196 research outputs found

    Contour Approximation with P Systems

    Get PDF
    We model the problem of contour approximation using Hilbert's space lling curve, with a novel type of parallel array rewriting rules. We further use their pattern to introduce a special type of tissue P system, with novel features, among which is controlling their behavior with input. We propose some further developments.Ministerio de Economía, Industria y Competitividad TIN2017-89842-

    Flexibility Assessment in Nuclear Energy dominated Systems with Increased Wind Energy Shares

    Get PDF
    This study analyses the system integration of wind energy in terms of balancing capacities, prices and power plants scheduling. The case study is the French power system, whose characteristics rely on high rates of nuclear power, with some ability to load-follow. The study evaluates several configurations of power plants in 2030 by using a dynamic optimization dispatching model with a highly detailed discrete-time formulation. Results show that operating the French power system with 28 GW of wind power by 2030 seems technically feasible but relies heavily on the capacity of nuclear reactors to follow variations, on storage applications to insure flexibility and on market capacity to allow generators to adapt continuously to the demand. Simulations show that for 11% wind power in the total generation by 2030, balancing the variation is less a matter of installing more flexible capacities, as load factors might decrease and reduce the investors’ interest when prices are relatively low. Balancing becomes more an issue of ramping rates and unit scheduling, power market regulation and real-time market interactions with the day-ahead and intra-day markets.JRC.F.6-Energy Technology Policy Outloo

    High-vacuum-compatible high-power Faraday isolators for gravitational-wave interferometers

    Get PDF
    Faraday isolators play a key role in the operation of large-scale gravitational-wave detectors. Second-generation gravitational-wave interferometers such as the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO) and Advanced Virgo will use high-average-power cw lasers (up to 200 W) requiring specially designed Faraday isolators that are immune to the effects resulting from the laser beam absorption–degraded isolation ratio, thermal lensing, and thermally induced beam steering. In this paper, we present a comprehensive study of Faraday isolators designed specifically for high-performance operation in high-power gravitational-wave interferometers

    Exenatide extended release in patients with type 1 diabetes with and without residual insulin production

    Full text link
    AimsTo test whether a long- acting GLP- 1 receptor agonist would improve glucose control in patients with type 1 diabetes (T1D) and to determine whether the presence of residual beta cell function would affect the response. In addition, we sought to determine whether the drug would affect beta cell function.MethodsWe performed a randomized placebo- controlled trial of exenatide extended release (ER) in participants with T1D with and without detectable levels of C- peptide. Seventy- nine participants were randomized to exenatide ER 2 mcg weekly, or placebo, stratified by the presence or absence of detectable C- peptide levels. The primary outcome was the difference in glycated haemoglobin (HbA1c) levels at 24- weeks. Participants were followed for another 6 months off study drug.ResultsAt week 24, the time of the primary outcome, the least squares (LS) mean HbA1c level was 7.76% (95% confidence interval [CI] 7.42, 8.10) in the exenatide ER group versus 8.0% (95% CI 7.64, 8.35) in the placebo group (P = 0.08). At week 12 the LS mean HbA1c levels were 7.71% (95% CI 7.37, 8.05) in the exenatide ER group versus 8.05% (95% CI 7.7, 8.4) in the placebo group (P = 0.01). The improvement at week 12 was driven mainly by those with detectable levels of C- peptide. Those treated with exenatide ER lost weight at 12 and 24- weeks compared to those treated with placebo (P- <0.001 and P = 0.007). The total insulin dose was lower, but not when corrected for body weight, and was not affected by residual insulin production. Adverse events were more frequent with exenatide ER, but hypoglycaemia was not increased.ConclusionTreatment with exenatide ER may have short- term benefits in some individuals with T1D who are overweight or who have detectable levels of C- peptide, but short- term improvements were not sustained.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/163873/1/dom14121_am.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/163873/2/dom14121.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/163873/3/dom14121-sup-0001-Supinfo.pd

    Poly(3-HydroxyButyrate-co-3-HydroxyValerate) based Inorganic Consolidate for Firwood Preservation

    Get PDF
    The aim of this study was to address one of the major challenges of the conservation state of wooden artifacts or artworks namely, the preservation and restoration of wood surfaces. The factors involved in the deterioration of wood are mainly the external factors such as fire, low temperature and microbiological agents, which induce some degradation processes in wood, identified by discoloration, fragility and unsightly appearance. In this study, biodegradable materials based on poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBHV) and composites based on PHBHV and particles (zinc oxide (ZnO), carbonated hydroxyapatite (CHAp) and its metallic derivatives with silver (AgCHAp) and strontium (SrCHAp) were applied on firwood specimens in order to investigate their consolidation capacity. Colorimetric measurements have confirmed that the chosen treatments did not change the colour of the natural wood. The hardness test revealed that the consolidation system increases the mechanical properties of the samples. The used treatments confer a strong hydrophobic character which prevents exfoliation of the wood samples, as confirmed by the performed water absorption test

    Patient-Reported Outcomes Through 1 Year of an HIV-1 Clinical Trial Evaluating Long-Acting Cabotegravir and Rilpivirine Administered Every 4 or 8 Weeks (ATLAS-2M)

    Get PDF
    BACKGROUND: Advances in HIV-1 therapeutics have led to the development of a range of daily oral treatment regimens, which share similar high efficacy rates. Consequently, more emphasis is being placed upon the individual\u27s experience of treatment and impact on quality of life. The first long-acting injectable antiretroviral therapy for HIV-1 (long-acting cabotegravir + rilpivirine [CAB + RPV LA]) may address challenges associated with oral treatment for HIV-1, such as stigma, pill burden/fatigue, drug-food interactions, and adherence. Patient-reported outcomes (PROs) collected in an HIV-1 clinical trial (ATLAS-2M; NCT03299049) comparing participants\u27 experience with two dosing regimens (every 4 weeks [Q4W] vs. every 8 weeks [Q8W]) of CAB + RPV LA are presented herein. METHODS: PRO endpoints evaluated through 48 weeks of therapy included treatment satisfaction (HIV Treatment Satisfaction Questionnaire [HIVTSQ]), treatment acceptance ( General Acceptance domain of the Chronic Treatment Acceptance [ACCEPT RESULTS: Overall, 1045 participants were randomized to the Q8W (n = 522) and Q4W (n = 523) regimens; 37% (n = 391/1045) had previously received CAB + RPV in ATLAS. For participants without prior CAB + RPV exposure, large increases from baseline were reported in treatment satisfaction in both long-acting arms (HIVTSQ status version), with Q8W dosing statistically significantly favored at Weeks 24 (p = 0.036) and 48 (p = 0.004). Additionally, improvements from baseline were also observed in the General Acceptance domain of the ACCEPT questionnaire in both long-acting arms for participants without prior CAB + RPV exposure; however, no statistically significant difference was observed between arms at either timepoint (Week 24, p = 0.379; Week 48, p = 0.525). Significant improvements (p \u3c 0.001) in the Acceptance of Injection Site Reactions domain of the PIN questionnaire were observed from Week 8 to Weeks 24 and 48 in both arms for participants without prior CAB + RPV exposure. Participants with prior CAB + RPV exposure reported high treatment satisfaction (mean [HIVTSQ status version]: Q8W 62.2/66.0; Q4W 62.0/66.0), treatment acceptance (mean: Q8W 89.3/100; Q4W 91.2/100), and acceptance of injection site reactions (mean [5 = not at all acceptable; 1 = totally acceptable]: Q8W 1.72; Q4W 1.59) at baseline/Week 8 that were maintained over time. Participants without prior CAB + RPV exposure who received Q8W dosing preferred this regimen over oral CAB + RPV (98%, n = 300/306). Among those with prior Q4W exposure, 94% (n = 179/191) preferred Q8W dosing versus Q4W dosing (3%, n = 6/191) or oral CAB + RPV (2%, n = 4/191). CONCLUSIONS: Both long-acting regimens provided high treatment satisfaction and acceptance, irrespective of prior CAB + RPV exposure, with most participants preferring Q8W dosing over both the Q4W regimen and their previous daily oral regimen. The PRO data collected at Week 48 support the therapeutic potential of CAB + RPV LA. FUNDING: ViiV Healthcare and Janssen. TRIAL REGISTRATION: ATLAS-2M: ClinicalTrials.gov NCT03299049, registered October 2, 2017

    The advanced LIGO input optics

    Get PDF
    The advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the strains caused by passing gravitational waves. The input optics play a significant part in allowing these devices to reach such sensitivities. Residing between the pre-stabilized laser and the main interferometer, the input optics subsystem is tasked with preparing the laser beam for interferometry at the sub-attometer level while operating at continuous wave input power levels ranging from 100 mW to 150 W. These extreme operating conditions required every major component to be custom designed. These designs draw heavily on the experience and understanding gained during the operation of Initial LIGO and Enhanced LIGO. In this article, we report on how the components of the input optics were designed to meet their stringent requirements and present measurements showing how well they have lived up to their design

    The Advanced LIGO Input Optics

    Get PDF
    The advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the strains caused by passing gravitational waves. The input optics play a significant part in allowing these devices to reach such sensitivities. Residing between the pre-stabilized laser and the main interferometer, the input optics subsystem is tasked with preparing the laser beam for interferometry at the sub-attometer level while operating at continuous wave input power levels ranging from 100 mW to 150 W. These extreme operating conditions required every major component to be custom designed. These designs draw heavily on the experience and understanding gained during the operation of Initial LIGO and Enhanced LIGO. In this article, we report on how the components of the input optics were designed to meet their stringent requirements and present measurements showing how well they have lived up to their design
    corecore