25 research outputs found

    Functional treatment versus plaster for simple elbow dislocations (FuncSiE): a randomized trial

    Get PDF
    Background. Elbow dislocations can be classified as simple or complex. Simple dislocations are characterized by the absence of fractures, while complex dislocations are associated with fractures. After reduction of a simple dislocation, treatment options include immobilization in a static plaster for different periods of time or so-called functional treatment. Functional treatment is characterized by early active motion within the limits of pain with or without the use of a sling or hinged brace. Theoretically, functional treatment should prevent stiffness without introducing increased joint instability. The primary aim of this randomized controlled trial is to compare early functional treatment versus plaster immobilization following simple dislocations of the elbow. Methods/Design. The design of the study will be a multicenter randomized controlled trial of 100 patients who have sustained a simple elbow dislocation. After reduction of the dislocation, patients are randomized between a pressure bandage for 5-7 days and early functional treatment or a plaster in 90 degrees flexion, neutral position for pro-supination for a period of three weeks. In the functional group, treatment is started with early active motion within the limits of pain. Function, pain, and radiographic recovery will be evaluated at regular intervals over the subsequent 12 months. The primary outcome measure is the Quick Disabilities of the Arm, Shoulder, and Hand score. The secondary outcome measures are the Mayo Elbow Performance Index, Oxford elbow score, pain level at both sides, range of motion of the elbow joint at both sides, rate of secondary interventions and complication rates in both groups (secondary dislocation, instability, relaxation), health-related quality of life (Short-Form 36 and EuroQol-5D), radiographic appearance of the elbow joint (degenerative changes and heterotopic ossifications), costs, and cost-effectiveness. Discussion. The successful completion of this trial will provide evidence on the effectiveness of a functional treatment for the management of simple elbow dislocations. Trial Registration. The trial is registered at the Netherlands Trial Register (NTR2025)

    Effektivität und Nutzungsmerkmale eines Lehrfilms im Kursus der Zahnersatzkunde I

    No full text

    Stretching of viscoelastic drops in steady sliding

    No full text
    The sliding of non-Newtonian drops down planar surfaces results in a complex, entangled balance between interfacial forces and non-linear viscous dissipation, which has been scarcely inspected. In particular, a detailed understanding of the role played by the polymer flexibility and the resulting elasticity of the polymer solution is still lacking. To this aim, we have considered polyacrylamide (PAA) solutions of different molecular weights, suspended either in water or in glycerol/water mixtures. In contrast to drops of stiff polymers, drops of flexible polymers exhibit a remarkable elongation in steady sliding. This difference is most likely attributed to variation of viscous bending as a consequence of variation of shear thinning. Moreover, an “optimal elasticity” of the polymer seems to be required for this drop elongation to be visible. We have complemented experimental results with numerical simulations of a viscoelastic FENE-P drop. This has been a decisive step to unraveling how a change of the elastic parameters (e.g. polymer relaxation time, maximum extensibility) affects the dimensionless sliding velocity

    Engineering of the LukS-PV and LukF-PV subunits of Staphylococcus aureus Panton-Valentine leukocidin for Diagnostic and Therapeutic Applications

    Get PDF
    Abstract Background: Staphylococcus aureus produces several toxins, including Panton-Valentine leukocidin (PVL). The involvement of PVL in primary skin infections, necrotizing pneumonia, musculoskeletal disorders, brain abscess, and other diseases, some of which are life-threatening, has been reported. Following expert opinion, we aimed to provide the tools for establishment of sequence-based diagnostics and therapeutics for those conditions. We engineered the synergistic S and F (LukS-PV and LukF-PV respectively) pro-toxin subunits from Staphylococcus aureus USA400 into separate expression E. coli BL21(DE3)-pLysS hosts. Results: Following Nickel affinity chromatography (NAC), the F subunit came out without bands of impurity. The S sub-unit did not come off very pure after NAC thus necessitating further purification by size exclusion and ion-exchange chromatography. The purification plots showed that the BioLogic-LP and AKTA systems are reliable for following the progress of the chromatographic purification in real-time. Computer predicted Mw for the 6His-LukF-PV and 6His-LukS-PV were 35645.41 Da and 33530.04 Da respectively, while the mass spectrometry results were 35643.57 Da and 33528.34 Da respectively. Conclusion: The BioLogic-LP and AKTA systems are commendable for reliability and user-friendliness. As a recent work elsewhere also reported that a second round of chromatography was necessary to purify the S subunit after the first attempt, we speculate that the S subunit might contain yet unidentified motif(s) requiring further treatment. The purified S and F sub-units of PVL were supplied to the Nottingham Cancer Immunotherapy group who used them to establish sequence-based monoclonal antibodies for diagnostic and therapeutic uses targeting PVL
    corecore