    Development of a Mass Flowmeter based on the Coriolis Acceleration for Liquid, Supercritical and Superfluid Helium

    Get PDF
    Beginning in the 1980's, Coriolis meters have gained generalised acceptance in liquid applications with a worldwide installed base of over 300,000 units. To meet the demands of cryogenic applications below 20 K, off-the-shelf Coriolis meters have been used, with minor design modifications and operational changes. The meters were originally calibrated on water and tested on liquid helium at 4.5 K, supercritical helium around 5 K and superfluid helium below 2 K. The meters maintain their intrinsic robustness and accuracy of better than 1% of measured value; accuracy is independent of density and temperature

    A large dynamic range radiation-tolerant analog memory in a quarter- micron CMOS technology

    Get PDF
    An analog memory prototype containing 8*128 cells has been designed in a commercial quarter-micron CMOS process. The aim of this work is to investigate the possibility of designing large dynamic range mixed-mode switched capacitor circuits for high-energy physics (HEP) applications in deep submicron CMOS technologies. Special layout techniques have been used to make the circuit radiation tolerant. The memory cells employ gate-oxide capacitors for storage, permitting a very high density. A voltage write-voltage read architecture has been chosen to minimize the sensitivity to absolute capacitor values. The measured input voltage range is 2.3 V (the power supply voltage V/sub DD/ is equal to 2.5 V), with a linearity of almost 8 bits over 2 V. The dynamic range is more than 11 bits. The pedestal variation is +or-0.5 mV peak-to-peak. The noise measured, which is dominated by the noise of the measurement setup, is around 0.8 mV rms. The characteristics of the memory have been measured before irradiation and after 100 kGy (SiO/sub 2/), and they do not degrade after irradiation. (15 refs)

    Recent Developments and Qualification of Cryogenic Helium Flow Meters

    Get PDF
    Flow measurement of cryogenic fluids is a useful diagnostic tool not only to assess thermal performance of superconducting devices and related components but also for early diagnosis of faulty components/systems and to assure the correct sharing of cryogenic power. It is mainly performed on the recovery at room temperature of vapor from liquid boil-off due to lack of commercially available robust and precise cryogenic mass flow meters. When high-accuracy or fast-time response is needed, or individual gas recovery at room temperature is not available, it is necessary to measure directly the fluid feed at cryogenic temperature. The results of extensive testing of industrially available and in-house developed flowmeters outlining characteristics and advantages of each measuring method are presented

    Beam test results of the irradiated Silicon Drift Detector for ALICE

    Full text link
    The Silicon Drift Detectors will equip two of the six cylindrical layers of high precision position sensitive detectors in the ITS of the ALICE experiment at LHC. In this paper we report the beam test results of a SDD irradiated with 1 GeV electrons. The aim of this test was to verify the radiation tolerance of the device under an electron fluence equivalent to twice particle fluence expected during 10 years of ALICE operation.Comment: 6 pages,6 figures, to appear in the proceedings of International Workshop In high Multiplicity Environments (TIME'05), 3-7 October 2005, Zurich,Switzerlan

    Front end electronics for pixel detector of the PANDA MVD

    Get PDF
    ToPix 2.0 is a prototype in a CMOS 0.13 ¹m technology of the front-end chip for the hybrid pixel sensors that will equip the Micro-Vertex Detector of the PANDA experiment at GSI. The Time over Threshold (ToT) approach has been employed to provide a high charge dynamic range (up to 100 fC) with a low power dissipation (15 ¹W/cell). In an area of 100¹m£100¹m each cell incorporates the analog and digital electronics necessary to amplify the detector signal and to digitize the time and charge information. The ASIC includes 320 pixel readout cells organized in four columns and a simplified version of the end of column readout

    "CMAD", a Full Custom ASIC, for the Upgrade of COMPASS RICH-1

    Get PDF
    An 8 channel, full-custom ASIC prototype, named ”CMAD”, designed for the readout of the RICH-I detector system of the COMPASS experiment at CERN is presented. The task of the chip is amplifying the signals coming from fast multi-anode photomultipliers and comparing them against a threshold adjustable on-chip on a channel by channel basis. CMAD, developed using a 350nm commercial CMOS technology, occupies an area of 4.7x3.2mm2 and consumes 26mW/Ch power from a 3.3 V single source

    A low-noise CMOS front-end for TOF-PET

    Get PDF
    An analogue CMOS front-end for triggering and amplification of signals produced by a silicon photomultiplier (SiPM) coupled to a LYSO scintillator is proposed. The solution is intended for time-of-flight measurement in compact Positron Emission Tomography (TOF-PET) medical imaging equipments where excellent timing resolution is required (approximate to 100 ps). A CMOS 0.13 mu m technology was used to implement such front end, and the design includes preamplification, shaping, baseline holder and biasing circuitry, for a total silicon area of 500x90 mu m. Waveform sampling and time-over-threshold (ToT) techniques are under study and the front-end provides fast and shaped outputs for time and energy measurements. Post layout simulation results show that, for the trigger of a single photoelectron, the time jitter due to the pre-amplifier noise can be as low as 15 ps (FWHM), for a photodetector with a total capacitance of 70 pF. The very low input impedance of the pre-amplifier (approximate to 5 Omega) allows 1.8 ns of peaking time, at the cost of 10 mW of power consumption

    CARIOCA: a fast binary front-end implemented in 0.25μ0.25\mu CMOS using a Novel current-mode technique for the LHCb muon detector

    Get PDF
    The CARIOCA front-end is an amplifier discriminator chip, using 0.25mm CMOS technology, developed with a very fast and low noise preamplifier. This prototype was designed to have input impedance below 10W. Measurements showed a peaking time of 14ns and noise of 450e- at zero input capacitance, with a noise slope of 37.4 e-/pF. The sensitivity of 8mV/fC remains almost unchanged up to a detector capacitance of 120pF