1,352 research outputs found

    Cassini detection of Enceladus' cold water-group plume ionosphere

    Get PDF
    This study reports direct detection by the Cassini plasma spectrometer of freshly-produced water-group ions (O+, OH+, H2O+, H3O+) and heavier water dimer ions (HxO(2))(+) very close to Enceladus where the plasma begins to emerge from the plume. The data were obtained during two close ( 52 and 25 km) flybys of Enceladus in 2008 and are similar to ion data in cometary comas. The ions are observed in detectors looking in the Cassini ram direction exhibiting energies consistent with the Cassini speed, indicative of a nearly stagnant plasma flow in the plume. North of Enceladus the plasma slowing commences about 4 to 6 Enceladus radii away, while south of Enceladus signatures of the plasma interaction with the plume are detected 22 Enceladus radii away. Citation: Tokar, R. L., R. E. Johnson, M. F. Thomsen, R. J. Wilson, D. T. Young, F. J. Crary, A. J. Coates, G. H. Jones, and C. S. Paty ( 2009), Cassini detection of Enceladus' cold water-group plume ionosphere, Geophys. Res. Lett., 36, L13203, doi:10.1029/2009GL038923

    Initial fixation placement in face images is driven by top-down guidance

    Get PDF
    The eyes are often inspected first and for longer period during face exploration. To examine whether this saliency of the eye region at the early stage of face inspection is attributed to its local structure properties or to the knowledge of its essence in facial communication, in this study we investigated the pattern of eye movements produced by rhesus monkeys (Macaca mulatta) as they free viewed images of monkey faces. Eye positions were recorded accurately using implanted eye coils, while images of original faces, faces with scrambled eyes, and scrambled faces except for the eyes were presented on a computer screen. The eye region in the scrambled faces attracted the same proportion of viewing time and fixations as it did in the original faces, even the scrambled eyes attracted substantial proportion of viewing time and fixations. Furthermore, the monkeys often made the first saccade towards to the location of the eyes regardless of image content. Our results suggest that the initial fixation placement in faces is driven predominantly by ‘top-down’ or internal factors, such as the prior knowledge of the location of “eyes” within the context of a face

    Trends in cow numbers and culling rate in the Irish cattle population, 2003 to 2006

    Get PDF
    Cows are the main economic production units of Ireland's cattle industry. Therefore, demographic information, including overall numbers and survival rates, are relevant to the Irish agricultural industry. However, few data are available on the demographics of cows within a national population, either in Ireland or elsewhere, despite the recent development of comprehensive national cattle databases in many EU Member States. This study has sought: to determine the rate of cow culling from the national herd; to determine the rate of culling by type (dairy, beef), age, method of exit, date of exit and interval between last calving and exit; to calculate the national cow on-farm mortality rate; and to compare the Irish rates with published data from other countries. This work was conducted using data recorded in the national Cattle Movement Monitoring System (CMMS). Culling refers to the exit of cows from the national herd, as a result of death but regardless of reason, and cow-culling rate was calculated as the number of cow exits (as defined above) each year divided by the number of calf births in the same year. Culling rate was determined by type (dairy or beef), date of birth, method of exit (slaughter or on-farm death), month of exit and interval between last calving and exit. The average cow-culling rate during 2003 to 2006 was 19.6% (21.3% for dairy, 18% for beef). While comparisons must be treated with caution, it concluded that the overall rates of culling in Ireland fell within published internationally accepted norms. The on-farm mortality rate of 3.2-4.1% was similar to that reported in comparable studies

    Coronary artery bypass grafting and sensorineural hearing loss, a cohort study

    Get PDF
    BACKGROUND: Sudden sensorineural hearing loss is routinely encountered by the otologist. The etiology is varied and often identifiable. One of the relatively less frequent causes is surgery. Apart from being an established entity with otological surgeries, sensorineural hearing loss has also been known to occur after non-otological procedures under general anesthesia. Commonest amongst these procedures is cardiopulmonary bypass, an association that has long been recognized. However, despite the proposition of diverse hypotheses in the past, the pathophysiology remains unclear. METHODS: The study is a prospective matched cohort study that will be carried out in Aga Khan University Hospital, Karachi, Pakistan. Participants among exposed would include all those patients who would be undergoing coronary artery bypass surgery in the hospital who fall under the criteria for inclusion. Unexposed group would comprise of patients undergoing a non-bypass procedure of similar duration under the same type of anesthesia who meet the selection criteria. Both these groups will undergo audiometric testing at our hospital on three different occasions during the course of this study. Initially before the procedure to test the baseline hearing capacity; then one week after the procedure to assess any changes in hearing ability following the surgery; and finally a third audiogram at six weeks follow-up to assess further changes in any hearing deficits noted during the second phase of testing. Certain variables including the subjects' demographics and those concerning the procedure itself will be noted and used later for risk factors analysis. A detailed past medical and surgical history will also be obtained. Data analysis would include calculation of relative risk and significance of the results, by running the chi-square test. Other statistical tests like Fisher exact test may then be employed to facilitate data interpretation. Continuous scale may then be employed and multivariate linear regression used. DISCUSSION: This study is planned to obtain a better understanding of the correlation between sudden sensorineural hearing loss and cardiopulmonary bypass. Being the first major cohort trial in this line of investigation, the project is designed to identify the existence of any significant relationship between cardiopulmonary bypass and sensorineural hearing deficit

    Distances from Surface Brightness Fluctuations

    Get PDF
    The practice of measuring galaxy distances from their spatial fluctuations in surface brightness is now a decade old. While several past articles have included some review material, this is the first intended as a comprehensive review of the surface brightness fluctuation (SBF) method. The method is conceptually quite simple, the basic idea being that nearby (but unresolved) star clusters and galaxies appear "bumpy", while more distant ones appear smooth. This is quantified via a measurement of the amplitude of the Poisson fluctuations in the number of unresolved stars encompassed by a CCD pixel (usually in an image of an elliptical galaxy). Here, we describe the technical details and difficulties involved in making SBF measurements, discuss theoretical and empirical calibrations of the method, and review the numerous applications of the method from the ground and space, in the optical and near-infrared. We include discussions of stellar population effects and the "universality" of the SBF standard candle. A final section considers the future of the method.Comment: Invited review article to appear in: `Post-Hipparcos Cosmic Candles', A. Heck & F. Caputo (Eds), Kluwer Academic Publ., Dordrecht, in press. 22 pages, including 3 postscript figures; uses Kluwer's crckapb.sty LaTex macro file, enclose

    High resolution 3D imaging of living cells with sub-optical wavelength phonons

    Get PDF
    Label-free imaging of living cells below the optical diffraction limit poses great challenges for optical microscopy. Biologically relevant structural information remains below the Rayleigh limit and beyond the reach of conventional microscopes. Super-resolution techniques are typically based on the nonlinear and stochastic response of fluorescent labels which can be toxic and interfere with cell function. In this paper we present, for the first time, imaging of live cells using sub-optical wavelength phonons. The axial imaging resolution of our system is determined by the acoustic wavelength (λa = λprobe/2n) and not on the NA of the optics allowing sub-optical wavelength acoustic sectioning of samples using the time of flight. The transverse resolution is currently limited to the optical spot size. The contrast mechanism is significantly determined by the mechanical properties of the cells and requires no additional contrast agent, stain or label to image the cell structure. The ability to breach the optical diffraction limit to image living cells acoustically promises to bring a new suite of imaging technologies to bear in answering exigent questions in cell biology and biomedicine

    Haemoglobin mass and running time trial performance after recombinant human erythropoietin administration in trained men

    Get PDF
    <p>Recombinant human erythropoietin (rHuEpo) increases haemoglobin mass (Hbmass) and maximal oxygen uptake (v˙ O2 max).</p> <p>Purpose: This study defined the time course of changes in Hbmass, v˙ O2 max as well as running time trial performance following 4 weeks of rHuEpo administration to determine whether the laboratory observations would translate into actual improvements in running performance in the field.</p> <p>Methods: 19 trained men received rHuEpo injections of 50 IUNkg21 body mass every two days for 4 weeks. Hbmass was determined weekly using the optimized carbon monoxide rebreathing method until 4 weeks after administration. v˙ O2 max and 3,000 m time trial performance were measured pre, post administration and at the end of the study.</p> <p>Results: Relative to baseline, running performance significantly improved by ,6% after administration (10:3061:07 min:sec vs. 11:0861:15 min:sec, p,0.001) and remained significantly enhanced by ,3% 4 weeks after administration (10:4661:13 min:sec, p,0.001), while v˙ O2 max was also significantly increased post administration (60.765.8 mLNmin21Nkg21 vs. 56.066.2 mLNmin21Nkg21, p,0.001) and remained significantly increased 4 weeks after rHuEpo (58.065.6 mLNmin21Nkg21, p = 0.021). Hbmass was significantly increased at the end of administration compared to baseline (15.261.5 gNkg21 vs. 12.761.2 gNkg21, p,0.001). The rate of decrease in Hbmass toward baseline values post rHuEpo was similar to that of the increase during administration (20.53 gNkg21Nwk21, 95% confidence interval (CI) (20.68, 20.38) vs. 0.54 gNkg21Nwk21, CI (0.46, 0.63)) but Hbmass was still significantly elevated 4 weeks after administration compared to baseline (13.761.1 gNkg21, p<0.001).</p> <p>Conclusion: Running performance was improved following 4 weeks of rHuEpo and remained elevated 4 weeks after administration compared to baseline. These field performance effects coincided with rHuEpo-induced elevated v˙ O2 max and Hbmass.</p&gt
    corecore