1,735 research outputs found
TAX INCENTIVES: AN EFFECTIVE DEVELOPMENT STRATEGY FOR RURAL COMMUNITIES?
As national and local economies become more globalized, many rural areas are going to find it more difficult to compete for private capital investments. A traditional tool, modifications to tax policy, of state and local governments will not be as effective (for many communities it has never been effective) in the future. These communities will need to seek other avenues of growth. However, for many rural communities even alternative avenues will not lead to enhanced economic opportunity.agglomeration, rural development, tax policy, Community/Rural/Urban Development, R51, R58, O21, O23, R11, R38,
Recommended from our members
A submillimetre wavelength spectral line search of the Orion molecular cloud core
A submillimetre wavelength molecular line search of the Orion molecular cloud has been made covering a total of about 5 percent of the frequency range 342.8 - 358.6 GHz. This search, coupled with the authors' previous observations of submillimetre transitions in this cloud, has led to the detection of 22 transitions of 14 molecular species, of which 16 are reported here for the first time. No unidentified lines have been detected in the present search. Mapping observations have been obtained for several of the lines and, in the case of H2CO the authors have been able to compare the present data with that obtained from other telescopes, to estimate the density and abundance in the emitting region
MM and subMM molecular line observations of the southwest lobe of L1551: Evidence of a shell structure
Observations have been made of the southwest outflow lobe of L1551 in several millimeter and submillimeter molecular lines. Maps have been made in the J=3-2 and J=2-1 transitions of CO over areas of 7.5 by 2.5 arc minutes and 5 by 5 arc minutes respectively at UKIRT. More detailed maps have also been made in the J=2-1 CO transition over an area of about 6 by 3.5 arc minutes at the NRAO 12m telescope. Additional observations of the J=4-3 transitions of HCN, HCO(+) abd H(13)CO(+) were made at selected positions. The HC(+) J=4-3 transition was detected at several positions along the outflow axis and at the position of IRS 5. Similarly the HCN J=4-3 transition was detected at the position of IRS 5 and also at a position close to HH29. However, the J=4-3 transition of H(13)CO(+) was bit detected at the position of IRS 5 even through it was observed at the position close to HH29 with a peak corrected antenna temperature of 0.23K at a V(LSR) of 1 km s(-1). The detection of the J=4-3 transitions of both HCO(+) and H(13)CO(+) close to the position of HH29 suggest the presence of very dense gas in this region. LVG analysis of the various molecular lines observed give a kinetic temperature between 10 and 15K and a density from 10(5) to 10(6) cm(-3) at the position of IRS 5 at the ambient cloud velocity. At the position close to HH29 LVG analysis of the CO observations gives a density between 10(3) and 10(4) cm(-3) at a kinetic temperature of 25k for a V(LSR) of 0 km s(-1). To the southwest of HH29 there is a large decrease in both the linewidth and intensity of CO emission. This may be due to the interaction between the outflow and a dense clump of gas which gives rise to HH29. The maps of the CO J=3-2 and CO J=2-1 emission integrated in 3.25 km s intervals show the shell structure postulated by Snell and Schloerb (1985)
Arkansas Small-Grain Cultivar Performance tests 2008-2009
Small-grain cultivar performance tests are conducted each year in Arkansas by the Arkansas Agricultural Experiment Station, Department of Crop, Soil, and Environmental Sciences. The tests provide information to companies developing cultivars and/or marketing seed within the state and aid the Arkansas Cooperative Extension Service in formulating cultivar recommendations for smallgrain producers
TreeDomViewer: a tool for the visualization of phylogeny and protein domain structure
Phylogenetic analysis and examination of protein domains allow accurate genome annotation and are invaluable to study proteins and protein complex evolution. However, two sequences can be homologous without sharing statistically significant amino acid or nucleotide identity, presenting a challenging bioinformatics problem. We present TreeDomViewer, a visualization tool available as a web-based interface that combines phylogenetic tree description, multiple sequence alignment and InterProScan data of sequences and generates a phylogenetic tree projecting the corresponding protein domain information onto the multiple sequence alignment. Thereby it makes use of existing domain prediction tools such as InterProScan. TreeDomViewer adopts an evolutionary perspective on how domain structure of two or more sequences can be aligned and compared, to subsequently infer the function of an unknown homolog. This provides insight into the function assignment of, in terms of amino acid substitution, very divergent but yet closely related family members. Our tool produces an interactive scalar vector graphics image that provides orthological relationship and domain content of proteins of interest at one glance. In addition, PDF, JPEG or PNG formatted output is also provided. These features make TreeDomViewer a valuable addition to the annotation pipeline of unknown genes or gene products. TreeDomViewer is available at
War and dissociation : the case of futurist aesthetics
Thanks to their deliberate engagement in state propaganda Italian Futurists deserved a prominent spot in the history of military aesthetics in the 20th century. However, under what looked like an unequivocal expression of support for war, lied a deep philosophical disagreement concerning its existential and epistemological value. The bone of contention concerned the effects of warfare on perception and, consequently, the means of its depiction. The author analyses this intellectual disagreement within the group and focuses, in particular, on its philosophical implications
Using A "Sound Tube" To Measure Noise Of Structural Sources In High Background Noise Environments
LectureDescribed in this paper is a device referred to as a soundtube, which has been designed to accurately measure only the normal component of the surface velocity of a vibrating structural noise source. Both laboratory and field data are presented. Significant advantages of the sound tube over an accelerometer for surface velocity measurements are: l. Soundtube is not sensitive to high-level off-axis vibrations of the surface which do not contribute to sound radiation. 2. Since the soundtube is simply pressed against the surface, measurements can be made over surfaces which are lagged with insulation or are covered with ice. The most useful application of the sound tube has been to estimate noise radiation from various structural noise sources such as compressors and p1pmg in environments with high background noise levels. By assuming that the source has a radiation efficiency which is equal to or less than unity, an upper limit of the noise radiation from each source component can be accurately determined
A fully integrated microfluidic device for point of care monitoring of antithrombotics
© 2016 The Royal Society of Chemistry. The simplicity and efficiency of point of care diagnostics have revolutionised patient care. Current methods for measuring hypercoagulability often require trained technicians, large blood volumes, and result in long turnaround times. Standard testing for hypercoagulable disorders is performed in the central laboratory using automated coagulation analysers. However the trend is moving towards the development and implementation of point of care testing, as a result of the ever increasing number of patients on antithrombotic therapy. We present a novel microfluidic device and assay for monitoring the effect of two anticoagulants, unfractionated heparin (UFH) and low molecular weight heparin (LMWH). The assay is based on the anti-Xa assay principle but uses fluorescence detection. Our device is a disposable laminate microfluidic strip, fabricated from the cyclic polyolefin (COP), Zeonor®, which is extremely suitable for application to fluorescent device platforms. We present data on the execution of the anti-Xa assay in this microfluidic format, demonstrating that the assay can be used to measure both UFH and LMWH in human plasma samples from 0 to 1 U mL-1, with a rapid result obtained within 30-60 seconds
- …