112 research outputs found

    Binning effects on in-situ raindrop size distribution measurements

    Get PDF
    This paper investigates the binning effects on drop size distribution (DSD) measurements obtained by Joss-Waldvogel disdrometer (JWD), Precipitation Occurrence Sensor System (POSS), Thies disdrometer (Thies), Parsivel OTT disdrometer, two-dimensional video disdrometer (2DVD) and optical spectro-pluviometer (OSP) instruments, therefore the evaluation comprises non-regular bin sizes and the effect of minimum and maximum measured sizes of drops. To achieve this goal, 2DVD measurements and simulated gamma size distributions were considered. The analysis of simulated gamma DSD binned according each instrument was performed to understand the role of discretisation and truncation effects together on the integral rainfall parameters and estimators of the DSD parameters. In addition, the drop-by-drop output of the 2DVD is binned to simulate the raw output of the other disdrometers which allowed us estimate sampling and binning effects on selected events from available dataset. From simulated DSD it has been found that binning effects exist in integral rainfall parameters and in the evaluation of DSD parameters of a gamma distribution. This study indicates that POSS and JWD exhibit underestimation of concentration and mean diameter due to binning. Thies and Parsivel report a positive bias for rainfall and reflectivity (reaching 5% for heavy rainfall intensity events). Regarding to DSD parameters, distributions of estimators for the shape and scale parameters were analyzed by moment, truncated moment and maximum likelihood methods. They reported noticeable differences between instruments for all methodologies of estimation applied. The measurements of 2DVD allow sampling error estimation of instruments with smaller capture areas than 2DVD. The results show that the instrument differences due to sampling were a~relevant uncertainty but that concentration, reflectivity and mass-weighted diameter were sensitive to binning

    Mapping spectroscopic uncertainties into prospective methane retrieval errors from Sentine-5 and its precursor

    Get PDF
    Sentinel-5 (S5) and its precursor (S5P) are future European satellite missions aiming at global monitoring of methane (CH4) column average dry air mole fractions (XCH4). The spectrometers to be deployed on-board the satellites record spectra of sunlight backscattered from the Earth\u27s surface and atmosphere. In particular, they exploit CH4 absorption in the shortwave infrared spectral range around 1.65 µm (S5 only) and 2.35 µm (both, S5 and S5P) wavelength. Given an accuracy goal of better than 2% for XCH4 to be delivered on regional scales, assessment and reduction of potential sources of systematic error such as spectroscopic uncertainties is crucial. Here, we investigate how spectroscopic errors propagate into retrieval errors on the global scale. To this end, absorption spectra of a ground-based Fourier Transform Spectrometer (FTS) operating at very high spectral resolution serve as estimate for the quality of the spectroscopic parameters. Feeding the FTS fitting residuals as a perturbation into a global ensemble of simulated S5 and S5P-like spectra at relatively low spectral resolution, XCH4 retrieval errors exceed 1% in large parts of the world and show systematic correlations on regional scales, calling for improved spectroscopic parameters

    Mapping spectroscopic uncertainties into prospective methane retrieval errors from Sentine-5 and its precursor

    Get PDF
    Sentinel-5 (S5) and its precursor (S5P) are future European satellite missions aiming at global monitoring of methane (CH4) column average dry air mole fractions (XCH4). The spectrometers to be deployed on-board the satellites record spectra of sunlight backscattered from the Earth\u27s surface and atmosphere. In particular, they exploit CH4 absorption in the shortwave infrared spectral range around 1.65 µm (S5 only) and 2.35 µm (both, S5 and S5P) wavelength. Given an accuracy goal of better than 2% for XCH4 to be delivered on regional scales, assessment and reduction of potential sources of systematic error such as spectroscopic uncertainties is crucial. Here, we investigate how spectroscopic errors propagate into retrieval errors on the global scale. To this end, absorption spectra of a ground-based Fourier Transform Spectrometer (FTS) operating at very high spectral resolution serve as estimate for the quality of the spectroscopic parameters. Feeding the FTS fitting residuals as a perturbation into a global ensemble of simulated S5 and S5P-like spectra at relatively low spectral resolution, XCH4 retrieval errors exceed 1% in large parts of the world and show systematic correlations on regional scales, calling for improved spectroscopic parameters

    Geostationary Emission Explorer for Europe (G3E): mission concept and initial performance assessment

    Get PDF
    The Geostationary Emission Explorer for Europe (G3E) is a concept for a geostationary satellite sounder that targets at constraining the sources and sinks of the greenhouse gases carbon dioxide (CO2) and methane (CH4) for continental-scale regions. Thereby, its primary focus is on Central Europe. G3E carries a spectrometer system that collects sunlight backscattered from the Earth\u27s surface and atmosphere in the near-infrared (NIR) and shortwave-infrared (SWIR) spectral range. Solar absorption spectra allow for spatiotemporally dense observations of the column-average concentrations of carbon dioxide (XCO2), methane (XCH4), and carbon monoxide (XCO) including sampling of the diurnal variation with several measurements per day during summer. Here, we present the mission concept and carry out an initial performance assessment of the retrieval capabilities. The radiometric performance of the 4 grating spectrometers is tuned to reconcile small ground-pixel sizes (~ 2 km × 3 km at 50° latitude) with short single-shot exposures (∼ 2.9 s) that allow for sampling continental regions such as Central Europe within 2 h while providing sufficient signal-to-noise. The noise errors to be expected for XCO2, XCH4, and XCO are assessed through retrieval simulations for a European trial ensemble. Generally, single-shot precision for the targeted XCO2 and XCH4 is better than 0.5 % with some exception for scenes with low infrared surface albedo observed under low sun conditions in winter. For XCO, precision is generally better than 10 %. Performance for aerosol and cirrus loaded atmospheres is assessed by mimicking G3E\u27s slant view on Europe for an ensemble of atmospheric scattering properties used previously for evaluating nadir-viewing low-Earth-orbit (LEO) satellites. While retrieval concepts developed for LEO configurations generally succeed in mitigating aerosol and cirrus induced retrieval errors for G3E\u27s setup, residual errors are somewhat greater in geostationary orbit (GEO) than in LEO. G3E\u27s deployment in the vicinity of the Meteosat Third Generation (MTG) satellites suggests making synergistic use of MTG\u27s sounding capabilities e.g. with respect to characterization of aerosol and cloud properties or with respect to enhancing carbon monoxide retrievals by combining G3E\u27s solar and MTG\u27s thermal infrared spectra

    Geostationary Emission Explorer for Europe (G3E): mission concept and initial performance assessment

    Get PDF
    The Geostationary Emission Explorer for Europe (G3E) is a concept for a geostationary satellite sounder that aims to constrain the sources and sinks of greenhouse gases carbon dioxide (CO2) and methane (CH4) for continental-scale regions. Its primary focus is on central Europe. G3E carries a spectrometer system that collects sunlight backscattered from the Earth\u27s surface and atmosphere in the near-infrared (NIR) and shortwave-infrared (SWIR) spectral range. Solar absorption spectra allow for spatiotemporally dense observations of the column-average concentrations of carbon dioxide (XCO2), methane (XCH4), and carbon monoxide (XCO). The mission concept in particular facilitates sampling of the diurnal variation with several measurements per day during summer. Here, we present the mission concept and carry out an initial performance assessment of the retrieval capabilities. The radiometric performance of the 4 grating spectrometers is tuned to reconcile small ground-pixel sizes (~2 km × 3 km at 50° latitude) with short single-shot exposures (~2.9 s) that allow for sampling continental regions such as central Europe within 2 h while providing a sufficient signal-to-noise ratio. The noise errors to be expected for XCO2, XCH4, and XCO are assessed through retrieval simulations for a European trial ensemble. Generally, single-shot precision for the targeted XCO2 and XCH4 is better than 0.5 % with some exception for scenes with low infrared surface albedo observed under low sun conditions in winter. For XCO, precision is generally better than 10 %. Performance for aerosol and cirrus loaded atmospheres is assessed by mimicking G3E\u27s slant view on Europe for an ensemble of atmospheric scattering properties used previously for evaluating nadir-viewing low-Earth-orbit (LEO) satellites. While retrieval concepts developed for LEO configurations generally succeed in mitigating aerosol- and cirrus-induced retrieval errors for G3E\u27s setup, residual errors are somewhat greater in geostationary orbit (GEO) than in LEO. G3E\u27s deployment in the vicinity of the Meteosat Third Generation (MTG) satellites has the potential to make synergistic use of MTG\u27s sounding capabilities e.g. with respect to characterization of aerosol and cloud properties or with respect to enhancing carbon monoxide retrievals by combining G3E\u27s solar and MTG\u27s thermal infrared spectra

    Impact of Liver Inflammation on Bile Acid Side Chain Shortening and Amidation

    Get PDF
    Bile acid (BA) synthesis from cholesterol by hepatocytes is inhibited by inflammatory cytokines. Whether liver inflammation also affects BA side chain shortening and conjugation was investigated. In human liver cell lines (IHH, HepG2, and HepaRG), agonists of nuclear receptors including the farnesoid X receptor (FXR), liver X receptor (LXR), and peroxisome proliferator-activated receptors (PPARs) did not affect the expression of BA-related peroxisomal enzymes. In contrast, hepatocyte nuclear factor 4? (HNF4?) inhibition down-regulated acyl-CoA oxidase 2 (ACOX2). ACOX2 was repressed by fibroblast growth factor 19 (FGF19), which was prevented by extracellular signal-regulated kinase (ERK) pathway inhibition. These changes were paralleled by altered BA synthesis (HPLC-MS/MS). Cytokines able to down-regulate cholesterol-7?-hydroxylase (CYP7A1) had little effect on peroxisomal enzymes involved in BA synthesis except for ACOX2 and bile acid-CoA:amino acid N-acyltransferase (BAAT), which were down-regulated, mainly by oncostatin M (OSM). This effect was prevented by Janus kinase (JAK) inhibition, which restored BA side chain shortening and conjugation. The binding of OSM to the extracellular matrix accounted for a persistent effect after culture medium replacement. In silico analysis of four databases (n = 201) and a validation cohort (n = 90) revealed an inverse relationship between liver inflammation and ACOX2/BAAT expression which was associated with changes in HNF4? levels. In conclusion, BA side chain shortening and conjugation are inhibited by inflammatory effectors. However, other mechanisms involved in BA homeostasis counterbalance any significant impact on the serum BA profile

    Clinical Usefulness Of Sars-Cov-2 Rapid Antigen Tests In Adults During High Prevalence Community Outbreaks

    Full text link
    We evaluated performance of Abbott PanBio® COVID-19 Rapid Antigen Test Device (RATD) to detect SARS-CoV-2 infection in adults during high prevalence COVID-19 outbreaks. We found high accuracy in correct diagnosis (88% CI 85-91%, p<0.05) regardless of gender, presence of symptoms, disease timeline. Test sensitivity appeared to increase with age, specificity seemed to decline. Best diagnostic accuracy was obtained in middle-aged adults (94% CI 89-97%, p<0.05), but remained high through all ages. These results support RATD as a reliable measure to determine isolation of infected individuals during outbreaks. More studies are needed to assess RATD performance in low prevalence post-vaccination scenarios.http://deepblue.lib.umich.edu/bitstream/2027.42/166596/1/AFM-177-21_PP.pdfDescription of AFM-177-21_PP.pdf : Main ArticleSEL

    Differences in pharmaceutical consumption and expenses between immigrant and Spanish-born populations in Lleida, (Spain): A 6-months prospective observational study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There are few studies comparing pharmaceutical costs and the use of medications between immigrants and the autochthonous population in Spain. The objective of this study is to evaluate whether there are differences in pharmaceutical consumption and expenses between immigrant and Spanish-born populations.</p> <p>Methods</p> <p>Prospective observational study in 1,630 immigrants and 4,154 Spanish-born individuals visited by fifteen primary care physicians at five public Primary Care Clinics (PCC) during 2005 in the city of Lleida, Catalonia (Spain). Data on pharmaceutical consumption and expenses was obtained from a comprehensive computerized data-collection system. Multinomial regression models were used to estimate relative risks and confidence intervals of pharmaceutical expenditure, adjusting for age and sex.</p> <p>Results</p> <p>The percentage of individuals that purchased medications during a six-month period was 53.7% in the immigrant group and 79.2% in the autochthonous group. Pharmaceutical expenses and consumption were lower in immigrants than in autochthonous patients in all age groups and both genders. The relative risks of being in the highest quartile of expenditure, for Spanish-born versus immigrants, were 6.9, 95% CI = (4.2, 11.5) in men and 5.3, 95% CI = (3.5, 8.0) in women, with the reference category being not having any pharmaceutical expenditure.</p> <p>Conclusion</p> <p>Pharmaceutical expenses are much lower for immigrants with respect to autochthonous patients, both in the percentage of prescriptions filled at pharmacies and the number of containers of medication obtained, as well as the prices of the medications used. Future studies should explore which factors explain the observed differences in pharmaceutical expenses and if these disparities produce health inequalities.</p
    corecore