784 research outputs found

    Comparing Methods to Extract the Knowledge from Neural Networks

    Get PDF
    Neural networks (NN) have been shown to be accurate classifiers in many domains. Unfortunately, the lack of NN’s explanatory capability of knowledge learned has somewhat limited their application. A stream of research has therefore developed focusing on knowledge extraction from within neural networks. The literature, unfortunately, lacks consensus on how best to extract knowledge from help neural networks. Additionally, there is a lack of empirical studies that compare existing algorithms on relevant performance measures. Therefore, this study attempts to help fill this gap by comparing two different approaches to extracting IF-THEN rules from feedforward NN. The results show a significant difference in the performance of the two algorithms depending on the structure of the dataset utilized

    Patient-reported outcomes in randomized clinical trials of systemic therapy for advanced soft tissue sarcomas in adults:A systematic review

    Get PDF
    Background: This systematic review evaluates reporting of patient-reported outcomes (PROs) within randomized clinical trials (RCTs) for advanced soft tissue sarcoma (STS) patients. Methods: A systematic literature search from January 2000 – August 2022 was conducted for phase II/III RCTs evaluating systemic treatments in adult patients with advanced STS. Quality of PRO reporting was assessed using the CONSORT PRO extension. Results: Out of 7294 abstracts, 59 articles were included; comprising 43 RCTs. Only 15 RCTs (35%) included PROs, none as primary endpoints. Only 10 of these RCTs reported PROs, either in the primary (6/10) or secondary publication (1/10) or in both (3/10), with a median time interval of 23 months. The median CONSORT PRO adherence score was 5.5/14, with higher scores in publications focusing exclusively on PROs. Conclusion: These results highlight the need for improved and more consistent PRO reporting to inform patient care in the setting of advanced STS.</p

    Canadian Hydrogen Intensity Mapping Experiment (CHIME) Pathfinder

    Full text link
    A pathfinder version of CHIME (the Canadian Hydrogen Intensity Mapping Experiment) is currently being commissioned at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, BC. The instrument is a hybrid cylindrical interferometer designed to measure the large scale neutral hydrogen power spectrum across the redshift range 0.8 to 2.5. The power spectrum will be used to measure the baryon acoustic oscillation (BAO) scale across this poorly probed redshift range where dark energy becomes a significant contributor to the evolution of the Universe. The instrument revives the cylinder design in radio astronomy with a wide field survey as a primary goal. Modern low-noise amplifiers and digital processing remove the necessity for the analog beamforming that characterized previous designs. The Pathfinder consists of two cylinders 37\,m long by 20\,m wide oriented north-south for a total collecting area of 1,500 square meters. The cylinders are stationary with no moving parts, and form a transit instrument with an instantaneous field of view of \sim100\,degrees by 1-2\,degrees. Each CHIME Pathfinder cylinder has a feedline with 64 dual polarization feeds placed every \sim30\,cm which Nyquist sample the north-south sky over much of the frequency band. The signals from each dual-polarization feed are independently amplified, filtered to 400-800\,MHz, and directly sampled at 800\,MSps using 8 bits. The correlator is an FX design, where the Fourier transform channelization is performed in FPGAs, which are interfaced to a set of GPUs that compute the correlation matrix. The CHIME Pathfinder is a 1/10th scale prototype version of CHIME and is designed to detect the BAO feature and constrain the distance-redshift relation.Comment: 20 pages, 12 figures. submitted to Proc. SPIE, Astronomical Telescopes + Instrumentation (2014

    The Grizzly, September 25, 1981

    Get PDF
    Greaseband Tonight • Campus Welcome • Fridge Fee Unfrozen • Deutsch und Deutschland Heute: German Professor Co-authors Text • Public Speaking Exemption Exam • Books Sought by Ursinus Friends • Red Cross Bloodmobile at Helfferich Hall • Career Planning and Placement Office • Dessert Held in Union • Fast Food Service Losing Convenience • ProTheatre: Canterbury Tales Presented • Transplanted Texan: Nobody Expects the Moral Majority • School Bands Looking for Musicians • WRUC: Back on the Air? • First Coffeehouse Sparkles With Talent • Late Mail for Off-Campus Houses • [Reprinted Articles About the Greaseband] • Bear\u27s Booters Kick Off Season • Business as Usual for Cross-Country • Bears Drop 10-3 Decision to Western Maryland • Davis Leads Hockey Over Widenerhttps://digitalcommons.ursinus.edu/grizzlynews/1061/thumbnail.jp

    PATRIC, the bacterial bioinformatics database and analysis resource

    Get PDF
    The Pathosystems Resource Integration Center (PATRIC) is the all-bacterial Bioinformatics Resource Center (BRC) (http://www.patricbrc.org). A joint effort by two of the original National Institute of Allergy and Infectious Diseases-funded BRCs, PATRIC provides researchers with an online resource that stores and integrates a variety of data types [e.g. genomics, transcriptomics, protein-protein interactions (PPIs), three-dimensional protein structures and sequence typing data] and associated metadata. Datatypes are summarized for individual genomes and across taxonomic levels. All genomes in PATRIC, currently more than 10 000, are consistently annotated using RAST, the Rapid Annotations using Subsystems Technology. Summaries of different data types are also provided for individual genes, where comparisons of different annotations are available, and also include available transcriptomic data. PATRIC provides a variety of ways for researchers to find data of interest and a private workspace where they can store both genomic and gene associations, and their own private data. Both private and public data can be analyzed together using a suite of tools to perform comparative genomic or transcriptomic analysis. PATRIC also includes integrated information related to disease and PPIs. All the data and integrated analysis and visualization tools are freely available. This manuscript describes updates to the PATRIC since its initial report in the 2007 NAR Database Issu

    Search for R-Parity Violating Decays of Scalar Fermions at LEP

    Full text link
    A search for pair-produced scalar fermions under the assumption that R-parity is not conserved has been performed using data collected with the OPAL detector at LEP. The data samples analysed correspond to an integrated luminosity of about 610 pb-1 collected at centre-of-mass energies of sqrt(s) 189-209 GeV. An important consequence of R-parity violation is that the lightest supersymmetric particle is expected to be unstable. Searches of R-parity violating decays of charged sleptons, sneutrinos and squarks have been performed under the assumptions that the lightest supersymmetric particle decays promptly and that only one of the R-parity violating couplings is dominant for each of the decay modes considered. Such processes would yield final states consisting of leptons, jets, or both with or without missing energy. No significant single-like excess of events has been observed with respect to the Standard Model expectations. Limits on the production cross- section of scalar fermions in R-parity violating scenarios are obtained. Constraints on the supersymmetric particle masses are also presented in an R-parity violating framework analogous to the Constrained Minimal Supersymmetric Standard Model.Comment: 51 pages, 24 figures, Submitted to Eur. Phys. J.

    Bose-Einstein Correlations of Three Charged Pions in Hadronic Z^0 Decays

    Get PDF
    Bose-Einstein Correlations (BEC) of three identical charged pions were studied in 4 x 10^6 hadronic Z^0 decays recorded with the OPAL detector at LEP. The genuine three-pion correlations, corrected for the Coulomb effect, were separated from the known two-pion correlations by a new subtraction procedure. A significant genuine three-pion BEC enhancement near threshold was observed having an emitter source radius of r_3 = 0.580 +/- 0.004 (stat.) +/- 0.029 (syst.) fm and a strength of \lambda_3 = 0.504 +/- 0.010 (stat.) +/- 0.041 (syst.). The Coulomb correction was found to increase the \lambda_3 value by \~9% and to reduce r_3 by ~6%. The measured \lambda_3 corresponds to a value of 0.707 +/- 0.014 (stat.) +/- 0.078 (syst.) when one takes into account the three-pion sample purity. A relation between the two-pion and the three-pion source parameters is discussed.Comment: 19 pages, LaTeX, 5 eps figures included, accepted by Eur. Phys. J.

    Search for the Standard Model Higgs Boson with the OPAL Detector at LEP

    Full text link
    This paper summarises the search for the Standard Model Higgs boson in e+e- collisions at centre-of-mass energies up to 209 GeV performed by the OPAL Collaboration at LEP. The consistency of the data with the background hypothesis and various Higgs boson mass hypotheses is examined. No indication of a signal is found in the data and a lower bound of 112.7GeV/C^2 is obtained on the mass of the Standard Model Higgs boson at the 95% CL.Comment: 51 pages, 21 figure
    corecore