign within FAIR Phase 0 at GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt. The goal was to improve the accuracy of the experimental data for the 12C(a,?)16O fusion reaction and to reach lower center-ofmass energies than measured so far. The experiment required beam intensities of 109 16O ions per second at an energy of 500 MeV/nucleon. The rare case of Coulomb breakup into 12C and 4He posed another challenge: The magnetic rigidities of the particles are so close because of the same mass-To-charge-number ratio A/Z = 2 for 16O, 12C and 4He. Hence, radical changes of the R3B setup were necessary. All detectors had slits to allow the passage of the unreacted 16O ions, while 4He and 12C would hit the detectors' active areas depending on the scattering angle and their relative energies. We developed and built detectors based on organic scintillators to track and identify the reaction products with sufficient precision

    Real-time left ventricular pressure-volume loops during percutaneous mitral valve repair with the MitraClip system

    Full text link
    BACKGROUND: Percutaneous mitral valve repair with the MitraClip device has emerged as an alternative to surgery for treating severe mitral regurgitation. However, its effects on left ventricular loading conditions and contractility have not been investigated yet. METHODS AND RESULTS: Pressure-volume loops were recorded throughout the MitraClip procedure using conductance catheter in 33 patients (mean age, 78±10 years) with functional (45%), degenerative (48%), or mixed (6%) mitral regurgitation. Percutaneous mitral valve repair increased end-systolic wall stress (WSES; from [median] 184 mm Hg [interquartile range (IQR), 140-200 mm Hg] to 209 mm Hg [IQR, 176-232 mm Hg]; P=0.001) and decreased end-diastolic WS (WSED; from 48 mm Hg [IQR, 28-58 mm Hg] to 34 mm Hg [IQR, 21-46 mm Hg]; P=0.005), whereas the end-systolic pressure-volume relationship was not significantly affected. Conversely, cardiac index increased (from 2.6 L·min(-1)·m(-2) [IQR, 2.2-3.0 L·min(-1)·m(-2)] to 3.2 L·min(-1)·m(-2) [IQR, 2.6-3.8 L·min(-1)·m(-2)]; P<0.001) and mean pulmonary capillary wedge pressure decreased (from 15 mm Hg [IQR, 12-20 mm Hg] to 12 mm Hg [IQR, 10-13 mm Hg]; P<0.001). Although changes in WSES were not correlated with changes in cardiac index, changes in WSED correlated significantly with changes in mean pulmonary capillary wedge pressure (r=0.63, P<0.001). Total mechanical energy assessed by the pressure-volume area remained unchanged, resulting in a more favorable index of forward output (cardiac index) to mechanical energy (pressure-volume area) after mitral valve repair. On follow-up (153±94 days), New York Heart Association functional class was reduced from 2.9±0.6 to 1.9±0.5 (P<0.001) at 3 months, and echocardiographic follow-up documented a stepwise reduction in end-diastolic volume (from 147 mL [IQR, 95-191 mL] to 127 mL [IQR, 82-202 mL]; P=0.036). CONCLUSIONS: Percutaneous mitral valve repair improves hemodynamic profiles and induces reverse left ventricular remodeling by reducing left ventricular preload while preserving contractility. In nonsurgical candidates with compromised left ventricular function, MitraClip therapy could be considered an alternative to surgical mitral valve repair

    A new Time-of-flight detector for the R 3 B setup

    No full text
    © 2022, The Author(s).We present the design, prototype developments and test results of the new time-of-flight detector (ToFD) which is part of the R3B experimental setup at GSI and FAIR, Darmstadt, Germany. The ToFD detector is able to detect heavy-ion residues of all charges at relativistic energies with a relative energy precision σΔE/ ΔE of up to 1% and a time precision of up to 14 ps (sigma). Together with an elaborate particle-tracking system, the full identification of relativistic ions from hydrogen up to uranium in mass and nuclear charge is possible.11Nsciescopu
    corecore