110 research outputs found

    The oxyhaemoglobin dissociation curve is generally left-shifted in COVID-19 patients at admission to hospital, and this is associated with lower mortality

    Get PDF
    Lung damage caused by SARS-Cov-2 virus results in marked arterial hypoxia, accompanied in many cases by hypocapnia. The literature is inconclusive as to whether these conditions induce alteration of the affinity of haemoglobin for oxygen. We studied the oxyhaemoglobin dissociation curves (ODCs) of 517 patients hospitalized with coronavirus disease 2019 (COVID-19) for whom arterial blood gas analysis (BGA) was performed upon hospitalization (i.e., before treatment). With respect to a conventional normal p50 (pO2 at 50% saturation of haemoglobin) of 27 mmHg, 76% had a lower standardized p50 (p50s) and 85% a lower in vivo p50 (p50i). In a 33-patient subgroup with follow-up BGAs after 3, 6, 9, 12, 15 and 18 days' treatment, p50s and p50i exhibited statistically significant differences between baseline values and values recorded at all these time points. The 30-day Kaplan–Meier survival curves of COVID-19 patients stratified by p50i level show a higher probability of survival among patients who at admission had p50 values below 27 mmHg (p = 0.012). Whether the observed alteration of the affinity of haemoglobin for oxygen in COVID-19 patients is a direct or indirect effect of the virus on haemoglobin is unknownS

    Blood eosinophil count as predictor of asthma exacerbation. A meta-analysis

    Get PDF
    This is the peer reviewed version of the following article: Mallah, N., RodrĂ­guez-Segade, S., GonzĂĄlez-Barcala, F.-J., Takkouche, B. (2021). Blood eosinophil count as predictor of asthma exacerbation. A meta-analysis. PAI, 32(3), pp. 465-478, which has been published in final form at https://doi.org/10.1111/pai.13403. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibited.Background Evidence about the association of high blood eosinophil count with asthma exacerbation is inconsistent and unclear. The objective of this meta-analysis was to determine whether elevated blood eosinophil count predicts asthma exacerbation. Methods We searched MEDLINE, EMBASE, and additional databases, without any language restriction. We also checked the reference lists of the included studies and of relevant systematic reviews. The main outcome was the occurrence of asthma exacerbation. We calculated global pooled odds ratios (ORs) and their 95% confidence intervals (CIs) and performed predefined subgroup analyses. We appraised the quality of the studies using Newcastle-Ottawa Scale, examined the heterogeneity between studies, assessed publication bias, and carried out sensitivity analyses. Results Among 1567 retrieved publications, 23 observational studies comprising 155,772 participants met the inclusion criteria. High blood eosinophil count was associated with higher odds of asthma exacerbation [OR: 1.31 (95% CI: 1.16, 1.49)], specifically with asthma-related outpatient visits [OR: 1.46 (95% CI: 1.25, 1.70)] and emergency department visits [OR: 1.63 (95% CI: 1.29, 2.07)]. A significant association was observed starting from an eosinophils’ cutoff value of 200 cells/ÎŒl. The association was observed for cohort studies [OR: 1.30 (95%CI: 1.13, 1.49)], North American studies [OR: 1.43 (95%CI: 1.31, 1.57)], Asian populations [OR: 1.67 (95%CI: 1.34, 2.08)], children [OR: 1.38 (95%CI: 1.22, 1.56)], and studies that adjusted for inhaled corticosteroids therapy [OR: 1.42 (95%CI: 1.28, 1.56)]. Conclusions Blood eosinophil counts ≄ 200 cells/”L are associated with asthma exacerbation. Blood eosinophil count is a modifiable factor that could be addressed in asthma management strategies.S

    The evolution of the ventilatory ratio is a prognostic factor in mechanically ventilated COVID-19 ARDS patients

    Get PDF
    Background: Mortality due to COVID-19 is high, especially in patients requiring mechanical ventilation. The purpose of the study is to investigate associations between mortality and variables measured during the first three days of mechanical ventilation in patients with COVID-19 intubated at ICU admission. Methods: Multicenter, observational, cohort study includes consecutive patients with COVID-19 admitted to 44 Spanish ICUs between February 25 and July 31, 2020, who required intubation at ICU admission and mechanical ventilation for more than three days. We collected demographic and clinical data prior to admission; information about clinical evolution at days 1 and 3 of mechanical ventilation; and outcomes. Results: Of the 2,095 patients with COVID-19 admitted to the ICU, 1,118 (53.3%) were intubated at day 1 and remained under mechanical ventilation at day three. From days 1 to 3, PaO2/FiO2 increased from 115.6 [80.0-171.2] to 180.0 [135.4-227.9] mmHg and the ventilatory ratio from 1.73 [1.33-2.25] to 1.96 [1.61-2.40]. In-hospital mortality was 38.7%. A higher increase between ICU admission and day 3 in the ventilatory ratio (OR 1.04 [CI 1.01-1.07], p = 0.030) and creatinine levels (OR 1.05 [CI 1.01-1.09], p = 0.005) and a lower increase in platelet counts (OR 0.96 [CI 0.93-1.00], p = 0.037) were independently associated with a higher risk of death. No association between mortality and the PaO2/FiO2 variation was observed (OR 0.99 [CI 0.95 to 1.02], p = 0.47). Conclusions: Higher ventilatory ratio and its increase at day 3 is associated with mortality in patients with COVID-19 receiving mechanical ventilation at ICU admission. No association was found in the PaO2/FiO2 variation

    Clustering COVID-19 ARDS patients through the first days of ICU admission. An analysis of the CIBERESUCICOVID Cohort

    Full text link
    Background Acute respiratory distress syndrome (ARDS) can be classified into sub-phenotypes according to different inflammatory/clinical status. Prognostic enrichment was achieved by grouping patients into hypoinflammatory or hyperinflammatory sub-phenotypes, even though the time of analysis may change the classification according to treatment response or disease evolution. We aimed to evaluate when patients can be clustered in more than 1 group, and how they may change the clustering of patients using data of baseline or day 3, and the prognosis of patients according to their evolution by changing or not the cluster.Methods Multicenter, observational prospective, and retrospective study of patients admitted due to ARDS related to COVID-19 infection in Spain. Patients were grouped according to a clustering mixed-type data algorithm (k-prototypes) using continuous and categorical readily available variables at baseline and day 3.Results Of 6205 patients, 3743 (60%) were included in the study. According to silhouette analysis, patients were grouped in two clusters. At baseline, 1402 (37%) patients were included in cluster 1 and 2341(63%) in cluster 2. On day 3, 1557(42%) patients were included in cluster 1 and 2086 (57%) in cluster 2. The patients included in cluster 2 were older and more frequently hypertensive and had a higher prevalence of shock, organ dysfunction, inflammatory biomarkers, and worst respiratory indexes at both time points. The 90-day mortality was higher in cluster 2 at both clustering processes (43.8% [n = 1025] versus 27.3% [n = 383] at baseline, and 49% [n = 1023] versus 20.6% [n = 321] on day 3). Four hundred and fifty-eight (33%) patients clustered in the first group were clustered in the second group on day 3. In contrast, 638 (27%) patients clustered in the second group were clustered in the first group on day 3.Conclusions During the first days, patients can be clustered into two groups and the process of clustering patients may change as they continue to evolve. This means that despite a vast majority of patients remaining in the same cluster, a minority reaching 33% of patients analyzed may be re-categorized into different clusters based on their progress. Such changes can significantly impact their prognosis

    The DUNE far detector vertical drift technology. Technical design report

    Get PDF
    DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals
    • 

    corecore