1,139 research outputs found

    An electrochromic ionic liquid: design, characterisation and performance in a solid state platform

    Get PDF
    This work describes the synthesis and characteristics of a novel electrochromic ionic liquid (IL) based on a phosphonium core tethered to a viologen moiety. When integrated into a solid-state electrochromic platform, the viologen modified IL behaved as both the electrolyte and the electrochromic material. Platform fabrication was achieved through in situ photo-polymerisation and encapsulation of this novel IL within a hybrid sol-gel. Important parameters of the platform performance, including its coloration efficiency, switching kinetics and optical properties were characterised using UV/Vis spectroscopy and cyclic voltammetry in tandem. The electrochromic platform exhibits a coloration efficiency of 10.72 cm2C-1, and a varied optical output as a function of the incident current. Despite the rather viscous nature of the material, the platform exhibited approximately two orders of magnitude faster switching kinetics (221 seconds to reach 95 % absorbance) when compared to previously reported electrochromic ILs (18,000 seconds)

    Diagnosis and management of pseudohypoparathyroidism and related disorders: first international Consensus Statement

    Get PDF
    This Consensus Statement covers recommendations for the diagnosis and management of patients with pseudohypoparathyroidism (PHP) and related disorders, which comprise metabolic disorders characterized by physical findings that variably include short bones, short stature, a stocky build, early-onset obesity and ectopic ossifications, as well as endocrine defects that often include resistance to parathyroid hormone (PTH) and TSH. The presentation and severity of PHP and its related disorders vary between affected individuals with considerable clinical and molecular overlap between the different types. A specific diagnosis is often delayed owing to lack of recognition of the syndrome and associated features. The participants in this Consensus Statement agreed that the diagnosis of PHP should be based on major criteria, including resistance to PTH, ectopic ossifications, brachydactyly and early-onset obesity. The clinical and laboratory diagnosis should be confirmed by a molecular genetic analysis. Patients should be screened at diagnosis and during follow-up for specific features, such as PTH resistance, TSH resistance, growth hormone deficiency, hypogonadism, skeletal deformities, oral health, weight gain, glucose intolerance or type 2 diabetes mellitus, and hypertension, as well as subcutaneous and/or deeper ectopic ossifications and neurocognitive impairment. Overall, a coordinated and multidisciplinary approach from infancy through adulthood, including a transition programme, should help us to improve the care of patients affected by these disorders

    Self-love and sociability: the ‘rudiments of commerce’ in the state of nature

    Get PDF
    Istvan Hont’s classic work on the theoretical links between the seventeenth-century natural jurists Hugo Grotius and Samuel Pufendorf and the eighteenth-century Scottish political economists remains a popular trope among intellectual and economic historians of various stamps. Despite this, a common criticism levelled at Hont remains his relative lack of engagement with the relationship between religion and economics in the early modern period. This paper challenges this aspect of Hont’s narrative by drawing attention to an alternative, albeit complementary, assessment of the natural jurisprudential heritage of eighteenth-century British political economy. Specifically, the article attempts to map on to Hont’s thesis the Christian Stoic interpretation of Grotius and Pufendorf which has gained greater currency in recent years. In doing so, the paper argues that Grotius and Pufendorf’s contributions to the ‘unsocial sociability’ debate do not necessarily lead directly to the Scottish school of political economists, as is commonly assumed. Instead, it contends that a reconsideration of Grotius and Pufendorf as neo-Stoic theorists, particularly via scrutiny of their respective adaptations of the traditional Stoic theory of oikeiosis, steers us towards the heart of the early English ‘clerical’ Enlightenment

    Abstracts of presentations on selected topics at the XIVth international plant protection congress (IPPC) July 25-30, 1999

    Get PDF

    Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker

    Get PDF
    During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m2^{2} of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 1015^{15} neq_{eq}/cm2^{2}. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker

    Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation

    Get PDF
    The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5–7.5×1034^{34} cm2^{-2}s1^{-1}. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000–4000 fb-1 of proton-proton collisions at a center-of-mass energy of 13–14 TeV. To cope with these challenging environmental conditions, the strip tracker of the CMS experiment will be upgraded using modules with two closely-spaced silicon sensors to provide information to include tracking in the Level-1 trigger selection. This paper describes the performance, in a test beam experiment, of the first prototype module based on the final version of the CMS Binary Chip front-end ASIC before and after the module was irradiated with neutrons. Results demonstrate that the prototype module satisfies the requirements, providing efficient tracking information, after being irradiated with a total fluence comparable to the one expected through the lifetime of the experiment

    Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade

    Get PDF
    The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam

    Doxycycline versus prednisolone as an initial treatment strategy for bullous pemphigoid: a pragmatic non-inferiority randomised controlled trial

    Get PDF
    Background: Bullous pemphigoid (BP) is a blistering skin disorder with increased mortality. We tested whether a strategy of starting treatment with doxycycline conveys acceptable short-term blister control whilst conferring long-term safety advantages over starting treatment with oral corticosteroids. Methods: Pragmatic multi-centre parallel-group randomised controlled trial of adults with BP (≥3 blisters ≥2 sites and linear basement membrane IgG/C3) plus economic evaluation. Participants were randomised to doxycycline (200 mg/day) or prednisolone (0·5 mg/kg/day). Localised adjuvant potent topical corticosteroids (<30 g/week) was permitted weeks 1-3. The non-inferiority primary effectiveness outcome was the proportion of participants with ≤3 blisters at 6 weeks. We assumed that doxycycline would be 25% less effective than corticosteroids with a 37% acceptable margin of noninferiority. The primary safety outcome was the proportion with severe, life-threatening or fatal treatment-related adverse events by 52 weeks. Analysis used a regression model adjusting for baseline disease severity, age and Karnofsky score, with missing data imputed. Results: 132 patients were randomised to doxycycline and 121 to prednisolone from 54 UK and 7 German dermatology centres. Mean age was 77·7 years and 68.4% had moderate to severe baseline disease. For those starting doxycycline, 83/112 (74·1%) had ≤3 blisters at 6 weeks compared with 92/101 (91·1%) for prednisolone, a difference of 18·6% favouring prednisolone (upper limit of 90% CI, 26·1%, within the predefined 37% margin). Related severe, life-threatening and fatal events at 52 weeks were 18·5% for those starting doxycycline and 36·6% for prednisolone (mITT analysis), an adjusted difference of 19·0% (95% CI, 7·9%, 30·1%, p=0·001). Conclusions: A strategy of starting BP patients on doxycycline is non-inferior to standard treatment with oral prednisolone for short-term blister control and significantly safer long-term

    Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

    Get PDF
    The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip

    A checklist for health research priority setting: nine common themes of good practice

    Get PDF
    Health research priority setting processes assist researchers and policymakers in effectively targeting research that has the greatest potential public health benefit. Many different approaches to health research prioritization exist, but there is no agreement on what might constitute best practice. Moreover, because of the many different contexts for which priorities can be set, attempting to produce one best practice is in fact not appropriate, as the optimal approach varies per exercise. Therefore, following a literature review and an analysis of health research priority setting exercises that were organized or coordinated by the World Health Organization since 2005, we propose a checklist for health research priority setting that allows for informed choices on different approaches and outlines nine common themes of good practice. It is intended to provide generic assistance for planning health research prioritization processes. The checklist explains what needs to be clarified in order to establish the context for which priorities are set; it reviews available approaches to health research priority setting; it offers discussions on stakeholder participation and information gathering; it sets out options for use of criteria and different methods for deciding upon priorities; and it emphasizes the importance of well-planned implementation, evaluation and transparency
    corecore