194 research outputs found

    Failure modes in high strength and stiffness to weight scaffolds produced by Selective Laser Melting

    Get PDF
    The production of porous scaffold structures using additive manufacturing is becoming widespread, however a detailed understanding of the scaffold failure mechanisms is lacking. In this research, Selective Laser Melting (SLM) is used to produce Ti–6Al–4V scaffold structures consisting of a regular array of unit cells previously designed using topology optimisation. Interrupted compression testing and subsequent X-Ray Micro Tomography (XMT) characterisation is used to study the deformation and failure of the scaffolds for a range of solid fractions. Further, the XMT data of the unloaded scaffolds is used to generate meshes for finite element analysis which allowed direct comparison of desired and as built behaviour. Likely failure sites predicted from the finite element analysis compare favourably with the experimentally observed ones. Failure is initiated in areas that exhibit the greatest tensile stress, while the onset of the commonly observed layered failure occurs afterwards. The XMT of the unloaded scaffolds also highlights the inaccuracies in the SLM build process, which contributes to stress concentrations in the horizontal arms within the scaffolds. The results indicate that although the strength of the topology optimised structures is very high, further refinement in both the unit cell design and build quality would further increase the strength

    Effect of the GaAsP shell on optical properties of self-catalyzed GaAs nanowires grown on silicon

    Get PDF
    We realize growth of self-catalyzed core-shell GaAs/GaAsP nanowires (NWs) on Si substrates using molecular-beam epitaxy. Transmission electron microscopy (TEM) of single GaAs/GaAsP NWs confirms their high crystal quality and shows domination of the zinc-blende phase. This is further confirmed in optics of single NWs, studied using cw and time-resolved photoluminescence (PL). A detailed comparison with uncapped GaAs NWs emphasizes the effect of the GaAsP capping in suppressing the non-radiative surface states: significant PL enhancement in the core-shell structures exceeding 2000 times at 10K is observed; in uncapped NWs PL is quenched at 60K whereas single core-shell GaAs/GaAsP NWs exhibit bright emission even at room temperature. From analysis of the PL temperature dependence in both types of NW we are able to determine the main carrier escape mechanisms leading to the PL quench

    Elevated Peripheral Neutrophils and Matrix Metalloproteinase 9 as Biomarkers of Functional Outcome Following Subarachnoid Hemorrhage

    Get PDF
    There is growing evidence supporting the role of inflammation in early brain injury and cerebral vasospasm following subarachnoid hemorrhage (SAH). Matrix metalloproteinases (MMPs) are released by inflammatory cells and can mediate early brain injury via disruption of the extracellular matrix and mediate vasospasm by cleaving endothelin-1 into vasoactive fragments. We hypothesize that inflammation marked by neutrophil elevation and MMP-9 release in human SAH is associated with vasospasm and with poor clinical outcome. We enrolled consecutive SAH subjects (N = 55), banked serial blood and cerebrospinal fluid (CSF) samples, and evaluated their 3-month modified Rankin scores (mRS). Vasospasm was defined as >50% vessel caliber reduction on angiography 6–8 days post-SAH. A poor outcome was defined as mRS > 2. We compared blood leukocyte and neutrophil counts during post-SAH days 0–14 with respect to vasospasm and 3-month outcome. In a subset of SAH subjects (N = 35), we compared blood and CSF MMP-9 by enzyme-linked immunosorbent assay (ELISA) on post-SAH days 0–1, 2–3, 4–5, 6–8, and 10–14 with respect to vasospasm and to 3-month outcome. Persistent elevation of blood leukocyte (p = 0.0003) and neutrophil (p = 0.0002) counts during post-SAH days 0–14 are independently associated with vasospasm after adjustment for major confounders. In the same time period, blood neutrophil count (post-SAH days 2–3, p = 0.018), blood MMP-9 (post-SAH days 4–5, p = 0.045), and CSF MMP-9 (post-SAH days 2–3, p = 0.05) are associated with poor 3-month SAH clinical outcome. Neutrophil count correlates with blood MMP-9 (post-SAH days 6–8, R = 0.39; p = 0.055; post-SAH days 10–14, R = 0.79; p < 0.0001), and blood MMP-9 correlates with CSF MMP-9 (post-SAH days 4–5, R = 0.72; p = 0.0002). Elevation of CSF MMP-9 during post-SAH days 0–14 is associated with poor 3-month outcome (p = 0.0078). Neither CSF nor blood MMP-9 correlates with vasospasm. Early rise in blood neutrophil count and blood and CSF MMP-9 are associated with poor 3-month SAH clinical outcome. In blood, neutrophil count correlates with MMP-9 levels, suggesting that neutrophils may be an important source of blood MMP-9 early in SAH. Similarly, CSF and blood MMP-9 correlate positively early in the course of SAH, suggesting that blood may be an important source of CSF MMP-9. Blood and CSF MMP-9 are associated with clinical outcome but not with vasospasm, suggesting that MMP-9 may mediate brain injury independent of vasospasm in SAH. Future in vitro studies are needed to investigate the role of MMP-9 in SAH-related brain injury. Larger clinical studies are needed to validate blood and CSF MMP-9 as potential biomarkers for SAH outcome

    Phase 1 dose-finding and pharmacokinetic study of eribulin-liposomal formulation in patients with solid tumours

    Get PDF
    Background: This phase 1 study examined the safety, tolerability, pharmacokinetics and preliminary efficacy of eribulin-liposomal formulation (eribulin-LF) in patients with advanced solid tumours. Methods:\ud Eligible patients with ECOG PS 0–1 were treated with eribulin-LF either on day 1 every 21 days (Schedule 1), or on days 1 and 15 every 28 days (Schedule 2). Doses ranged from 1.0 to 3.5 mg/m2, with dose escalation in a 3 + 3 design. The dose-expansion phase evaluated eribulin-LF in select tumour types. Primary objectives: maximum tolerated dose (MTD) and the recommended dose/schedule of eribulin-LF. Results: Totally, 58 patients were enroled (median age = 62 years). The MTD was 1.4 mg/m2 (Schedule 1) or 1.5 mg/m2 (Schedule 2), the latter dose selected for the dose-expansion phase. Dose-limiting toxicity (DLTs) in Schedule 1: hypophosphatemia and increased transaminase levels. DLTs in Schedule 2: stomatitis, increased alanine aminotransferase, neutropenia and febrile neutropenia. The pharmacokinetic profile of eribulin-LF showed a similar half-life to that of eribulin (~30 h), but with a 5-fold greater maximum serum concentration and a 40-fold greater area-under-the-curve. Eribulin-LF demonstrated clinical activity with approximately 10% of patients in both schedules achieving partial responses. Conclusions: Eribulin-LF was well tolerated with a favourable pharmacokinetic profile. Preliminary evidence of clinical activity in solid tumours was observed

    Modelling of Short-Term Interactions Between Concrete Support and the Excavated Damage Zone Around Galleries Drilled in Callovo–Oxfordian Claystone

    Get PDF
    peer reviewedProduction of energy from nuclear power plants generates high-level radioactive nuclear waste, harmful during dozens of thousand years. Deep geological disposal of nuclear waste represents the most reliable solutions for its safe isolation. Confinement of radioactive wastes relies on the multi-barrier concept in which isolation is provided by a series of engineered (canister, backfill) and natural (host rock) barriers. Few underground research laboratories have been built all over the world to test and validate storage solutions. The underground drilling process of disposal drifts may generate cracks, fractures/strain localisation in shear bands within the rock surrounding the gallery especially in argillaceous rocks. These degradations affect the hydro-mechanical properties of the material, such as permeability, e.g. creating a preferential flow path for radionuclide migration. Hydraulic conductivity increase within this zone must remain limited to preserve the natural barrier. In addition galleries are currently reinforced by different types of concrete supports such as shotcrete and/or prefab elements. Their purpose is twofold: avoiding partial collapse of the tunnel during drilling operations and limiting convergence of the surrounding rock. Properties of both concrete and rock mass are time dependent, due to shotcrete hydration and hydromechanical couplings within the host rock. By the use of a hydro-mechanical coupled Finite Element Code with a Second Gradient regularization, this paper aims at investigating and predicting support and rock interactions (convergence, stress field). The effect of shotcrete hydration evolution, spraying time and use of compressible wedges is studied in order to determine their relative influence

    Adjunctive rifampicin for Staphylococcus aureus bacteraemia (ARREST): a multicentre, randomised, double-blind, placebo-controlled trial.

    Get PDF
    BACKGROUND: Staphylococcus aureus bacteraemia is a common cause of severe community-acquired and hospital-acquired infection worldwide. We tested the hypothesis that adjunctive rifampicin would reduce bacteriologically confirmed treatment failure or disease recurrence, or death, by enhancing early S aureus killing, sterilising infected foci and blood faster, and reducing risks of dissemination and metastatic infection. METHODS: In this multicentre, randomised, double-blind, placebo-controlled trial, adults (≥18 years) with S aureus bacteraemia who had received ≤96 h of active antibiotic therapy were recruited from 29 UK hospitals. Patients were randomly assigned (1:1) via a computer-generated sequential randomisation list to receive 2 weeks of adjunctive rifampicin (600 mg or 900 mg per day according to weight, oral or intravenous) versus identical placebo, together with standard antibiotic therapy. Randomisation was stratified by centre. Patients, investigators, and those caring for the patients were masked to group allocation. The primary outcome was time to bacteriologically confirmed treatment failure or disease recurrence, or death (all-cause), from randomisation to 12 weeks, adjudicated by an independent review committee masked to the treatment. Analysis was intention to treat. This trial was registered, number ISRCTN37666216, and is closed to new participants. FINDINGS: Between Dec 10, 2012, and Oct 25, 2016, 758 eligible participants were randomly assigned: 370 to rifampicin and 388 to placebo. 485 (64%) participants had community-acquired S aureus infections, and 132 (17%) had nosocomial S aureus infections. 47 (6%) had meticillin-resistant infections. 301 (40%) participants had an initial deep infection focus. Standard antibiotics were given for 29 (IQR 18-45) days; 619 (82%) participants received flucloxacillin. By week 12, 62 (17%) of participants who received rifampicin versus 71 (18%) who received placebo experienced treatment failure or disease recurrence, or died (absolute risk difference -1·4%, 95% CI -7·0 to 4·3; hazard ratio 0·96, 0·68-1·35, p=0·81). From randomisation to 12 weeks, no evidence of differences in serious (p=0·17) or grade 3-4 (p=0·36) adverse events were observed; however, 63 (17%) participants in the rifampicin group versus 39 (10%) in the placebo group had antibiotic or trial drug-modifying adverse events (p=0·004), and 24 (6%) versus six (2%) had drug interactions (p=0·0005). INTERPRETATION: Adjunctive rifampicin provided no overall benefit over standard antibiotic therapy in adults with S aureus bacteraemia. FUNDING: UK National Institute for Health Research Health Technology Assessment

    Cranz-Schardin visualisation of a hypersonic cone with gas injection

    Get PDF
    We have developed a five-picture Cranz-Schardin system for Schlieren flow visualization on a gun tunnel facility at the University of Southern Queensland to aid the study of unsteady shock systems in nominally steady hypersonic flows. The system produces useful images at framing rates up to about 1 MHz even though the system development was constrained by a very modest budget. The system uses multiple LED light sources driven by an in-house designed device that delivers a high current pulse to each LED with a programmable time delay between each pulse. The images are captured using four separate, black and white video devices and one digital still camera. The utility of the system is demonstrated by imaging gas injection from an annulus on a 10 degree half angle cone positioned at the exit of the contoured Mach 7 nozzle. Visualisation of the cone without gas injection demonstrates that the half angle of the conical shock is approximately 13.9 degrees (the Taylor-Maccoll conical shock angle at Mach 7 for an inviscid cone half angle of 10 degrees is 12.9 degrees). The gas injection condition used in these experiments disturbed the flow field upstream of the injection point to such an extent that the thickness of the shocked flow at the point of injection was larger than the no-injection case by a factor of approximately two. The conical shock angle in the case of injection increased to approximately 19 degrees, and a variation in this shock angle of approximately 1 degree was observed during the nominally steady, facility run time

    Does vasospasm occur in small pial arteries and arterioles of rabbits?

    No full text

    Adjusting the paradigm: a theme-based approach to EAP

    No full text
    • …
    corecore