1,725 research outputs found

    Development of a polyimide for use as a temperature and solvent resistant sealant

    Get PDF
    Polyimide developed by the interaction of benzophenone tetracarboxylic dianhydride, polyoxypropylene diamine, and oxydianiline is used for fuel tanks that are exposed to extreme temperatures

    Benchmarking and optimisation of Simulink code using Real-Time Workshop and Embedded Coder for inverter and microgrid control applications

    Get PDF
    When creating software for a new power systems control or protection device, the use of auto-generated C code via MATLAB Simulink Real-Time Workshop and Embedded Coder toolboxes can be a sensible alternative to hand written C code. This approach offers the benefits of a simulation environment, platform independence and robust code. This paper briefly summarises recent experiences with this coding process including the pros and cons of such an approach. Extensive benchmarking activities are presented, together with descriptions of simple (but non-obvious) optimisations made as a result of the benchmarking. Examples include replacement of certain Simulink blocks with seemingly more complex blocks which execute faster. "S functions" are also designed for certain key algorithms. These must be fully "in-lined" to obtain the best speed performance. Together, these optimisations can lead to an increase in execution speed of more than 1.4x in a large piece of auto-generated C code. An example is presented, which carries out Fourier analysis of 3 signals at a common (variable) frequency. The overall speed improvement relative to the baseline is 2.3x, of which more than 1.4x is due to non-obvious improvements resulting from benchmarking activities. Such execution speed improvements allow higher frame rates or larger algorithms within inverters, drives, protection and control applications

    Effects of magnification and visual accommodation on aimpoint estimation in simulated landings with real and virtual image displays

    Get PDF
    Twenty professional pilots observed a computer-generated airport scene during simulated autopilot-coupled night landing approaches and at two points (20 sec and 10 sec before touchdown) judged whether the airplane would undershoot or overshoot the aimpoint. Visual accommodation was continuously measured using an automatic infrared optometer. Experimental variables included approach slope angle, display magnification, visual focus demand (using ophthalmic lenses), and presentation of the display as either a real (direct view) or a virtual (collimated) image. Aimpoint judgments shifted predictably with actual approach slope and display magnification. Both pilot judgments and measured accommodation interacted with focus demand with real-image displays but not with virtual-image displays. With either type of display, measured accommodation lagged far behind focus demand and was reliably less responsive to the virtual images. Pilot judgments shifted dramatically from an overwhelming perceived-overshoot bias 20 sec before touchdown to a reliable undershoot bias 10 sec later

    Increasing security of supply by the use of a local power controller during large system disturbances

    Get PDF
    This paper describes intelligent ways in which distributed generation and local loads can be controlled during large system disturbances, using Local Power Controllers. When distributed generation is available, and a system disturbance is detected early enough, the generation can be dispatched, and its output power can be matched as closely as possible to local microgrid demand levels. Priority-based load shedding can be implemented to aid this process. In this state, the local microgrid supports the wider network by relieving the wider network of the micro-grid load. Should grid performance degrade further, the local microgrid can separate itself from the network and maintain power to the most important local loads, re-synchronising to the grid only after more normal performance is regained. Such an intelligent system would be a suitable for hospitals, data centres, or any other industrial facility where there are critical loads. The paper demonstrates the actions of such Local Power Controllers using laboratory experiments at the 10kVA scale

    The use of real time digital simulation and hardware in the loop to de-risk novel control algorithms

    Get PDF
    Low power demonstrators are commonly used to validate novel control algorithms. However, the response of the demonstrator to network transients and faults is often unexplored. The importance of this work has, in the past, justified facilities such as the T45 Shore Integration Test Facility (SITF) at the Electric Ship Technology Demonstrator (ESTD). This paper presents the use of real time digital simulation and hardware in the loop to de-risk a innovative control algorithm with respect to network transients and faults. A novel feature of the study is the modelling of events at the power electronics level (time steps of circa 2 μs) and the system level (time steps of circa 50 μs)

    Atmospheric nitrogen oxides (NO and NO2) at Dome C, East Antarctica, during the OPALE campaign

    Get PDF
    Mixing ratios of the atmospheric nitrogen oxides NO and NO2 were measured as part of the OPALE (Oxidant Production in Antarctic Lands & Export) campaign at Dome C, East Antarctica (75.1 degrees S, 123.3 degrees E, 3233 m), during December 2011 to January 2012. Profiles of NOx mixing ratios of the lower 100m of the atmosphere confirm that, in contrast to the South Pole, air chemistry at Dome C is strongly influenced by large diurnal cycles in solar irradiance and a sudden collapse of the atmospheric boundary layer in the early evening. Depth profiles of mixing ratios in firn air suggest that the upper snowpack at Dome C holds a significant reservoir of photolytically produced NO2 and is a sink of gas-phase ozone (O-3). First-time observations of bromine oxide (BrO) at Dome C show that mixing ratios of BrO near the ground are low, certainly less than 5 pptv, with higher levels in the free troposphere. Assuming steady state, observed mixing ratios of BrO and RO2 radicals are too low to explain the large NO2 : NO ratios found in ambient air, possibly indicating the existence of an unknown process contributing to the atmospheric chemistry of reactive nitrogen above the Antarctic Plateau. During 2011-2012, NOx mixing ratios and flux were larger than in 2009-2010, consistent with also larger surface O-3 mixing ratios resulting from increased net O-3 production. Large NOx mixing ratios at Dome C arise from a combination of continuous sunlight, shallow mixing height and significant NOx emissions by surface snow (F-NOx). During 23 December 2011-12 January 2012, median F-NOx was twice that during the same period in 20092010 due to significantly larger atmospheric turbulence and a slightly stronger snowpack source. A tripling of F-NOx in December 2011 was largely due to changes in snowpack source strength caused primarily by changes in NO3- concentrations in the snow skin layer, and only to a secondary order by decrease of total column O-3 and associated increase in NO3- photolysis rates. A source of uncertainty in model estimates of F-NOx is the quantum yield of NO3- photolysis in natural snow, which may change over time as the snow ages

    Accelerometer-based physical activity levels differ between week and weekend ways in British preschool children

    Get PDF
    Participation in physical activity (PA) is fundamental to children’s future health. Studies examining the temporal pattern of PA between weekdays and weekends in British preschool children are lacking. Therefore, the aim of this study was to compare PA levels between week and weekend days for UK preschool children, using objective measurements. One hundred and eighty-five preschool children (99 boys, 86 girls, aged 4–5 years), from central England wore a triaxial accelerometer (GENEActiv) for 4 days to determine PA. The time (min) and percentage (%) of time spent in light, moderate and vigorous PA (MVPA) was determined using specific cut-points for counts per minute related to 3–5 year olds. Of the sample, none of the children met the UK recommended 180 min or more of PA per day. A significant difference (P < 0.05) was observed between the amount of time that preschool children spent in sedentary behaviours on weekdays (91.9%) compared to weekend days (96.9%). During weekdays and weekend days, 6.3% and 2.0% of time was spent in MVPA, respectively. Therefore, a substantial proportion of British preschool children’s day is spent in sedentary behaviours, with less MVPA accrued during the weekend. Regular engagement during the weekdays provides opportunities to accrue PA, which may not be present on weekend days.N/

    Preschool and parental influences on physical activity and fundamental movement skills in preschool children from low socio-economic backgrounds: A qualitative study.

    Get PDF
    PA levels of children attending different preschools have been reported as varying greatly, with the characteristics of the preschool influencing a child’s PA level (Pate, Pfeiffer, Trost, Ziegler and Dowda, [2004], Pediatrics 114, 1258-1263). Parents and teachers have been known to overestimate the PA levels that children complete and this may place a decreased importance on encouraging and supporting PA in preschool children (Tucker, [2008], Early Childhood Research Quarterly, 23, 547-558). Settings with greater space and opportunities for outdoor play and PA are required, as a lack of space is a major cause of being overweight for 10-40% of children in developed countries (Blair, Wood and Sallis, [1994], Preventive Medicine, 23, 558-559). Mastery of Fundamental Movement Skills (FMS) is a prerequisite to functioning on a daily basis (Venetsanou and Kambas, [2011], Physical Education and Sport, 9, 81-90); they provide the building blocks for future motor skills and PA. Failure to achieve mastery in these skills could prevent preschool children from participating in PA. Therefore, the aim of this study was to investigate nursery staff and parents’ perceptions of preschool children’s PA, in relation to the environment, facilities, play and barriers to PA. With institutional ethics approval, focus groups were conducted in 4 preschools, with the inclusion of parents and staff of 3-5 year old children (n = 17, parents = 10, staff = 7) from North Warwickshire, England. Thematic analysis (Braun and Clarke, [2006], Qualitative Research in Psychology, 3, 77-101) was used to identify key themes and subthemes from the transcripts. Emergent themes included: outside exercise, outdoor equipment, the responsibility of PA, lack of exercise, modern lifestyles, time, cost, health and safety concerns of staff and staff training. Differences were apparent between preschools when discussing measurement of PA and FMS, PA at home, space in the settings and staff training. The findings suggest that preschools provide good opportunities for PA and FMS, especially for pre-schoolers from low socio-economic backgrounds. However, results also highlighted a need for more extensive training of staff in relation to PA and FMS opportunities. To increase PA and FMS in pre-schoolers, interventions are required which continue with the current levels of PA in preschools, combined with parental involvement to deliver PA; through encouraging indoor and outdoor activities and participating in less sedentary activities in the home environment. Interventions also need to provide staff training to support settings to deliver PA and FMS to preschool children.N/

    Dark Matter Scaling Relations

    Get PDF
    We establish the presence of a dark matter core radius, for the first time in a very large number of spiral galaxies of all luminosities. Contrary to common opinion we find that the sizes of these cores and the " DM core problem" are bigger for more massive spirals. As a result the Burkert profile provides an excellent mass model for dark halos around disk galaxies. Moreover, we find that the spiral dark matter core densities ρ0\rho_{0} and core radii r0r_{0} lie in the same scaling relation ρ0=4.5×102(r0/kpc)2/3Mpc3\rho_{0}=4.5\times 10^-2 (r_{0}/kpc)^{-2/3} M_{\odot}pc^{-3} of dwarf galaxies with core radii upto ten times more smaller.Comment: 4 pages, 4 figures, Accepted for Publication in Apj Let
    corecore