1,477 research outputs found

    Domain and Geometry Agnostic CNNs for Left Atrium Segmentation in 3D Ultrasound

    Full text link
    Segmentation of the left atrium and deriving its size can help to predict and detect various cardiovascular conditions. Automation of this process in 3D Ultrasound image data is desirable, since manual delineations are time-consuming, challenging and observer-dependent. Convolutional neural networks have made improvements in computer vision and in medical image analysis. They have successfully been applied to segmentation tasks and were extended to work on volumetric data. In this paper we introduce a combined deep-learning based approach on volumetric segmentation in Ultrasound acquisitions with incorporation of prior knowledge about left atrial shape and imaging device. The results show, that including a shape prior helps the domain adaptation and the accuracy of segmentation is further increased with adversarial learning

    Zootherapeutics utilized by residents of the community Poço Dantas, Crato-CE, Brazil

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Animals have been used as a source of medicine in Brazil since ancient times, and have played a significant role in healing practices. Specifically in Northeast Brazil, zootherapy is a very common practice, and together with medicinal plants, it plays an important role as a therapeutic alternative. In the state of Ceara, no works have been carried out on rural communities with regard to use of zootherapeutics, even though the practice of zootherapy is common in this region. Therefore, the aim of this study was to analyze the use of medicinal animals in a rural community (Poco Dantas) in the municipality of Crato, Ceara, Brazil.</p> <p>Methods</p> <p>The field survey was carried out from October 2008 to January 2009 by conducting interviews using structured questionnaires with 72 people (33 men and 39 women), who provided information on animal species used as remedies, body parts used to prepare the remedies, and ailments for which the remedies were prescribed. We calculated the informant consensus factor (ICF) to determine the consensus over which species are effective for particular ailments, as well as the species use value (UV) to determine the extent of utilization of each species.</p> <p>Results</p> <p>A total of 29 species, distributed in 17 families were categorized as having some medicinal property. The taxa most represented were: mammals (9), insects (7), reptiles and birds (4). <it>Progne chalybea</it>, a species not previously recorded as being of medicinal use, was cited in the present work, where it is utilized in the treatment of alcoholism. The animals are used in the treatment of 34 diseases or symptoms, where sore throat, inflammations and cough are the ailments with the greatest number of citations.</p> <p>Conclusion</p> <p>The data show that zootherapy represents an important therapeutic alternative for the inhabitants of the community. New studies on medicinal fauna should be conducted with the aim of determining the exploitation level of the species utilized, promoting sustainable development of medicinal species that are eventually threatened, and preserving and disseminating the knowledge developed by traditional individuals of the community.</p

    Dentoalveolar comparative study between removable and fixed cribs, associated to chincup, in anterior open bite treatment

    Get PDF
    OBJECTIVE: The aim of this prospective study was to compare the dentoalveolar effects produced by two types of palatal crib, removable (Rpc+C) and fixed (Fpc+C), combined with chincup in growing patients with anterior open bite. MATERIAL AND METHODS: Each group comprised 30 patients, in the mixed dentition phase, with similar cephalometric characteristics and skeletal ages. Group 1 (Rpc+C) presented initial mean age of 8.3 years and mean anterior open bite of 4.0 mm. Group 2 (Fpc+C) presented initial mean age of 8.54 years and mean anterior open bite of 4.3 mm. The evaluation period comprised 12 months between initial (T1) and second lateral radiograph (T2). The T2-T1 changes were compared cephalometrically in the 2 groups using the non-paired t-test. RESULTS: Vertical changes in the posterior dentoalveolar region were similar between the groups (about 1 mm) and no significant differences were found in molar mesialization. The Fpc+C group had in average 1.6 mm more improvement of the overbite as a result of greater maxillary incisor extrusion (1.3 mm). Patients in this group also presented less lingual tipping of maxillary incisors and more mandibular incisors uprighting. CONCLUSIONS: The Fpc+C combination was more efficient in the correction of the negative overbite mainly due to greater extrusion of the maxillary incisors. However, the Rpc+C appliance promoted better upper and lower incisor inclination, resulting in a more adequate overjet

    LOCALIZAÇÃO RADIOGRÁFICA PELO MÉTODO DE CLARK: PRINCÍPIOS E INDICAÇÕES

    Get PDF
    A  determinação  do  posicionamento  de  dentes  retidos  e impactados,  corpos  estranhos,  e  condutos  radiculares  são  de  grande importância  para  o  planejamento  de  tratamento  cirúrgicos  e  endodônticos  em odontologia.  As  radiografias  convencionais  são  exames  de  baixo  custo associadas à baixas doses de radiação, valendo ressaltar que são exames de fácil  execução  no  próprio  consultório  odontológico.  No  entanto,  estes  exames apresentam  como  limitação  a  produção  de  imagens  bidimensionais,  apenas com  representação  da  largura  e  altura  das  estruturas.  Existem  modificações desses  exames  que  representam  uma  maneira  de  diminuir  essas desvantagens

    A numerical study of fractional relaxation–oscillation equations involving ψ-Caputo fractional derivative

    Get PDF
    We provide a numerical method to solve a certain class of fractional differential equations involving ψ -Caputo fractional derivative. The considered class includes as particular case fractional relaxation–oscillation equations. Our approach is based on operational matrix of fractional integration of a new type of orthogonal polynomials. More precisely, we introduce ψ -shifted Legendre polynomial basis, and we derive an explicit formula for the ψ -fractional integral of ψ -shifted Legendre polynomials. Next, via an orthogonal projection on this polynomial basis, the problem is reduced to an algebraic equation that can be easily solved. The convergence of the method is justified rigorously and confirmed by some numerical experiments.publishe

    Study of scattered radiation during fluoroscopy in hip surgery

    Get PDF
    Objetivo: Medir a intensidade da dose de radiação espalhada em diferentes posições simulando uma intervenção cirúrgica no quadril. Materiais e Métodos: Simulou-se uma intervenção cirúrgica no quadril com apoio da fluoroscopia para estudar a distribuição da radiação espalhada no bloco operatório. Para simular o paciente foi utilizado um simulador antropomórfico de corpo inteiro e para medir a radiação utilizou-se um detector específico para medir raios X. Realizaram-se incidências com um equipamento de raios X tipo arco em C móvel, em modo de escopia contínua, com a ampola a 0° (configuração 1) e a 90° (configuração 2). Os parâmetros operacionais utilizados (voltagem, corrente, tempo de exposição) foram determinados por meio de um estudo estatístico resultante da observação de cirurgias ortopédicas de quadril. Resultados: Em todas as medições observaram-se exposições mais elevadas na configuração 2. Nas medições em função da altura, observaram-se os valores máximos da taxa de dose de 1,167 (± 0,023) µSv/s e 2,278 (± 0,023) µSv/s nas configurações 1 e 2, respectivamente, correspondendo à altura do tórax dos profissionais. No estudo em torno do paciente os valores máximos registraramse na posição ocupada pelo médico cirurgião. Conclusão: Concluiu-se que a exposição à radiação dos profissionais é baixa, podendo ainda ser reduzida mediante o uso de equipamentos de proteção individualObjective: To measure the scattered radiation dose at different positions simulating hip surgery. Materials and Methods: We simulated fluoroscopy-assisted hip surgery in order to study the distribution of scattered radiation in the operating room. To simulate the patient, we used a anthropomorphic whole-body phantom, and we used an X-ray-specific detector to quantify the radiation. Radiographs were obtained with a mobile C-arm X-ray system in continuous scan mode, with the tube at 0° (configuration 1) or 90° (configuration 2). The operating parameters employed (voltage, current, and exposure time) were determined by a statistical analysis based on the observation of orthopedic surgical procedures involving the hip. Results: For all measurements, higher exposures were observed in configuration 2. In the measurements obtained as a function of height, the maximum dose rates observed were 1.167 (± 0.023) µSv/s and 2.278 (± 0.023) µSv/s in configurations 1 and 2, respectively, corresponding to the chest level of health care professionals within the operating room. Proximal to the patient, the maximum values were recorded in the position occupied by the surgeon. Conclusion: We can conclude that, in the scenario under study, health care professionals workers are exposed to low levels of radiation, and that those levels can be reduced through the use of personal protective equipmen
    corecore