45 research outputs found

    The Management of Patients with Cataracts and Medically Uncontrolled Glaucoma

    Get PDF
    Trabeculectomy surgery has been shown to lower intraocular pressure and is the most commonly performed glaucoma procedure worldwide. However, giving a patient a ‘bleb for life’ is not without consequences and the failure of trabeculectomy to control IOP in the long term is well documented. In some instances, such as in patients with exfoliative glaucoma or primary angle closure glaucoma, cataract surgery alone can often lower IOP to acceptable levels. Cataract surgery in these instances can sometimes be combined with procedures such as goniosynechialysis or endoscopic cyclophotocoagulation which may provide additional IOP lowering. Such surgery has the distinct advantage of avoiding conjunctival incisions, so that subsequent trabeculectomy, if required, is more likely to be successful. In any case, it is preferable to perform trabeculectomy in a pseudophakic eye for several reasons. If trabeculectomy is performed in a phakic eye, patients should be warned that subsequent cataract is likely and if cataract surgery is performed it is preferable to wait at least a year or more after the trabeculectomy to reduce the risk of bleb failure. Combined phacotrabeculectomy should be reserved for end-stage glaucoma in most cases, in order to reduce the risk of ‘wipe-out’

    The Management of Patients with Cataracts and Medically Uncontrolled Glaucoma

    Get PDF
    Trabeculectomy surgery has been shown to lower intraocular pressure and is the most commonly performed glaucoma procedure worldwide. However, giving a patient a ‘bleb for life’ is not without consequences and the failure of trabeculectomy to control IOP in the long term is well documented. In some instances, such as in patients with exfoliative glaucoma or primary angle closure glaucoma, cataract surgery alone can often lower IOP to acceptable levels. Cataract surgery in these instances can sometimes be combined with procedures such as goniosynechialysis or endoscopic cyclophotocoagulation which may provide additional IOP lowering. Such surgery has the distinct advantage of avoiding conjunctival incisions, so that subsequent trabeculectomy, if required, is more likely to be successful. In any case, it is preferable to perform trabeculectomy in a pseudophakic eye for several reasons. If trabeculectomy is performed in a phakic eye, patients should be warned that subsequent cataract is likely and if cataract surgery is performed it is preferable to wait at least a year or more after the trabeculectomy to reduce the risk of bleb failure. Combined phacotrabeculectomy should be reserved for end-stage glaucoma in most cases, in order to reduce the risk of ‘wipe-out’

    Evaluation of Choroidal Thickness, Intraocular Pressure, and Serum Osmolality After the Water Drinking Test in Eyes With Primary Angle Closure

    Get PDF
    PURPOSE. We evaluated changes in choroidal thickness (ChT), IOP, ocular biometry, and serum osmolality after the water drinking test (WDT) in subjects with previous acute primary angle closure (APAC) and primary angle closure glaucoma (PACG). METHODS. We evaluated 38 subjects, including 21 with APAC and 17 with PACG. Each subject underwent IOP measurement, A-scan biometry, spectral domain-optical coherence tomography (SDOCT), anterior segment-optical coherence tomography (ASOCT), and osmolality measurements at baseline, 30, and 60 minutes after consuming at least 10 mL/kg of water. The ChT at the macula was measured from SDOCT images using the 7-line scan protocol. The fellow-eyes of APAC (FE-APAC) were compared to eyes with PACG. RESULTS. The mean age 6 SD of the study subjects was 62.8 6 8.6 years and 21 (55.3%) were females. At baseline, serum osmolality was significantly lower (P < 0.001) in the FE-APAC group, whereas ChT was similar in both groups (P ¼ 0.56). At 30 minutes after WDT, both groups demonstrated a significant increase in IOP (FE-APAC, 3.0 [95% confidence interval {CI}, 1.52, 4.48] mm Hg; PACG, 5.06 [95% CI, 3.68, CONCLUSIONS. The increase in IOP after WDT was higher in PACG eyes compared to FE-APAC; however, the latter had lower serum osmolality at baseline. Change in mean ChT following WDT was associated with a lower baseline serum osmolality

    A common variant near TGFBR3 is associated with primary open angle glaucoma

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/ licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited.Primary open angle glaucoma (POAG), a major cause of blindness worldwide, is a complex disease with a significant genetic contribution.We performed Exome Array (Illumina) analysis on 3504 POAG cases and 9746 controls with replication of the most significant findings in 9173 POAG cases and 26 780 controls across 18 collections of Asian, African and European descent. Apart from confirming strong evidence of association at CDKN2B-AS1 (rs2157719 [G], odds ratio [OR] = 0.71, P = 2.81 × 10−33), we observed one SNP showing significant association to POAG (CDC7–TGFBR3 rs1192415, ORG-allele = 1.13, Pmeta = 1.60 × 10−8). This particular SNP has previously been shown to be strongly associated with optic disc area and vertical cup-to-disc ratio, which are regarded as glaucoma-related quantitative traits. Our study now extends this by directly implicating it in POAG disease pathogenesis

    A common variant near TGFBR3 is associated with primary open angle glaucoma

    Get PDF
    Primary open angle glaucoma (POAG), a major cause of blindness worldwide, is a complex disease with a significant genetic contribution. We performed Exome Array (Illumina) analysis on 3504 POAG cases and 9746 controls with replication of the most significant findings in 9173 POAG cases and 26 780 controls across 18 collections of Asian, African and European descent. Apart from confirming strong evidence of association at CDKN2B-AS1 (rs2157719 [G], odds ratio [OR] = 0.71, P = 2.81 × 10−33), we observed one SNP showing significant association to POAG (CDC7–TGFBR3 rs1192415, ORG-allele = 1.13, Pmeta = 1.60 × 10−8). This particular SNP has previously been shown to be strongly associated with optic disc area and vertical cup-to-disc ratio, which are regarded as glaucoma-related quantitative traits. Our study now extends this by directly implicating it in POAG disease pathogenesis

    Downloaded from

    Get PDF
    Abstract Primary open angle glaucoma (POAG), a major cause of blindness worldwide, is a complex disease with a significant genetic contribution. We performed Exome Array ), we observed one SNP showing significant association to POAG (CDC7-TGFBR3 rs1192415, OR G-allele = 1.13, P meta = 1.60 × 10 −8 ). This particular SNP has previously been shown to be strongly associated with optic disc area and vertical cup-to-disc ratio, which are regarded as glaucoma-related quantitative traits. Our study now extends this by directly implicating it in POAG disease pathogenesis

    Phase 3, Randomized, 20-Month Study of the Efficacy and Safety of Bimatoprost Implant in Patients with Open-Angle Glaucoma and Ocular Hypertension (ARTEMIS 2)

    Get PDF
    Objective- To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10 and 15 µg bimatoprost implant in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). Methods- This randomized, 20-month, multicenter, masked, parallel-group, phase 3 trial enrolled 528 patients with OAG or OHT and an open iridocorneal angle inferiorly in the study eye. Study eyes were administered 10 or 15 µg bimatoprost implant on day 1, week 16, and week 32, or twice-daily topical timolol maleate 0.5%. Primary endpoints were IOP and IOP change from baseline through week 12. Safety measures included treatment-emergent adverse events (TEAEs) and corneal endothelial cell density (CECD). Results- Both 10 and 15 µg bimatoprost implant met the primary endpoint of noninferiority to timolol in IOP lowering through 12 weeks. Mean IOP reductions from baseline ranged from 6.2–7.4, 6.5–7.8, and 6.1–6.7 mmHg through week 12 in the 10 µg implant, 15 µg implant, and timolol groups, respectively. IOP lowering was similar after the second and third implant administrations. Probabilities of requiring no IOP-lowering treatment for 1 year after the third administration were 77.5% (10 µg implant) and 79.0% (15 µg implant). The most common TEAE was conjunctival hyperemia, typically temporally associated with the administration procedure. Corneal TEAEs of interest (primarily corneal endothelial cell loss, corneal edema, and corneal touch) were more frequent with the 15 than the 10 µg implant and generally were reported after repeated administrations. Loss in mean CECD from baseline to month 20 was ~ 5% in 10 µg implant-treated eyes and ~ 1% in topical timolol-treated eyes. Visual field progression (change in the mean deviation from baseline) was reduced in the 10 µg implant group compared with the timolol group. Conclusions- The results corroborated the previous phase 3 study of the bimatoprost implant. The bimatoprost implant met the primary endpoint and effectively lowered IOP. The majority of patients required no additional treatment for 12 months after the third administration. The benefit-risk assessment favored the 10 over the 15 µg implant. Studies evaluating other administration regimens with reduced risk of corneal events are ongoing. The bimatoprost implant has the potential to improve adherence and reduce treatment burden in glaucoma

    Surveillance and calibration of standard resistors at a Metrological laboratory

    No full text
    286-290<span style="font-size:11.0pt;line-height:115%; font-family:" calibri","sans-serif";mso-ascii-theme-font:minor-latin;mso-fareast-font-family:="" "times="" new="" roman";mso-fareast-theme-font:minor-fareast;mso-hansi-theme-font:="" minor-latin;mso-bidi-font-family:arial;mso-ansi-language:en-us;mso-fareast-language:="" en-us;mso-bidi-language:ar-sa"="">The paper presents a metrological technique for surveillance and calibration of similar standard resistors taken in group, at laboratories ranked next to the national level laboratories, based on calculation of eigen values and eigen vector of the measurement data matrix. The technique employs the various cross-products of measurement ratio data and provides a new mean of group calibration.</span

    Reliabilities of metrological precision calibration networks of standards

    No full text
    173-180<span style="font-size:14.0pt;mso-bidi-font-size:9.0pt; line-height:115%;font-family:" times="" new="" roman","serif";mso-fareast-font-family:="" "times="" roman";mso-fareast-theme-font:minor-fareast;mso-ansi-language:en-us;="" mso-fareast-language:en-us;mso-bidi-language:ar-sa"="">Metrological precision measurement techniques such as substitution, transposition and least squares with fault coverage are modeled for determining the performance in terms of reliability measures. Markov models are obtained <span style="font-size: 12.5pt;mso-bidi-font-size:7.5pt;line-height:115%;font-family:" times="" new="" roman","serif";="" mso-fareast-font-family:"times="" roman";mso-fareast-theme-font:minor-fareast;="" mso-ansi-language:en-us;mso-fareast-language:en-us;mso-bidi-language:ar-sa"="">to <span style="font-size:14.0pt;mso-bidi-font-size:9.0pt;line-height:115%;font-family: " times="" new="" roman","serif";mso-fareast-font-family:"times="" roman";mso-fareast-theme-font:="" minor-fareast;mso-ansi-language:en-us;mso-fareast-language:en-us;mso-bidi-language:="" ar-sa"="">examine the fault tolerant operation of the methods using multichannel network representation.</span
    corecore