81 research outputs found

    Geometric parameterisation of pelvic bone and cartilage in contact analysis of the natural hip: an initial study

    Get PDF
    Parameterised finite element models of the human hip have the potential to allow controlled analysis of the effect of individual geometric features on the contact mechanics of the joint. However, the challenge lies in defining a set of parameters which sufficiently capture the joint geometry in order to distinguish between individuals. In this study, a simple set of parameters to describe the geometries of acetabulum and cartilage in the hip were extracted from two segmentation-based models, which were then used to generate the parameterised finite element models for the two subjects. The contact pressure and contact area at the articular surface predicted from the parameterised finite element models were compared with the results from the segmentation-based models. The differences in the predicted results between the parameterised models and segmentation-based models were found to be within 11% across seven activities simulated. In addition, the parameterised models were able to replicate features of the contact pressure/area fluctuations over the loading cycle that differed between the two subjects. These results provide confidence that the parameterised approach could be used to generate representative finite element models of the human hip for contact analysis. Such a method has the potential to be used to systematically evaluate geometric features that can be captured from simple clinical measurements and provide a cost- and time-effective approach for stratification of the acetabular geometries in the patient population

    Development of calcium phosphate cement for the augmentation of traumatically fractured porcine specimens using vertebroplasty

    Get PDF
    AbstractThe study aim was to develop and apply an experimental technique to determine the biomechanical effect of polymethylmethacrylate (PMMA) and calcium phosphate (CaP) cement on the stiffness and strength of augmented vertebrae following traumatic fracture. Twelve burst type fractures were generated in porcine three-vertebra segments. The specimens were randomly split into two groups (n=6), imaged using microCT and tested under axial loading. The two groups of fractured specimens underwent a vertebroplasty procedure, one group was augmented with CaP cement designed and developed at Queen's University Belfast. The other group was augmented with PMMA cement (WHW Plastics, Hull, UK). The specimens were imaged and re-tested . An intact single vertebra specimen group (n=12) was also imaged and tested under axial loading. A significant decrease (p<0.01) was found between the stiffness of the fractured and intact groups, demonstrating that the fractures generated were sufficiently severe, to adversely affect mechanical behaviour. Significant increase (p<0.01) in failure load was found for the specimen group augmented with the PMMA cement compared to the pre-augmentation group, conversely, no significant increase (p<0.01) was found in the failure load of the specimens augmented with CaP cement, this is attributed to the significantly (p<0.05) lower volume of CaP cement that was successfully injected into the fracture, compared to the PMMA cement. The effect of the percentage of cement fracture fill, cement modulus on the specimen stiffness and ultimate failure load could be investigated further by using the methods developed within this study to test a more injectable CaP cement

    Controlling the self-assembly and material properties of β-sheet peptide hydrogels by modulating intermolecular interactions

    Get PDF
    Self-assembling peptides are a promising biomaterial with potential applications in medical devices and drug delivery. In the right combination of conditions, self-assembling peptides can form self-supporting hydrogels. Here, we describe how balancing attractive and repulsive intermolecular forces is critical for successful hydrogel formation. Electrostatic repulsion is tuned by altering the peptide’s net charge, and intermolecular attractions are controlled through the degree of hydrogen bonding between specific amino acid residues. We find that an overall net peptide charge of +/−2 is optimal to facilitate the assembly of self-supporting hydrogels. If the net peptide charge is too low then dense aggregates form, while a high molecular charge inhibits the formation of larger structures. At a constant charge, altering the terminal amino acids from glutamine to serine decreases the degree of hydrogen bonding within the assembling network. This tunes the viscoelastic properties of the gel, reducing the elastic modulus by two to three orders of magnitude. Finally, hydrogels could be formed from glutamine-rich, highly charged peptides by mixing the peptides in combinations with a resultant net charge of +/−2. These results illustrate how understanding and controlling self-assembly mechanisms through modulating intermolecular interactions can be exploited to derive a range of structures with tuneable properties

    Comparative finite-element analysis: a single computational modelling method can estimate the mechanical properties of porcine and human vertebrae

    Get PDF
    Significant advances in the functional analysis of musculoskeletal systems require the development of modelling techniques with improved focus, accuracy and validity. This need is particularly visible in the fields, such as palaeontology, where unobservable parameters may lie at the heart of the most interesting research questions, and where models and simulations may provide some of the most innovative solutions. Here, we report on the development of a computational modelling method to generate estimates of the mechanical properties of vertebral bone across two living species, using elderly human and juvenile porcine specimens as cases with very different levels of bone volume fraction and mineralization. This study is presented in two parts; part I presents the computational model development and validation, and part II the virtual loading regime and results. This work paves the way for the future estimation of mechanical properties in fossil mammalian bone

    Patterns of analgesic use, pain and self-efficacy: a cross-sectional study of patients attending a hospital rheumatology clinic

    Get PDF
    Background: Many people attending rheumatology clinics use analgesics and non-steroidal anti-inflammatories for persistent musculoskeletal pain. Guidelines for pain management recommend regular and pre-emptive use of analgesics to reduce the impact of pain. Clinical experience indicates that analgesics are often not used in this way. Studies exploring use of analgesics in arthritis have historically measured adherence to such medication. Here we examine patterns of analgesic use and their relationships to pain, self-efficacy and demographic factors. Methods: Consecutive patients were approached in a hospital rheumatology out-patient clinic. Pattern of analgesic use was assessed by response to statements such as 'I always take my tablets every day.' Pain and self-efficacy (SE) were measured using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Arthritis Self-Efficacy Scale (ASES). Influence of factors on pain level and regularity of analgesic use were investigated using linear regression. Differences in pain between those agreeing and disagreeing with statements regarding analgesic use were assessed using t-tests. Results: 218 patients (85% of attendees) completed the study. Six (2.8%) patients reported no current pain, 26 (12.3%) slight, 100 (47.4%) moderate, 62 (29.4%) severe and 17 (8.1%) extreme pain. In multiple linear regression self efficacy and regularity of analgesic use were significant (p < 0.01) with lower self efficacy and more regular use of analgesics associated with more pain. Low SE was associated with greater pain: 40 (41.7%) people with low SE reported severe pain versus 22 (18.3%) people with high SE, p < 0.001. Patients in greater pain were significantly more likely to take analgesics regularly; 13 (77%) of those in extreme pain reported always taking their analgesics every day, versus 9 (35%) in slight pain. Many patients, including 46% of those in severe pain, adjusted analgesic use to current pain level. In simple linear regression, pain was the only variable significantly associated with regularity of analgesic use: higher levels of pain corresponded to more regular analgesic use (p = 0.003). Conclusion: Our study confirms that there is a strong inverse relationship between self-efficacy and pain severity. Analgesics are often used irregularly by people with arthritis, including some reporting severe pain

    Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: a finite element study with biphasic acetabular cartilage properties

    Get PDF
    Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries

    Vertebroplasty: patient and treatment variations studied through parametric computational models

    Get PDF
    Background Vertebroplasty is increasingly used in the treatment of vertebral compression fractures. However there are concerns that this intervention may lead to further fractures in the adjacent vertebral segments. This study was designed to parametrically assess the influence of both treatment factors (cement volume and number of augmentations), and patient factors (bone and disc quality) on the biomechanical effects of vertebroplasty. Methods Specimen-specific finite element models of two experimentally-tested human three-vertebral-segments were developed from CT-scan data. Cement augmentation at one and two levels was represented in the respective models and good agreement in the predicted stiffness was found compared to the corresponding experimental specimens. Parametric variations of key variables associated with the procedure were then studied. Findings The segmental stiffness increased with disc degeneration, with increasing bone quality and to a lesser extent with increasing cement volume. Cement modulus did not have a great influence on the overall segmental stiffness and on the change in the elemental stress in the adjoining vertebrae. However, following augmentation, the stress distribution in the adjacent vertebra changed, indicating possible load redistribution effects of vertebroplasty. Interpretation This study demonstrates the importance of patient factors in the outcomes of vertebroplasty and suggests that these may be one reason for the variation in clinical results

    The influence of size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the hip joint with biphasic layers

    Get PDF
    Computational models of the natural hip joint are needed to examine and optimise tissue sparing interventions where the natural cartilage remains part of the bearing surfaces. Although the importance of interstitial fluid pressurisation in the performance of cartilage has long been recognized, few studies have investigated the time dependent interstitial fluid pressurisation in a three dimensional natural hip joint model. The primary aim of this study was to develop a finite element model of the natural hip incorporating the biphasic cartilage layers that was capable of simulating the joint response over a prolonged physiological loading period. An initial set of sensitivity studies were also undertaken to investigate the influence of hip size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the joint. The contact stress, contact area, fluid pressure and fluid support ratio were calculated and cross-compared between models with different parameters to evaluate their influence. It was found that the model predictions for the period soon after loading were sensitive to the hip size, clearance, cartilage aggregate modulus, thickness and hemiarthroplasty, while the time dependent behaviour over 3000s was influenced by the hip clearance and cartilage aggregate modulus, permeability, thickness and hemiarthroplasty. The modelling methods developed in this study provide a basic platform for biphasic simulation of the whole hip joint onto which more sophisticated material models or other input parameters could be added in the future

    The influence of the representation of collagen fibre organisation on the cartilage contact mechanics of the hip joint

    Get PDF
    The aim of this study was to develop a finite element (FE) hip model with subject-specific geometry and biphasic cartilage properties. Different levels of detail in the representation of fibre reinforcement were considered to evaluate the feasibility to simplify the complex depth-dependent fibre pattern in the native hip joint. A FE model of a cadaveric hip with subject-specific geometry was constructed through micro-computed-tomography (µCT) imaging. The cartilage was assumed to be biphasic and fibre-reinforced with different levels of detail in the fibre representation. Simulations were performed for heel-strike, mid-stance and toe-off during walking and one-leg-stance over 1500s. It was found that the required level of detail in fibre representation depends on the parameter of interest. The contact stress of the native hip joint could be realistically predicted by simplifying the fibre representation to being orthogonally reinforced across the whole thickness. To predict the fluid pressure, depth-dependent fibre organisation is needed but specific split-line pattern on the surface of cartilage is not necessary. Both depth-dependent and specific surface fibre orientations are required to simulate the strains