39 research outputs found

    Biosensor Applications in the Field of Antibiotic Research—A Review of Recent Developments

    Get PDF
    Antibacterials are among of the most important medications used in health care. However, their efficacy is increasingly impeded by a tremendous and globally spread bacterial resistance phenomenon. This bacterial resistance is accelerated by inadequate application of antibacterial drugs in humans, the widespread veterinary use of antibacterials, and antibacterial occurrence in the environment and food. Further, there is a lack of development of innovative novel drugs. Therefore, the search for novel antibacterials has to be intensified and the spread of antibacterials in the environment has to be restricted. Due to the fundamental progress in biosensor development and promising applications in the antibiotic field, this review gives for the first time an overview on the use and prospects of biosensor applications in that area. A number of reports have applied biosensors of different design and techniques to search for antibacterials in environmental and foodstuff matrices. These studies are discussed with respect to the analytical values and compared to conventional techniques. Furthermore, biosensor applications to elucidate the mode of action of antimicrobial drugs in vitro have been described. These studies were critically introduced referring to the informational value of those simulations. In summary, biosensors will be illustrated as an innovative and promising, although not yet comprehensively applied, technique in the antibacterial field

    Development of a rapid low cost fluorescent biosensor for the detection of food contaminants

    Get PDF
    A prototype fluorescent based biosensor has been developed for the antibody based detection of food related contaminants. Its performance was characterised and showed a typical antibody binding signal of 200-2000. mV, a short term noise of 9.1. mV, and baseline slope of -0.016. mV/s over 4. h. Bulk signal detection repeatability (n=23) and reproducibility (n=3) were less than 2.4%CV. The biosensor detection unit was evaluated using two food related model systems proving its ability to monitor both binding using commercial products and inhibition through the development of an assay. This assay development potential was evaluated by observing the biosensor's performance whilst appraising several labelled antibody and glass slide configurations. The molecular interaction between biotin and an anti-biotin antibody was shown to be inhibited by 41% due to the presence of biotin in a sample. A food toxin (domoic acid) calibration curve was produced, with %CVs ranging from 2.7 to 7.8%, and a midpoint of approximately 17. ng/ml with further optimisation possible. The ultimate aim of this study was to demonstrate the working principles of this innovative biosensor as a potential portable tool with the opportunity of interchangeable assays. The biosensor design is applicable for the requirements of routine food contaminant analysis, with respect to performance, functionality and cost.</p

    Biosensors for the Detection of Antibiotics in Poultry Industry—A Review

    No full text
    Antibiotic resistance is emerging as a potential threat in the next decades. This is a global phenomenon whereby globalization is acting as a catalyst. Presently, the most common techniques used for the detection of antibiotics are biosensors, ELISA and liquid chromatography—mass spectrometry. Each of these techniques has its benefits as well as drawbacks. This review aims to evaluate different biosensing techniques and their working principles in order to accurately, quickly and practically detect antibiotics in chicken muscle and blood serum. The review is divided into three main sections, namely: a biosensors overview, a section on biosensor recognition and a section on biosensor transducing elements. The first segment provides a detailed overview on the different techniques available and their respective advantages and disadvantages. The second section consists of an evaluation of several analyte systems and their mechanisms. The last section of this review studies the working principles of biosensing transducing elements, focusing mainly on surface plasmon resonance (SPR) technology and its applications in industries

    Model membrane approaches to determine the role of calcium for the antimicrobial activity of friulimicin

    Full text link
    International audienceFriulimicin is a cyclic lipopeptide antibiotic, currently in clinical development, that possesses excellent activity against Gram-positive bacteria, including multiresistant strains. A recent study on the mode of action of friulimicin reported on the interference with bacterial cell wall biosynthesis via a calcium-dependent complexing of the bactoprenol phosphate carrier C-P. The calcium dependency of this non-common targeted activity remains to be elucidated. In the present model membrane approach, the role of calcium for friulimicin targeting to C-P was investigated by biosensor-based detection of binding affinities. The findings were supplemented by atomic force microscopy (AFM) and circular dichroism (CD) spectroscopy. Comparing the calcium salt of friulimicin with the calcium-free peptide, calcium appeared to be essential for friulimicin interaction with 1,2-dioleoyl--glycero-3-phosphocholine (DOPC) model membranes. The binding affinity was even higher in the presence of 0.1 mol% C-P (0.21μM vs. 1.22μM), confirming the targeted mode of action. Binding experiments with supplemented calcium salts suggest (i) the phosphate group as the essential moiety of C-P, referring to a bridging function of calcium between the negatively charged friulimicin and C-P, and (ii) a structural effect of calcium shifting the peptide into a suitable binding conformation (CD spectra). AFM images confirmed that calcium has no, or only a minor, effect on the aggregate formation of friulimicin. These data shed new light on the mechanisms of antibacterial activity of friulimicin

    Analysis of membrane interactions of antibiotic peptides using ITC and biosensor measurements

    Full text link
    International audienceThe interaction of the lantibiotic gallidermin and the glycopeptide antibiotic vancomycin with bacterial membranes was simulated using mass sensitive biosensors and isothermal titration calorimetry (ITC). Both peptides interfere with cell wall biosynthesis by targeting the cell wall precursor lipid II, but differ clearly in their antibiotic activity against individual bacterial strains. We determined binding affinities of vancomycin and gallidermin to model membranes±lipid II in detail. Both peptides bind to DOPC/lipid II membranes with high affinity (K 0.30μM and 0.27μM). Gallidermin displayed also strong affinity to pure DOPC membranes (0.53μM) an effect that was supported by ITC measurements. A surface acoustic wave (SAW) sensor allowed measurements in the picomolar concentration range and revealed that gallidermin targets lipid II at an equimolar ratio and simultaneously inserts into the bilayer. These results indicate that gallidermin, in contrast to vancomycin, combines cell wall inhibiton and interference with the bacterial membrane integrity for potent antimicrobial activity

    Model membrane studies for characterization of different antibiotic activities of lipopeptides from Pseudomonas

    Get PDF
    AbstractLipopeptides (LPs) are a structurally diverse class of amphipathic natural products that were in the past mainly known for their surfactant properties. However, the recent discovery of their antimicrobial and cytotoxic bioactivities have fueled and renewed the interest in this compound class. Propelled by the antimicrobial potential of this compound class, in this study a range of six underinvestigated LPs from Pseudomonads were examined with respect to their antibiotic activities towards bacteria. The assays revealed that only the glycosylated lipodipeptide SB-253514, produced by Pseudomonas strain SH-C52, showed significant antibacterial activity. Since the bioactivity of LPs is commonly attributed to membrane interactions, we analyzed the molecular interactions between the LPs and bacteria-like lipid model membranes in more detail via complementary biophysical approaches. Application of the quartz crystal microbalance (QCM) showed that all LPs possess a high binding affinity towards the model membranes. Despite their similar membrane affinity, monolayer studies displayed different tendencies of LPs to incorporate into the membrane. The degree of membrane incorporation could be correlated with specific structural features of the investigated LPs, such as distance between the peptidic macrocycle and the fatty acid, but did not fully reflect their respective antibacterial activity. Cyclic voltammetry (CV) experiments further demonstrated that SB-253514 showed no membrane permeabilization effects at inhibitory concentrations. Collectively, these results suggests that the antibacterial activity of SB-253514 cannot be explained by an unspecific detergent-like mechanism generally proposed for amphiphilic molecules but instead appears to occur via a defined structural target

    A Dry Membrane Protection Technique to Allow Surface Acoustic Wave Biosensor Measurements of Biological Model Membrane Approaches

    Get PDF
    Model membrane approaches have attracted much attention in biomedical sciences to investigate and simulate biological processes. The application of model membrane systems for biosensor measurements is partly restricted by the fact that the integrity of membranes critically depends on the maintenance of an aqueous surrounding, while various biosensors require a preconditioning of dry sensors. This is for example true for the well-established surface acoustic wave (SAW) biosensor SAM®5 blue. Here, a simple drying procedure of sensor-supported model membranes is introduced using the protective disaccharide trehalose. Highly reproducible model membranes were prepared by the Langmuir-Blodgett technique, transferred to SAW sensors and supplemented with a trehalose solution. Membrane rehydration after dry incorporation into the SAW device becomes immediately evident by phase changes. Reconstituted model membranes maintain their full functionality, as indicated by biotin/avidin binding experiments. Atomic force microscopy confirmed the morphological invariability of dried and rehydrated membranes. Approximating to more physiological recognition phenomena, the site-directed immobilization of the integrin VLA-4 into the reconstituted model membrane and subsequent VCAM-1 ligand binding with nanomolar affinity were illustrated. This simple drying procedure is a novel way to combine the model membrane generation by Langmuir-Blodgett technique with SAW biosensor measurements, which extends the applicability of SAM®5 blue in biomedical sciences

    A Dry Membrane Protection Technique to Allow Surface Acoustic Wave Biosensor Measurements of Biological Model Membrane Approaches

    Get PDF
    Model membrane approaches have attracted much attention in biomedical sciences to investigate and simulate biological processes. The application of model membrane systems for biosensor measurements is partly restricted by the fact that the integrity of membranes critically depends on the maintenance of an aqueous surrounding, while various biosensors require a preconditioning of dry sensors. This is for example true for the well-established surface acoustic wave (SAW) biosensor SAM(®)5 blue. Here, a simple drying procedure of sensor-supported model membranes is introduced using the protective disaccharide trehalose. Highly reproducible model membranes were prepared by the Langmuir-Blodgett technique, transferred to SAW sensors and supplemented with a trehalose solution. Membrane rehydration after dry incorporation into the SAW device becomes immediately evident by phase changes. Reconstituted model membranes maintain their full functionality, as indicated by biotin/avidin binding experiments. Atomic force microscopy confirmed the morphological invariability of dried and rehydrated membranes. Approximating to more physiological recognition phenomena, the site-directed immobilization of the integrin VLA-4 into the reconstituted model membrane and subsequent VCAM-1 ligand binding with nanomolar affinity were illustrated. This simple drying procedure is a novel way to combine the model membrane generation by Langmuir-Blodgett technique with SAW biosensor measurements, which extends the applicability of SAM(®)5 blue in biomedical sciences
    corecore