135 research outputs found

    High efficiency proton beam generation through target thickness control in femtosecond laser-plasma interactions

    Get PDF
    Bright proton beams with maximum energies of up to 30MeV have been observed in an experiment investigating ion sheath acceleration driven by a short pulse (21 W cm-2 was investigated, with the interplay between target thickness and laser pre-pulse found to be a key factor. While the maximum proton energies observed were maximised for lm-thick targets, the total proton energy content was seen to peak for thinner, 500 nm, foils. The total proton beam energy reached up to 440 mJ (a conversion efficiency of 4%), marking a significant step forward for many laser-driven ion applications. The experimental results are supported by hydrodynamic and particle-in-cell simulations

    Measurement of the angle, temperature and flux of fast electrons emitted from intense laser-solid interactions

    Get PDF
    High-intensity laser-solid interactions generate relativistic electrons, as well as high-energy (multi-MeV) ions and X-rays. The directionality, spectra and total number of electrons that escape atarget-foil is dependent on the absorption, transport and rear-side sheath conditions. Measuring the electrons escaping the target will aid in improving our understanding of these absorption processes and the rear-surface sheath fields that retard the escaping electrons and accelerate ions via the target normal sheath acceleration (TNSA) mechanism. A comprehensive Geant4 study was performed to help analyse measurements made with a wrap-around diagnostic that surrounds the target and uses differential filtering with a FUJI-film image plate detector. The contribution of secondary sources such as X-rays and protons to the measured signal have been taken into account to aid in the retrieval of the electron signal. Angular and spectral data from a high-intensity laser-solid interaction are presented and accompanied by simulations. The total number of emitted electrons has been measured as 2.6 × 1013 with an estimated total energy of 12 ± 1 J from a 100 mu;m Cu target with140 J of incident laser energy during a 4 × 1020 W cm-2 interaction

    Reflection of intense laser light from microstructured targets as a potential diagnostic of laser focus and plasma temperature

    Get PDF
    The spatial-intensity profile of light reflected during the interaction of an intense laser pulse with a microstructured target is investigated experimentally and the potential to apply this as a diagnostic of the interaction physics is explored numerically. Diffraction and speckle patterns are measured in the specularly reflected light in the cases of targets with regular groove and needle-like structures, respectively, highlighting the potential to use this as a diagnostic of the evolving plasma surface. It is shown, via ray-tracing and numerical modelling, that for a laser focal spot diameter smaller than the periodicity of the target structure, the reflected light patterns can potentially be used to diagnose the degree of plasma expansion, and by extension the local plasma temperature, at the focus of the intense laser light. The reflected patterns could also be used to diagnose the size of the laser focal spot during a high-intensity interaction when using a regular structure with known spacing

    Role of lattice structure and low temperature resistivity on fast electron beam filamentation in carbon

    Get PDF
    The influence of low temperature (eV to tens-of-eV) electrical resistivity on the onset of the filamentation instability in fast-electron transport is investigated in targets comprising of layers of ordered (diamond) and disordered (vitreous) carbon. It is shown experimentally and numerically that the thickness of the disordered carbon layer influences the degree of filamentation of the fast-electron beam. Strong filamentation is produced if the thickness is of the order of 60 μm or greater, for an electron distribution driven by a sub-picosecond, mid-1020 Wcm-2 laser pulse. It is shown that the position of the vitreous carbon layer relative to the fast-electron source (where the beam current density and background temperature are highest) does not have a strong effect because the resistive filamentation growth rate is high in disordered carbon over a wide range of temperatures up to the Spitzer regime

    Laser-driven X-ray and neutron source development for industrial applications of plasma accelerators

    Get PDF
    Pulsed beams of energetic X-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and X-ray beam generation. Measurements and Monte-Carlo radiation transport simulations show that neutron yield is increased by a factor ~ 2 when a 1mm copper foil is placed behind a 2mm lithium foil, compared to using a 2cm block of lithium only. We explore X-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent Bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte-Carlo code. We also demonstrate the unique capability of laser-driven X-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10ps drive pulse is presented for the first time, demonstrating that features of 200µm size are resolved when projected at high magnification

    The potential role of three-dimensional surface imaging as a tool to evaluate aesthetic outcome after Breast Conserving Therapy (BCT).

    Get PDF
    Purpose To establish whether objective measurements of symmetry of volume and shape using three-dimensional surface imaging (3D-SI) can be used as surrogate markers of aesthetic outcome in patients who have undergone breast conserving therapy (BCT).Methods Women who had undergone unilateral BCT in the preceding 1-6 years were invited to participate. Participants completed a satisfaction questionnaire (BREAST-Q) and underwent 3D-SI. Volume and surface symmetry were measured on the images. Assessment of aesthetic outcome was undertaken by a panel of clinicians. The Kruskal-Wallis test was used to assess the relationship between volume and shape symmetry measurements with the panel score. Spearman's rho correlations were used to assess the relationship between the measurements and patient satisfaction.Results 200 women participated. Median volume symmetry was 87% (IQR 78-93) and shape symmetry was 5.9 mm (IQR 4.2-8.0). The participants were grouped according to panel assessment of aesthetic outcome (poor, fair, good, excellent) and the median volume and shape symmetry was calculated for each group. Volume symmetry significantly differed between the groups. Post hoc pairwise comparisons demonstrated that these differences existed between panel scores of fair versus good and good versus excellent. Median shape symmetry also differed according to patient panel groups with four significant pairwise comparisons between poor versus good, poor versus excellent, fair versus good and fair versus excellent. There was a significant but weak correlation of both volume symmetry and surface asymmetry with BREAST-Q scores (correlation coefficients 0.187 and -0.229, respectively).Conclusion Breast volume and shape symmetry are both associated with panel assessment scores and patient satisfaction. The objective volume and shape symmetry measures were strongly associated with panel assessment scores, such that a 3D-SI tool could replace panel assessment as a faster and more objective method of evaluating aesthetic outcomes

    Ion acceleration and plasma jet formation in ultra-thin foils undergoing expansion and relativistic transparency

    Get PDF
    At sufficiently high laser intensities, the rapid heating to relativistic velocities and resulting decompression of plasma electrons in an ultra-thin target foil can result in the target becoming relativistically transparent to the laser light during the interaction. Ion acceleration in this regime is strongly affected by the transition from an opaque to a relativistically transparent plasma. By spatially resolving the laser-accelerated proton beam at near-normal laser incidence and at an incidence angle of 30°, we identify characteristic features both experimentally and in particle-in-cell simulations which are consistent with the onset of three distinct ion acceleration mechanisms: sheath acceleration; radiation pressure acceleration; and transparency-enhanced acceleration. The latter mechanism occurs late in the interaction and is mediated by the formation of a plasma jet extending into the expanding ion population. The effect of laser incident angle on the plasma jet is explored

    Annular fast electron transport in silicon arising from low-temperature resistivity

    Get PDF
    Fast electron transport in Si, driven by ultra-intense laser pulses, is investigated experimentally and via 3D hybrid-PIC simulations. A transition from a Gaussian-like to an annular fast electron beam profile is demonstrated and explained by resistively generated magnetic fields. The results highlight the potential to completely transform the beam transport pattern by tailoring the resistivity-temperature profile at temperatures as low as a few eV

    Bronchogenic cyst associated with pericardial defect: Case report and review of the literature

    Get PDF
    Partial defect of the pericardium combined with bronchogenic cyst is a very rare congenital anomaly. We describe the case of a 32-year-old man with a partial defect of the left pericardium and a bronchogenic cyst arising from the border of the pericardial defect. The cyst was successfully resected with the harmonic scalpel by three-port videothoracoscopic approach
    corecore