9 research outputs found

    Quantitative Analysis of the Membrane Affinity of Local Anesthetics Using a Model Cell Membrane.

    Get PDF
    Local anesthesia is a drug that penetrates the nerve cell membrane and binds to the voltage gate sodium channel, inhibiting the membrane potential and neurotransmission. It is mainly used in clinical uses to address the pain of surgical procedures in the local area. Local anesthetics (LAs), however, can be incorporated into the membrane, reducing the thermal stability of the membrane as well as altering membrane properties such as fluidity, permeability, and lipid packing order. The effects of LAs on the membrane are not yet fully understood, despite a number of previous studies. In particular, it is necessary to analyze which is the more dominant factor, the membrane affinity or the structural perturbation of the membrane. To analyze the effects of LAs on the cell membrane and compare the results with those from model membranes, morphological analysis and 50% inhibitory concentration (IC50) measurement of CCD-1064sk (fibroblast, human skin) membranes were carried out for lidocaine (LDC) and tetracaine (TTC), the most popular LAs in clinical use. Furthermore, the membrane affinity of the LAs was quantitatively analyzed using a colorimetric polydiacetylene assay, where the color shift represents their distribution in the membrane. Further, to confirm the membrane affinity and structural effects of the membranes, we performed an electrophysiological study using a model protein (gramicidin A, gA) and measured the channel lifetime of the model protein on the free-standing lipid bilayer according to the concentration of each LA. Our results show that when LAs interact with cell membranes, membrane affinity is a more dominant factor than steric or conformational effects of the membrane

    Biomimetic Membranes with Transmembrane Proteins: State-of-the-Art in Transmembrane Protein Applications

    No full text
    In biological cells, membrane proteins are the most crucial component for the maintenance of cell physiology and processes, including ion transportation, cell signaling, cell adhesion, and recognition of signal molecules. Therefore, researchers have proposed a number of membrane platforms to mimic the biological cell environment for transmembrane protein incorporation. The performance and selectivity of these transmembrane proteins based biomimetic platforms are far superior to those of traditional material platforms, but their lack of stability and scalability rule out their commercial presence. This review highlights the development of transmembrane protein-based biomimetic platforms for four major applications, which are biosensors, molecular interaction studies, energy harvesting, and water purification. We summarize the fundamental principles and recent progress in transmembrane protein biomimetic platforms for each application, discuss their limitations, and present future outlooks for industrial implementation

    Biodistribution and respiratory toxicity of chloromethylisothiazolinone/methylisothiazolinone following intranasal and intratracheal administration

    No full text
    A variety of isothiazolinone-containing small molecules have been registered and used as chemical additives in many household products. However, their biodistribution and potential harmful effects on human health, especially respiratory effects, were not yet identified in sufficient detail. The purpose of this study was to investigate whether a biocide comprising a mixture of chloromethylisothiazolinone (CMIT) and methylisothiazolinone (MIT) could reach the lungs and induce lung injury when exposure occurs by two administration routes involving the respiratory tract: intratracheal and intranasal instillation. To investigate the biodistribution of CMIT/MIT, we quantified the uptake of 14C-labeled CMIT/MIT in experimental animals for up to seven days after intratracheal and intranasal instillation. In the toxicity study, lung injury was assessed in mice using total inflammatory cell count in bronchoalveolar lavage fluid (BALF) and lung histopathology. The results of the biodistribution study indicated that CMIT/MIT were rapidly distributed throughout the respiratory tract. Using quantitative whole-body autoradiogram analysis, we confirmed that following intranasal exposure, CMIT/MIT reached the lungs via the respiratory tract (nose–trachea–lung). After 5 min post intratracheal and intranasal instillation, the amount of radiotracer ([14C]CMIT/MIT) in the lungs was 2720 ng g−1 and 752 ng g−1 tissue, respectively, and lung damage was observed. A higher amount of the radiotracer resulted in higher toxicity. Both intratracheal and intranasal instillation of CMIT/MIT increased inflammatory cell counts in the BALF and induced injuries in the alveoli. The frequency and the severity scores of injuries caused by intratracheal instillation were approximately-four to five times higher than those induced by intranasal instillation. Therefore, we concluded that CMIT/MIT could reach the lungs following nasal and intratracheal exposure and cause lung injuries, and the extent of injury was dependent on the exposure dose

    Automated Lipid Membrane Formation Using a Polydimethylsiloxane Film for Ion Channel Measurements

    No full text
    A black lipid membrane (BLM) is a powerful platform for studying the electrophysiology of cell membranes as well as transmembrane proteins. However, BLMs have disadvantages in terms of stability, accessibility, and transportability, which preclude their industrial applications. To resolve these issues, frozen membrane precursor (MP) was devised to improve the transportability and storability of BLMs. As described previously, MP is a storable and transportable platform that can be delivered to the point-of-use, where BLMs are automatically formed upon thawing at room temperature. However, MP has an inconsistent thinning-out time, ranging from 30 min to 24 h, as well as a low success rate of BLM formation (∼27%), which make it undesirable for practical use. In our study, polydimethylsiloxane (PDMS) was introduced as a replacement for conventionally used Teflon film to control thinning-out time. As such, we used a PDMS thin-film, a porous-structured hydrophobic polymer, and squalene, a high viscosity solvent, to facilitate membrane formation, whereas the absorption rates of solvents were controlled to achieve consistent BLM formation time. We successfully reduced thinning-out time down to <1 h as well as enhanced the success rate of BLM formation to greater than 80%. Moreover, we demonstrated the feasibility of our platform for use in drug screening using gramicidin A and guanidine
    corecore