73 research outputs found
PHYSICAL PARAMETER DEPENDENCE OF THE X-RAY GENERATION IN INTENSE LASER – CLUSTER INTERACTION
International audienceStudies on laser – cluster interaction performed on the LUCA facility (French acronym for Ultra Short Tunable Laser, CEA Saclay) allow to observe the production of hard x-rays in the 1 to 5 keV range when rare gas clusters of nanometer sizes are heated by strong optical fields (F > 10^9 V/cm). First complete quantitative measurements of absolute photon emission yields, as well as of charge state distributions of ionic species with inner shell vacancies have been performed as a function of several physical parameters governing the interaction. Our measurements give rise to fundamental results like an optimum heating time and an intensity threshold in the x-ray production. These data provide direct insight into the interaction dynamics and into the heating processes involved
Communes, intercommunalités, quels devenirs ?
Avis du Conseil économique et social sur le rapport présenté par M. Pierre-Jean Rozet au nom de la section des économies régionales et de l\u27aménagement du territoire portant sur l\u27intercommunalité.
(Question dont le Conseil économique et social a été saisi par décision de son bureau en date du 26 octobre 2005 en application de l\u27article 3 de l\u27ordonnance n° 58-1360 du 29 décembre 1958 modifiée portant loi organique relative au Conseil économique et social)
Investigation of slow collisions for (quasi) symmetric heavy systems: what can be extracted from high resolution X-ray spectra
We present a new experiment on (quasi) symmetric collision systems at
low-velocity, namely Ar ions ( a.u.) on gaseous Ar and N
targets, using low- and high-resolution X-ray spectroscopy. Thanks to an
accurate efficiency calibration of the spectrometers, we extract absolute X-ray
emission cross sections combining low-resolution X-ray spectroscopy and a
complete determination of the ion beam - gas jet target overlap. Values with
improved uncertainty are found in agreement with previous results
\cite{Tawara2001}. Resolving the whole He-like Ar Lyman series from
to 10 with our crystal spectrometer enables to determine precisely the
distribution of the electron capture probability and the
preferential level of the selective single-electron capture.
Evaluation of cross sections for this process as well as for the contribution
of multiple-capture is carried out. Their sensitivity to the
-distribution of levels populated by single-electron capture is
clearly demonstrated, providing a stringent benchmark for theories. In
addition, the hardness ratio is extracted and the influence of the decay of the
metastable state on this ratio is discussed
Source X par agrĂ©gats : contrĂ´le et optimisation des paramètres gouvernant lĂnteraction laser de puissance - agrĂ©gats de gaz rare
National audienceLes expĂ©riences que nous avons rĂ©alisĂ©es sur le Laser Ultra Court Accordable du CEA Saclay permettent dĂłbserver l\'Ă©mission de photons X dans la gamme 1-5 keV lors de lĂrradiation dágrĂ©gats de gaz rare (Ar, Kr et Xe comprenant entre 10^3 et 10^6 atomes par agrĂ©gat) avec un laser femtoseconde de puissance (Ipic jusqu\'Ă 10^17 W/cm²). En plus de la distribution des Ă©tats de charge des ions responsables de l\'Ă©mission X, la technique de spectroscopie X que nous utilisons permet de mesurer les taux absolus de photons Ă©mis dans 4Ď€ par impulsion laser en fonction des paramètres gouvernant lĂnteraction dans des conditions contrĂ´lĂ©es. Nous avons dĂ©terminĂ© la sensibilitĂ© des paramètres physiques rĂ©gissant la production du rayonnement X pendant lĂnteraction, ce qui permet dáccĂ©der Ă lĂłptimisation de cette source. Cet article est plus particulièrement dĂ©diĂ© aux rĂ©sultas relatifs Ă l\'Ă©volution du taux d\'X avec l\'Ă©clairement laser, dĂşne part, et avec la durĂ©e de lĂmpulsion laser, dáutre part
Émission X(L) du xénon par interaction laser -agrégats
National audienceNous avons étudié le rayonnement X provenant d'ions fortement multichargés (" 24+) présentant des lacunes en couche L produits lors de l'irradiation d'agrégats de xénon par des impulsions lumineuses issues d'un laser femtoseconde de puissance. Les résultats obtenus lors de la toute dernière campagne d'expériences réalisée auprès du serveur LUCA du SPAM/DRECAM au CEA/Saclay mettent en cause certains travaux antérieurs. Des divergences marquées apparaissent tant au niveau de l'interprétation des spectres X que sur la variation du taux d'émission en fonction de l'éclairement et de la longueur d'onde
Suppression of the thermal hysteresis in magnetocaloric MnAs thin film by highly charged ion bombardment
We present the investigation on the modifications of structural and magnetic
properties of MnAs thin film epitaxially grown on GaAs induced by slow highly
charged ions bombardment under well-controlled conditions. The ion-induced
defects facilitate the nucleation of one phase with respect to the other in the
first-order magneto-structural MnAs transition with a consequent suppression of
thermal hysteresis without any significant perturbation on the other structural
and magnetic properties. In particular, the irradiated film keeps the giant
magnetocaloric effect at room temperature opening new perspective on magnetic
refrigeration technology for everyday use
Dynamique sub-picoseconde de l'interaction laser de puissance – agrégats de gaz rare : émission intense de rayons X et production d'ions multichargés.
National audienceLors de campagnes d'expériences réalisées sur le Laser Ultra Court Accordable du CEA/Saclay, nous avons étudié le rayonnement X, tant qualitativement (spectroscopie et énergie moyenne des photons) que quantitativement (taux absolus et lois d'évolution), émis lors de l'interaction d'un jet effusif d'agrégats de gaz rare (Ar, Kr, Xe comprenant entre 10^4 et 10^6 atomes/agrégat) avec un laser femtoseconde de puissance (éclairement jusqu'à quelques 10^17 W/cm2). Les résultats présentés dans ce manuscrit sont uniquement dédiés aux agrégats d'Ar pour lesquels nous avons observé un rayonnement X issu d'ions fortement multichargés (jusqu'à l'Ar16+) présentant des lacunes en couches K. La technique de spectroscopie X utilisée a permis de déterminer pour la première fois des taux absolus ainsi que les lois d'évolution de l'émission X en fonction de l'ensemble des paramètres gouvernant l'interaction (intensité, polarisation, longueur d'onde et durée du pulse laser aussi bien que taille, densité et numéro atomique des agrégats)
State selective measurements of HCI produced by strong ultrashort laser clusters interaction
International audienceWe have performed studies of keV x-ray production from (Ar)n , (Kr)n and (Xe)n rare gas clusters (with n between 104 and 106 atoms/cluster) submitted to intense (~10^18 W/cm2) infrared (790 nm) laser pulses. We have determined the photon energies and the absolute photon emission yields as a function of several physical parameters governing the interaction : size and atomic number of the clusters, peak intensity of the laser. Up to 10^6 3 keV photons per pulse at a moderate (10^15/cm3) atomic density have been observed. High resolution spectroscopy studies in the case of (Ar)n clusters have also been performed, giving unambiguous evidence of highly charged (up to heliumlike) ions with K vacancies production. The results obtained indicate that X-rays are emitted before cluster explosion on a subpicosecond time scale, and shed some light on the mechanisms involved in the first stage of the production of the nanoplasma induced from each cluster
Magnetic properties changes of MnAs thin films irradiated with highly charged ions
We present the first investigation on the effect of highly charged ion
bombardment on a manganese arsenide thin film. The MnAs films, 150 nm thick,
are irradiated with 90 keV Ne ions with a dose varying from
to ions/cm. The structural and
magnetic properties of the film after irradiation are investigated using
different techniques, namely, X-ray diffraction, magneto-optic Kerr effect and
magnetic force microscope. Preliminary results are presented. From the study of
the lattice spacing, we measure a change on the film structure that depends on
the received dose, similarly to previous studies with other materials.
Investigations on the surface show a strong modification of its magnetic
properties
Diagnostic du plasma de la source d'ions ECR SIMPA par spectroscopie X (collisions d'ions néon hydrogenoïdes avec des agrégats d'argon)
PARIS-BIUSJ-Thèses (751052125) / SudocPARIS-BIUSJ-Physique recherche (751052113) / SudocSudocFranceF
- …