3,576 research outputs found

    Global Innovation Policy Index

    Get PDF
    Ranks fifty-five nations' strategies to boost innovation capacity: policies on trade, scientific research, information and communications technologies, tax, intellectual property, domestic competition, government procurement, and high-skill immigration

    FARMERS' VEG RISK PERCEPTIONS AND ADOPTION OF VEG CROP INSURANCE

    Get PDF
    Producer survey results are analyzed to determine factors influencing value-enhanced grain (VEG) risk perceptions and VEG crop insurance adoption. VEG production is perceived to be riskier than commodity production. VEG types, input costs, and production problems affect risk perceptions. Factors including previous insurance use impact VEG crop insurance adoption.Risk and Uncertainty,

    Purpose, Meaning, and Exploring Vocation in Honors Education

    Get PDF
    This paper examines the importance of cultivating a sense of vocation in honors education. Through examples of coursework, program initiatives, and advising strategies, authors from across five institutions align the scholarship of vocation with best practices and principles in contemporary honors discourse, defining vocation in the context of higher education and describing how this concept works within honors curricula to enrich student experience and cultivate individual understandings of purpose. By focusing on critical reflection processes, Ignatian pedagogy, and theories of moral development and reasoning, the authors offer different models to advance the thesis that honors educators can and should address personal fulfillment in addition to intellectual talent, and they posit vocational exploration and discernment as tools for extending and deepening their students’ personal sense of meaning in local and global communities

    A Small Claims Court for Pennsylvania

    Get PDF

    SNTF immunostaining reveals previously undetected axonal pathology in traumatic brain injury

    Get PDF
    Diffuse axonal injury (DAI) is a common feature of severe traumatic brain injury (TBI) and may also be a predominant pathology in mild TBI or “concussion”. The rapid deformation of white matter at the instant of trauma can lead to mechanical failure and calcium-dependent proteolysis of the axonal cytoskeleton in association with axonal transport interruption. Recently, a proteolytic fragment of alpha-II spectrin, “SNTF”, was detected in serum acutely following mild TBI in patients and was prognostic for poor clinical outcome. However, direct evidence that this fragment is a marker of DAI has yet to be demonstrated in either humans following TBI or in models of mild TBI. Here, we used immunohistochemistry (IHC) to examine for SNTF in brain tissue following both severe and mild TBI. Human severe TBI cases (survival <7d; n = 18) were compared to age-matched controls (n = 16) from the Glasgow TBI archive. We also examined brains from an established model of mild TBI at 6, 48 and 72 h post-injury versus shams. IHC specific for SNTF was compared to that of amyloid precursor protein (APP), the current standard for DAI diagnosis, and other known markers of axonal pathology including non-phosphorylated neurofilament-H (SMI-32), neurofilament-68 (NF-68) and compacted neurofilament-medium (RMO-14) using double and triple immunofluorescent labeling. Supporting its use as a biomarker of DAI, SNTF immunoreactive axons were observed at all time points following both human severe TBI and in the model of mild TBI. Interestingly, SNTF revealed a subpopulation of degenerating axons, undetected by the gold-standard marker of transport interruption, APP. While there was greater axonal co-localization between SNTF and APP after severe TBI in humans, a subset of SNTF positive axons displayed no APP accumulation. Notably, some co-localization was observed between SNTF and the less abundant neurofilament subtype markers. Other SNTF positive axons, however, did not co-localize with any other markers. Similarly, RMO-14 and NF-68 positive axonal pathology existed independent of SNTF and APP. These data demonstrate that multiple pathological axonal phenotypes exist post-TBI and provide insight into a more comprehensive approach to the neuropathological assessment of DAI

    Removal of terrestrial DOC in aquatic ecosystems of a temperate river network

    Get PDF
    Surface waters play a potentially important role in the global carbon balance. Dissolved organic carbon (DOC) fluxes are a major transfer of terrestrial carbon to river systems, and the fate of DOC in aquatic systems is poorly constrained. We used a unique combination of spatially distributed sampling of three DOC fractions throughout a river network and modeling to quantify the net removal of terrestrial DOC during a summer base flow period. We found that aquatic reactivity of terrestrial DOC leading to net loss is low, closer to conservative chloride than to reactive nitrogen. Net removal occurred mainly from the hydrophobic organic acid fraction, while hydrophilic and transphilic acids showed no net change, indicating that partitioning of bulk DOC into different fractions is critical for understanding terrestrial DOC removal. These findings suggest that river systems may have only a modest ability to alter the amounts of terrestrial DOC delivered to coastal zones

    Erenumab in chronic migraine: Patient-reported outcomes in a randomized double-blind study.

    Get PDF
    OBJECTIVE: To determine the effect of erenumab, a human monoclonal antibody targeting the calcitonin gene-related peptide receptor, on health-related quality of life (HRQoL), headache impact, and disability in patients with chronic migraine (CM). METHODS: In this double-blind, placebo-controlled study, 667 adults with CM were randomized (3:2:2) to placebo or erenumab (70 or 140 mg monthly). Exploratory endpoints included migraine-specific HRQoL (Migraine-Specific Quality-of-Life Questionnaire [MSQ]), headache impact (Headache Impact Test-6 [HIT-6]), migraine-related disability (Migraine Disability Assessment [MIDAS] test), and pain interference (Patient-Reported Outcomes Measurement Information System [PROMIS] Pain Interference Scale short form 6b). RESULTS: Improvements were observed for all endpoints in both erenumab groups at month 3, with greater changes relative to placebo observed at month 1 for many outcomes. All 3 MSQ domains were improved from baseline with treatment differences for both doses exceeding minimally important differences established for MSQ-role function-restrictive (≥3.2) and MSQ-emotional functioning (≥7.5) and for MSQ-role function-preventive (≥4.5) for erenumab 140 mg. Changes from baseline in HIT-6 scores at month 3 were -5.6 for both doses vs -3.1 for placebo. MIDAS scores at month 3 improved by -19.4 days for 70 mg and -19.8 days for 140 mg vs -7.5 days for placebo. Individual-level minimally important difference was achieved by larger proportions of erenumab-treated participants than placebo for all MSQ domains and HIT-6. Lower proportions of erenumab-treated participants had MIDAS scores of severe (≥21) or very severe (≥41) or PROMIS scores ≥60 at month 3. CONCLUSIONS: Erenumab-treated patients with CM experienced clinically relevant improvements across a broad range of patient-reported outcomes. CLINICALTRIALSGOV IDENTIFIER: NCT02066415. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that for patients with CM, erenumab treatment improves HRQoL, headache impact, and disability

    Reproducibility of body volume assessments in survival clothing in fixed and portable scanning systems.

    Get PDF
    The recent development of portable 3D scanning systems for industries such as animation and museum artefact digitisation have considerable potential for applications involving human body measurement. However, this requires a system for validation of measurements against a criterion, which this study aimed to provide. Forty four adult males were scanned in duplicate in both a fixed Hamamatsu and portable Artec L scanning systems in two postures and two different clothing assemblages. Following inspection of all scans, complete data for duplicate scans of 38 participants were available for the study. Both scanners demonstrated good precision, however significant differences in body volume prevailed for both egress and scanner postures in form-fitting clothing and the scanner posture in survival suit scans, with the Hamamatsu providing greater volumes than the Artec system (by 2.7, 2.8 and 2.1 litres respectively). Regression analysis indicated the results from the portable scanner explained between 96 and 98% of the variability in the results from the fixed scanner. The biases in body volume probably relate to different software approaches to its calculation, and a possible interaction with posture and clothing. Validation of the Artec against the Hamamatsu system provides valuable information for its use in field and industrial settings
    corecore